Engineering Papers⌕ Search

Engineering topics

Tandon, Lav

Publications and source records attributed to Tandon, Lav.

At least 19 records

Container Evaluation: Analysis of the Swagelok Knuckle with Viewport as an Approved Hermetically Sealed Inner Container

This report outlines the results from the water ingress test, helium leak test and additional atmosphere testing for the Swagelok knuckle with viewport container further referred to as the SKV. This container is constructed from a standard union vacuum fitting, 1.33” conflat to 0.5” male VCR, a 1.33” conflat fused silica lensed viewport fitting, and a 0.5 inch VCR cap. The primary intended use of this container is to store Pu metal samples in the vault for a time interval exceeding 40 years. The samples need to be contained in an air free environment to ensure that the material does not oxidize over time. The container viewport is a critical design feature that will help the operators visually inspect and evaluate the state of the metal samples prior to opening the container. These containers are advertised as leak tight, but experimental tests were performed to test the water resistant criteria and the gas leaking criteria set forth by the TA-55 Criticality Safety Program. The results of the water ingress test show that the container is water-tight, with no signs of water penetrating the container within the required guidelines outlined in TA55-AP-522. The preliminary He leak test performed demonstrate that the conflat window port and VCR cap are able to maintain a hermetic seal. Additionally, all containers will be He leak tested independently by the manufacturer prior to shipping to LANL. A third voluntary test was added to assess the container’s ability to hold atmosphere, with successful results indicating the container is able to hold inert atmosphere to prevent lanthanum metal oxidation. It is the conclusion of the authorsthat there is enough evidence through the test conducted and outlined within this document that the proposed container meets the definition of a water-tight container, and it is able to provide a hermetic seal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actinide Analytical Chemistry Overview: ICP Trace Element Analysis (Including U, Np) [Slides]

Actinide Analytical Chemistry (C-AAC) at LANL has a full set of analytical chemistry capabilities to support the production mission. AAC uses the Pu Metal Standards Exchange Program to validate and verify that the data quality objectives are met for Pu Sustainment. This presentation describes: analytical chemistry techniques used to address requirements, analytical sample flow, and process overview.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New reference materials for trace-levels of actinide elements in plutonium

In this report two plutonium oxides were prepared as unique reference materials for measurement of actinide elements present as trace constituents. Each reference material unit is approximately 200 mg of PuO 2 powder in a quartz glass bottle. Characterized attributes of the oxides included mass fractions of plutonium, americium, neptunium, and uranium. Isotope-amount ratios were also determined for plutonium and uranium, but neptunium and americium were observed to be monoisotopic 237 Np and 241 Am. Measurements for characterization and verification of the attributes show that plutonium and trace actinides are homogeneous with the exception of limited heterogeneity for uranium, primarily observed for the 238 U isotope. Model purification ages calculated from measured americium and uranium attribute values are consistent with material histories and indicate that these impurities are predominantly due to the decay of plutonium isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

X-ray diffraction, differential scanning calorimetry and evolved gas analysis of aged plutonium tetrafluoride (PuF4)

A 30 year-old PuF4 sample consisting of brown powder (PuF4-b) and pink granules (PuF4-p) was analyzed. X-ray difraction shows the bulk is comprised of three compounds: PuF4, PuO2, and PuF4·1.6H2O. Broadening of PuF4 XRD peaks suggests possible a-damage. After annealing at 650 °C, crystalline PuF4 and PuO2 remain. Thermogravimetric analysis and diferential scanning calorimetry—with simultaneous evolved gas analysis—of the separated PuF4-p and PuF4-b components reveal a distinct sequence of reactions. Dehydration occurs between~90 and 300 °C. Exothermic annealing of the a-damage occurs in two stages: at 350–355 °C and at 555–558 °C. Hydrofuoric acid, fuorine and helium desorb during the frst exotherm. Above 700 °C, PuF4 reacts with PuO2, resulting in oxygen release and mass loss.

