Engineering PapersSearch

Engineering topics

Taylor, J. R.

Publications and source records attributed to Taylor, J. R..

Ionospheric convection during the magnetic storm of 20-21 March 1991

We report on the response of high-latitude ionospheric convection during the magnetic storm of March 20-21 1990. IMP-8 measurements of solar wind plasma and interplanetary magnetic field (IMF), ionospheric convection flow measurements from the Wick and Goose Bay coherent radars, EISCAT, Millstone Hill and Sondrestorm incoherent radars and three digisondes at Millstone Hill, Goose Bay and Qaanaaq are presented. Two intervals of particular interest have been indentified. The first starts with a storm sudden commencement at 2243 UT on March 20 and includes the ionospheric activity in the following 7 h. The response time of the ionospheric convection to the southward tuning of the IMF in the dusk to midnight local times is found to be approximately half that measured in a similar study at comparable local times during more normal solar wind conditions. A subsequent reconfiguration of the nightside convection pattern was also observed, although it was not possible to distinguish between effects due to possible changes in B(sub y) and effects due to substorm activity. The second interval, 1200-2100 UT 21 March 1990, included a southward turning of the IMF which resulted in the B(sub z) component becoming -10 nT. The response time on the dayside to this change in the IMF at the magnetopause was approximately 15 min to 30 min which is a factor of approximately 2 greater than those previously measured at higher latitudes. A movement of the nightside flow reversal, possibly driven by current systems associated with the substorm expansion phases, was observed, implying that the nightside convection pattern can be dominated by substorm activity.

Taylor, J. R.

Flow modifying device

A swirler for a gas turbine engine combustor is disclosed for simultaneously controlling combustor flow rate, swirl angle, residence time and fuel-air ratio to provide three regimes of operation. A first regime is provided in which fuel-air ratio is less than stoichiometric, NOx is produced at one level, and combustor flow rate is high. In a second regime, fuel-air ratio is nearly stoichiometric, NOx production is less than that of the first regime, and combustor flow rate is low. In a third regime, used for example at highoff, fuel-air ratio is greater than stoichiometric and the combustor flow rate is less than in either of the other regimes.

Kelm, J. S.

Energy Efficient Engine (E3) combustion system component technology performance report

The Energy Efficient Engine (E3) combustor effort was conducted as part of the overall NASA/GE E3 Program. This effort included the selection of an advanced double-annular combustion system design. The primary intent of this effort was to evolve a design that meets the stringent emissions and life goals of the E3, as well as all of the usual performance requirements of combustion systems for modern turbofan engines. Numerous detailed design studies were conducted to define the features of the combustion system design. Development test hardware was fabricated, and an extensive testing effort was undertaken to evaluate the combustion system subcomponents in order to verify and refine the design. Technology derived from this effort was incorporated into the engine combustion hardware design. The advanced engine combustion system was then evaluated in component testing to verify the design intent. What evolved from this effort was an advanced combustion system capable of satisfying all of the combustion system design objectives and requirements of the E3.

Burrus, D. L.

Energy Efficient Engine combustor test hardware detailed design report

The Energy Efficient Engine (E3) Combustor Development effort was conducted as part of the overall NASA/GE E3 Program. This effort included the selection of an advanced double-annular combustion system design. The primary intent was to evolve a design which meets the stringent emissions and life goals of the E3 as well as all of the usual performance requirements of combustion systems for modern turbofan engines. Numerous detailed design studies were conducted to define the features of the combustion system design. Development test hardware was fabricated, and an extensive testing effort was undertaken to evaluate the combustion system subcomponents in order to verify and refine the design. Technology derived from this development effort will be incorporated into the engine combustion system hardware design. This advanced engine combustion system will then be evaluated in component testing to verify the design intent. What is evolving from this development effort is an advanced combustion system capable of satisfying all of the combustion system design objectives and requirements of the E3. Fuel nozzle, diffuser, starting, and emissions design studies are discussed.

