Engineering Papers⌕ Search

Engineering topics

Tarbell, T. D.

Publications and source records attributed to Tarbell, T. D..

31 records · Page 2

White light sunspot observations from the Solar Optical Universal Polarimeter on Spacelab-2

The flight of the Solar Optical Universal Polarimeter on Spacelab-2 provided the opportunity for the collection of time sequences of diffraction-limited (0.5 arcsec) solar images with excellent pointing stability (0.003 arcsec) and with freedom from the distortion that plagues ground-based images. A series of white-light images of active region 4682 were obtained on August 5, 1985, and the area containing the sunspot has been analyzed. These data have been digitally processed to remove noise and to separate waves from low-velocity material motions. The results include: (1) proper motion measurements of a radial outflow in the photospheric granulation pattern just outside the penumbra; (2) discovery of occasional bright structures ('streakers') that appear to be ejected outward from the penumbra; (3) broad dark 'clouds' moving outward in the penumbra, in addition to the well-known bright penumbral grains moving inward; (4) apparent extensions and contractions of penumbral filaments over the photosphere; and (5) observation of a faint bubble or looplike structure that seems to expand from two bright penumbral filaments into the photosphere.

Shine, R. A.↗

First results on quiet and magnetic granulation from SOUP

The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.

Title, A. M.↗

Large-scale horizontal flows from SOUP observations of solar granulation

Using high resolution time sequence photographs of solar granulation from the SOUP experiment on Spacelab 2, large scale horizontal flows were observed in the solar surface. The measurement method is based upon a local spatial cross correlation analysis. The horizontal motions have amplitudes in the range 300 to 1000 m/s. Radial outflow of granulation from a sunspot penumbra into surrounding photosphere is a striking new discovery. Both the supergranulation pattern and cellular structures having the scale of mesogranulation are seen. The vertical flows that are inferred by continuity of mass from these observed horizontal flows have larger upflow amplitudes in cell centers than downflow amplitudes at cell boundaries.

November, L. J.↗

Sunspot observations from the SOUP instrument on Spacelab 2

A series of white light images obtained by the SOUP instrument on Spacelab 2 of active region 4682 on August 5, 1985 were analyzed in the area containing sunspots. Although the umbra of the spot is underexposed, the film is well exposed in the penumbral regions. These data were digitally processed to remove noise and to separate p-mode oscillations from low velocity material motions. The results of this preliminary investigation include: (1) proper motion measurements of a radial outflow in the photospheric granulation pattern just outside the penumbra; (2) discovery of occasional bright structures (streakers) that appear to be ejected outward from the penumbra; (3) broad dark clouds moving outward in the penumbra in addition to the well known bright penumbral grains moving inward; (4) apparent extensions and contractions of penumbral filaments over the photosphere; and (5) observation of a faint bubble or loop-like structure which seems to expand from two bright penumbral filaments into the photosphere.

Shine, R. A.↗

White-light movies of the solar photosphere from the SOUP instrument on Spacelab

Initial results are presented on solar granulation, pores and sunspots from the white-light films obtained by the Solar Optical Universal Polarimeter (SOUP) instrument in Spacelab 2. Several hours of movies were taken at various disk and limb positions in quiet and active regions. The images are diffraction-limited at 0.5 arcsec resolution and are, of course, free of atmospheric seeing and distortion. Properties of the granulation in magnetic and nonmagnetic regions are compared and are found to differ significantly in size, rate of intensity variation, and lifetime. In quiet sun, on the order of fifty-percent of the area has at least one 'exploding granule' occurring in it during a 25-min period. Local correlation tracking has detected several types of transverse flows, including systematic outflow from the penumbral boundary of a spot, motion of penumbral filaments, and cellular flow patterns of supergranular and mesogranular size. Feature tracking has shown that, in the quiet sun, the average granule fragment has a velocity of about one kilometer/second.

Title, A. M.↗

Low noise imaging photon counter for astronomy

The characteristics and performance of a Ranicon photon-counting system combined with digital tape recording are described. The most important features are a bialkali photocathode response over 256 X 256 digital pixels, with approximately 100 X 100 resolvable pixels at 50% MTF, a dead time of 16 microsec/count, a maximum recordable count rate of 14,400/sec, and a background of less than 1 count/digital pixel/h. A video cassette recorder serves for the digital recording which retains the temporal sequence of the registered photons. Astronomical applications will include low light level quantitative imaging and speckle imaging.