PuF4, dsc, differential scanning calorimetry, plut↗

Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions

In this article, an intercomparison of the radio-chronometric ages of four distinct plutonium-certified reference materials varying in chemical form, isotopic composition, and period of production are presented. The cross-comparison of the different 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages obtained at four independent analytical facilities covering a range of laboratory environments from bulk sample processing to clean facilities dedicated to nuclear forensic investigation of environmental samples enables a true assessment of the state-of-practice in “age dating capabilities” for nuclear materials. The analytical techniques evaluated used modern mass spectrometer instrumentation including thermal ionization mass spectrometers and inductively coupled plasma mass spectrometers for isotopic abundance measurements. Both multicollector and single collector instruments were utilized to generate the data presented here. Consensus values established in this study make it possible to use these isotopic standards as quality control standards for radio-chronometry applications. Results highlight the need for plutonium isotopic standards that are certified for 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages as well as other multigenerational radio-chronometers such as 237 Np/ 241 Pu. Due to the capabilities of modern analytical instrumentation, analytical laboratories that focus on trace level analyses can obtain model ages with marginally larger uncertainties than laboratories that handle bulk samples. Lastly, when isotope ratio measurement techniques like thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry with comparable precision are utilized, model purification ages with similar uncertainties are obtained.

36 MATERIALS SCIENCE↗

Analytical chemistry of nuclear material: case studies from Los Alamos National Laboratory

Presented here are three case studies that demonstrate the breadth of bulk actinide analytical chemistry at Los Alamos National Laboratory (LANL). This laboratory was established during the Manhattan Project and is still considered one of the premier analytical laboratories for special nuclear materials characterization around the globe. First, the analytical chemistry of 238 Pu is presented, showcasing the unique challenges of this high activity isotope. Next, the analysis of 241 AmO 2 is discussed from the perspective of supporting nascent production at LANL. Finally, the analytical chemistry support of the production of plutonium non-destructive assay standards is discussed. Furthermore these examples paint a picture of the analytical capabilities needed to meet the dynamic challenges of LANL’s nuclear programs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The application of radiochronometry during the 4th collaborative materials exercise of the nuclear forensics international technical working group (ITWG) [Radiochronometry in the CMX-4 exercise]

In a recent international exercise, 10 international nuclear forensics laboratories successfully performed radiochronometry on three low enriched uranium oxide samples, providing 12 analytical results using three different parent-daughter pairs serving as independent chronometers. The vast majority of the results were consistent with one another and consistent with the known processing history of the materials. In general, for these particular samples, mass spectrometry gave more accurate and more precise analytical results than decay counting measurements. Additionally, the concordance of the 235 U– 231 Pa and 234 U– 230 Th chronometers confirmed the validity of the age dating assumptions, increasing confidence in the resulting conclusions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing Diagnostic Tools for Low-Burnup Reactor Samples

We test common neutron fluence diagnostics in the very-low-burnup regime for natural uranium reactor samples. The fluence diagnostics considered are the uranium isotopics ratios 235 U / 238 U and 236 U/ 235 U, for which we find that simple analytic formulas agree well with full reactor simulation predictions. Both ratios agree reasonably well with one another for fluences in the (mid -10 19 ) - n/cm 2 range. However, below about 10 19 n/cm 2 , the concentrations of 236 U are found to be sufficiently low that the measured 236 U/ 235 U ratios become unreliable. We also derive and test diagnostics to determine the cooling times in situations where very low burnup and very long cooling times render many standard diagnostics impractical, such as the 241 Am / 241 Pu ratio. Here, we find that using several fragment ratios is necessary to detect the presence of systematic errors such as fractionation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

AmO 2 Analysis for Analytical Method Testing and Assessment: Analysis Support for AmO 2 Production

