Engineering Papers⌕ Search

Engineering topics

Ten Eyck, Gregory A

Publications and source records attributed to Ten Eyck, Gregory A.

Spectroscopy and capacitance measurements of tunneling resonances in an Sb-implanted point contact.

We fabricated a split-gate defined point contact in a double gate enhancement mode Si-MOS device, and implanted Sb donor atoms using a self-aligned process. E-beam lithography in combination with a timed implant gives us excellent control over the placement of dopant atoms, and acts as a stepping stone to focused ion beam implantation of single donors. Our approach allows us considerable latitude in experimental design in-situ. We have identified two resonance conditions in the point contact conductance as a function of split gate voltage. Using tunneling spectroscopy, we probed their electronic structure as a function of temperature and magnetic field. We also determine the capacitive coupling between the resonant feature and several gates. Comparison between experimental values and extensive quasi-classical simulations constrain the location and energy of the resonant level. We discuss our results and how they may apply to resonant tunneling through a single donor.

99 GENERAL AND MISCELLANEOUS↗

Double quantum dot with tunable coupling in a Si MOS device with lateral geometry.

We report low-temperature transport measurements of a silicon metal-oxide-semiconductor (MOS) double quantum dot (DQD). In contrast to previously reported measurements of DQD's in Si MOS structures, our device has a lateral gate geometry very similar to that used by Petta et al. to demonstrate coherent manipulation of single electron spins. This gate design provides a high degree of tunability, allowing for independent control over individual dot occupation and tunnel barriers, as well as the ability to use nearby constrictions to sense dot charge occupation. Comparison of experimentally extracted capacitances between the dot and nearby gates with electrostatic modeling demonstrates the presence of disorder and the ability to partially compensate for this disorder by adjustment of gate voltages. We experimentally show gate-controlled tuning of the interdot coupling over a wide range of energies, an important step towards potential quantum computing applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication of cubic micron-scale 3D metamaterial resonators.

We present a new fabrication technique called Membrane Projection Lithography for the production of three-dimensional metamaterials at infrared wavelengths. Using this technique, multilayer infrared metamaterials that include both in-plane and out-of-plane resonators can be fabricated.

36 MATERIALS SCIENCE↗

3D metamaterials for the thermal infrared.

Metamaterials form a new class of artificial electromagnetic materials that provides the device designer with the ability to manipulate the flow of electromagnetic energy in ways that are not achievable with naturally occurring materials. However, progress toward practical implementation of metamaterials, particularly at infrared and visible frequencies, has been hampered by a combination of absorptive losses; the narrow band nature of the resonant metamaterial response; and the difficulty in fabricating fully 3-dimensional structures. They describe the progress of a recently initiated program at Sandia National Laboratories directed toward the development of practical 3D metamaterials operating in the thermal infrared. They discuss their analysis of fundamental loss limits for different classes of metamaterials. In addition, they discuss new design approaches that they are pursuing which reduce the reliance on metallic structures in an effort to minimize ohmic losses.

36 MATERIALS SCIENCE↗

Infrared cubic dielectric resonator metamaterial.

Dielectric resonators are an effective means to realize isotropic, low-loss optical metamaterials. As proof of this concept, a cubic resonator is analytically designed and then tested in the long-wave infrared.

36 MATERIALS SCIENCE↗

Fabrication techniques for 3D metamaterials in the mid-infrared.

The authors have developed two versions of a flexible fabrication technique known as membrane projection lithography that can produce nearly arbitrary patterns in '212 D' and fully three-dimensional (3D) structures. The authors have applied this new technique to the fabrication of split ring resonator-based metamaterials in the midinfrared. The technique utilizes electron beam lithography for resolution, pattern design flexibility, and alignment. The resulting structures are nearly three orders of magnitude smaller than equivalent microwave structures that were first used to demonstrate a negative index material. The fully 3D structures are highly isotropic and exhibit both electrically and magnetically excited resonances for incident transverse electromagnetic waves.

36 MATERIALS SCIENCE↗

Fabrication of 3-D cubic unit cells with measured IR resonances.

3-D cubic unit cell arrays containing split ring resonators were fabricated and characterized. The unit cells are {approx}3 orders-of-magnitude smaller than microwave SRR-based metamaterials and exhibit both electrically and magnetically excited resonances for normally incident TEM waves in addition to showing improved isotropic response.

36 MATERIALS SCIENCE↗

Strained-Si/SiGe enhancement mode structures for quantum computing.

Silicon is an ideal system for investigating single electron or isolated donor spins for quantum computation, due to long spin coherence times. Enhancement mode strained-silicon/silicon germanium (sSi/SiGe) devices would offer an as-yet untried path toward electron or electron/donor quantum dot systems. Thin, undoped SiGe dielectrics allow tight electrostatic confinement, as well as potential Lande g-factor engineered spin manipulation. In this talk we summarize recent progress toward sSi/SiGe enhancement mode devices on sSi on insulator, including characterization with X-ray diffraction and atomic force microscopy, as well as challenges faced and progress on integration of either top-down and bottom-up donor placement approaches in a sSi/SiGe enhancement mode structure.

36 MATERIALS SCIENCE↗

Amplitude and phase-resolved measurements of optical metamaterials in the mid-infrared by phase matched electro-optic sampling.

We describe a time-domain spectroscopy system in the thermal infrared used for complete transmission and reflection characterization of metamaterials in amplitude and phase. The system uses a triple-output near-infrared ultrafast fiber laser, phase-locked difference frequency generation and phase-matched electro-optic sampling. We will present measurements of several metamaterials designs.

36 MATERIALS SCIENCE↗

Electrostatic microvalves utilizing conductive nanoparticles for improved speed, lower power, and higher force actuation.

We have designed and built electrostatically actuated microvalves compatible with integration into a PDMS based microfluidic system. The key innovation for electrostatic actuation was the incorporation of carbon nanotubes into the PDMS valve membrane, allowing for electrostatic charging of the PDMS layer and subsequent discharging, while still allowing for significant distention of the valveseat for low voltage control of the system. Nanoparticles were applied to semi-cured PDMS using a stamp transfer method, and then cured fully to make the valve seats. DC actuation in air of these valves yielded operational voltages as low as 15V, by using a supporting structure above the valve seat that allowed sufficient restoring forces to be applied while not enhancing actuation forces to raise the valve actuation potential. Both actuate to open and actuate to close valves have been demonstrated, and integrated into a microfluidic platform, and demonstrated fluidic control using electrostatic valves.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Medically relevant ElectroNeedle technology development.

ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

30 DIRECT ENERGY CONVERSION↗