Mertz, L.↗

Image motion compensation on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

The SOUP experiment on Spacelab 2 includes a 30 cm visible light telescope and focal plane package mounted on the Instrument Pointing System (IPS). Scientific goals of the experiment dictate pointing stability requirements of less than 0.05 arcsecond jitter over periods of 5-20 seconds. Quantitative derivations of these requirements from two different aspects are presented: (1) avoidance of motion blurring of diffraction-limited images; (2) precise coalignment of consecutive frames to allow measurement of small image differences. To achieve this stability, a fine guider system capable of removing residual jitter of the IPS and image motions generated on the IPS cruciform instrument support structure has been constructed. This system uses solar limb detectors in the prime focal plane to derive an error signal. Image motion due to pointing errors is compensated by the agile secondary mirror mounted on piezoelectric transducers, controlled by a closed-loop servo system.

Tarbell, T. D.↗

Video image processor on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

The SOUP instrument is designed to obtain diffraction-limited digital images of the sun with high photometric accuracy. The Video Processor originated from the requirement to provide onboard real-time image processing, both to reduce the telemetry rate and to provide meaningful video displays of scientific data to the payload crew. This original concept has evolved into a versatile digital processing system with a multitude of other uses in the SOUP program. The central element in the Video Processor design is a 16-bit central processing unit based on 2900 family bipolar bit-slice devices. All arithmetic, logical and I/O operations are under control of microprograms, stored in programmable read-only memory and initiated by commands from the LSI-11. Several functions of the Video Processor are described, including interface to the High Rate Multiplexer downlink, cosmetic and scientific data processing, scan conversion for crew displays, focus and exposure testing, and use as ground support equipment.

Lindgren, R. W.↗

Spacelab data analysis and interactive control study

The study consisted of two main tasks, a series of interviews of Spacelab users and a survey of data processing and display equipment. Findings from the user interviews on questions of interactive control, downlink data formats, and Spacelab computer software development are presented. Equipment for quick look processing and display of scientific data in the Spacelab Payload Operations Control Center (POCC) was surveyed. Results of this survey effort are discussed in detail, along with recommendations for NASA development of several specific display systems which meet common requirements of many Spacelab experiments.

Tarbell, T. D.↗

Correlation tracking study for meter-class solar telescope on space shuttle

The theory and expected performance level of correlation trackers used to control the pointing of a solar telescope in space using white light granulation as a target were studied. Three specific trackers were modeled and their performance levels predicted for telescopes of various apertures. The performance of the computer model trackers on computer enhanced granulation photographs was evaluated. Parametric equations for predicting tracker performance are presented.

Smithson, R. C.↗

Measurements of magnetic fluxes and field strengths in the photospheric network

Digital pictures of an active-region network cell are presented in five quantities measured simultaneously: continuum intensity, line-center intensity, equivalent width, magnetogram signal, and magnetic-field strength. These maps are derived from computer analysis of circularly polarized line profiles of Fe I 5250.2-A; spectral and spatial resolution are 1/40 A and 1.5 arcsec, respectively. Measured Zeeman splittings show the existence of strong magnetic fields (1000-1800 G) at nearly all points with a magnetogram signal exceeding 125 G. The mean and rms deviation of the field strengths change by less than 20% over a factor-of-four range of fluxes. From the significant disparity between measured fluxes and field strengths, it is concluded that large flux patches (up to 4 arcsec across) consist of closely-packed unresolved filaments. The smallest filaments must be less than 0.7 arcsec in diameter. The dark component of the photospheric network, which appears to contain sizable transverse fields, is also observed.

Tarbell, T. D.↗

Measurements of solar magnetic fields by Fourier transform techniques. II - Saturated and blended lines

Fourier techniques have been exhaustively calibrated using Unno's (1956) results for the absorption profile of a simple Zeeman triplet. If a simple transformation is applied to the normalized line depths, then magnetic-field strengths and inclination angles can be measured very accurately from noisy saturated line profiles. Systematic errors caused by saturation effects can be estimated and reduced by varying one parameter. When a significant fraction of the line profile is unsplit and unpolarized, large errors may be made in measurements of low fields, unless the line is sufficiently weak. For a weak line, a vertical field of 1600 gauss can be measured to 10% accuracy even when 70% of the line profile is stray light. These stray-light errors are troublesome in measuring fields of gaps and pores but not sunspots. Numerical results of the error analysis are presented graphically.

Tarbell, T. D.↗

Measurements of solar magnetic fields by Fourier transform techniques. I - Unsaturated lines

If the basic profile shapes of the normal Zeeman triplet do not have zeros in their Fourier transform, the magnetic field splitting can be determined independent of the profile shape. When the ratio of the splitting of the components is greater than the intrinsic FWHM of the component profiles, the magnetic splitting can be determined with significantly greater accuracy than the measurement accuracy of the original profile. For Gaussian shaped components and a ratio of magnetic splitting to FWHM of 1.5, the noise reduction factor is 25.

Title, A. M.↗