Burrus, D. L.

Design and development of the combustor inlet diffuser for the NASA/GE energy efficient engine

Results of an experimental investigation of the aerodynamic performance of a split duct annular combustor inlet diffuser system are presented. Several diffuser configurations were investigated in 3X-scale water table tests and the preferred design was evaluated in full-scale annular airflow model tests. Pressure recovery and flow losses were determined as a function of prediffuser inlet velocity profile, flow extraction at the prediffuser exit, and distribution of flow in the combustor. Inlet velocity profile and turbulence levels were found to have a pronounced effect on system performance. Flow extraction at the prediffuser exit was found to have little influence on system performance. Generally, the annular split duct diffuser system was found to satisfy the performance objectives for the engine.

Sabla, P. E.

Analytical evaluation of the impact of broad specification fuels on high bypass turbofan engine combustors

Six conceptual combustor designs for the CF6-50 high bypass turbofan engine and six conceptual combustor designs for the NASA/GE E3 high bypass turbofan engine were analyzed to provide an assessment of the major problems anticipated in using broad specification fuels in these aircraft engine combustion systems. Each of the conceptual combustor designs, which are representative of both state-of-the-art and advanced state-of-the-art combustion systems, was analyzed to estimate combustor performance, durability, and pollutant emissions when using commercial Jet A aviation fuel and when using experimental referee board specification fuel. Results indicate that lean burning, low emissions double annular combustor concepts can accommodate a wide range of fuel properties without a serious deterioration of performance or durability. However, rich burning, single annular concepts would be less tolerant to a relaxation of fuel properties. As the fuel specifications are relaxed, autoignition delay time becomes much smaller which presents a serious design and development problem for premixing-prevaporizing combustion system concepts.

Taylor, J. R.

Turbulence measurements in the compressor exit flow of a General Electric CF6-50 engine

Ruggedized cooled film probes were used to measure CF6-50 compressor exit turbulence properties at three different engine idle condition test points. The turbulence probe was coupled to a constant temperature anemometer and signal conditioning system. An on-line readout system connected to the anemometer was used to check the data as it was acquired. At engine idle conditions, the turbulence intensity ranged from 4.8 percent to 5.6 percent and the length scale ranged from 5.64 cm to 6.95 cm. The length scale values are somewhat larger than the passage height at the measurement plane (5.54 cm), which indicates that the shape of the turbulent eddies are elongated in the axial direction. The microscale values range from about 0.73 cm to about 0.98 cm. Power spectral density distributions show that a large proportion of the turbulent energy at the measurement plane is concentrated at frequencies below one kilohertz.

Taylor, J. R.

Experimental clean combustor program: Phase 3: Turbulence measurement addendum

Airflow turbulence parameters were measured in the high pressure, high temperature flow stream leaving the compressor of an operating gas turbine engine. A water cooled hot film turbulence probe was used to determine the turbulence intensity and length scale in the compressor exit flow stream of the CF6-50 engine. Data were obtained only at idle operating conditions. At engine power levels above idle conditions, durability problems and erratic data readings were encountered with the turbulence measurement probes. Turbulence measurements were made at three radial immersions at a point 15.5 cm downstream of the compressor outlet guide vanes in the compressor exit diffuser. The passage height at this point is 5.54 cm. Data reduction was accomplished with a time-data fast Fourier transform (FFT) system. This system finds the power spectral density distribution (PSD) of a large number of data samples using a direct Fourier transform algorithm and finds the autocorrelation parameter for these data by doing an FFT analysis of the PSD curves for a series of time delay intervals.

Taylor, J. R.

Miniature diaphragm valve for medical equipment

Valve assembly keeps nutrient out of moving parts of valve by physically isolating plunger from fluid. Poppet and diaphragm are molded together, and latter is shaped to act as static seal, which remains seated during the operation. As plunger moves, diaphragm also moves to form separate cavity for nutrient and thus isolates it from plunger cavity and latching mechanism.

Stadler, T. J.