Americium oxide samples will be measured for various analytes to support AmO 2 production. The key analytes that are currently requested by the Am production customer at LANL include total Am content, Am isotopics, Pu assay, Pu isotopics, and trace element content including 237 Np content. Multiple analytical methods will be utilized depending on the sensitivity, accuracy and precision needs of the Am matrix. Traceability to the National Institute of Standards and Technology (NIST) will be achieved, where applicable, by running NIST traceable quality control materials. This given that there are no suitable AmO 2 reference materials currently available for requested analytes. The primary objective is to demonstrate the suitability of actinide analytical chemistry methods to support AmO 2 production operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty in the use of MAMA software to measure particle morphological parameters from SEM images

The MAMA software package developed at LANL is designed to make morphological measurements on a wide variety of digital images of objects. At LANL, we have focused on using MAMA to measure scanning electron microscope (SEM) images of particles, as this is a critical part of our forensic analysis of interdicted radiologic materials. In order to successfully use MAMA to make such measurements, we must understand the level of uncertainty involved in the process, so that we can rigorously support our quantitative conclusions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of origin and intended use of plutonium metal using nuclear forensic techniques

Nuclear forensics techniques, including micro-XRF, gamma spectrometry, trace elemental analysis and isotopic/chronometric characterization were used to interrogate two, potentially related plutonium metal foils. These samples were submitted for analysis with only limited production information, and a comprehensive suite of forensic analyses were performed. Resulting analytical data was paired with available reactor model and historical information to provide insight into the materials’ properties, origins, and likely intended uses. Both were super-grade plutonium, containing less than 3% 240 Pu, and age-dating suggested that most recent chemical purification occurred in 1948 and 1955 for the respective metals. Additional consideration of reactor modelling feedback and trace elemental observables indicate plausible U.S. reactor origin associated with the Hanford site production efforts. In conclusion, based on this investigation, the most likely intended use for these plutonium foils was 239 Pu fission foil targets for physics experiments, such as cross-section measurements, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical investigation of three plutonium–beryllium neutron sources

Thorough physical and chemical characterization of plutonium–beryllium (PuBe) neutron sources is an important capability with applications ranging from material accountancy to nuclear forensics. Furthermore, characterization of PuBe sources is not trivial owing to range of existing source designs and the need for adequate infrastructure to deal with radiation and protect the analyst. Our study demonstrates a method for characterization of three PuBe sources that includes physical inspection and imaging followed by controlled disassembly and destructive analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Forensic investigation of plutonium metal: a case study of CRM 126

In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical Need for Plutonium and Uranium Isotopic Standards with Lower Uncertainties

Certified reference materials (CRMs) traceable to national and international safeguards database are a critical prerequisite for ensuring that nuclear measurement systems are free of systematic biases. CRMs are used to validate measurement processes associated with nuclear analytical laboratories. Diverse areas related to nuclear safeguards are impacted by the quality of the CRM standards available to analytical laboratories. These include: nuclear forensics, radio-chronometry, national and international safeguards, stockpile stewardship, nuclear weapons infrastructure and nonproliferation, fuel fabrication, waste processing, radiation protection, and environmental monitoring. For the past three decades the nuclear community is confronted with the strange situation that improvements in measurement data quality resulting from the improved accuracy and precision achievable with modern multi-collector mass spectrometers could not be fully exploited due to large uncertainties associated with CRMs available from New Brunswick Laboratory (NBL) that are used for instrument calibration and measurement control. Similar conditions prevail for both plutonium and uranium isotopic standards and for impurity element standards in uranium matrices. Herein, the current status of U and Pu isotopic standards available from NBL is reviewed. Critical areas requiring improvement in the quality of the nuclear standards to enable the U. S. and international safeguards community to utilize the full potential of modern multi-collector mass spectrometer instruments are highlighted.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Keeping the Momentum and Nuclear Forensics at Los Alamos National Laboratory

LANL has 70 years of experience in nuclear forensics and supports the community through a wide variety of efforts and leveraged capabilities: Expanding the understanding of nuclear forensics, providing training on nuclear forensics methods, and developing bilateral relationships to expand our understanding of nuclear forensic science. LANL remains highly supportive of several key organizations tasked with carrying forth the Nuclear Security Summit messages: IAEA, GICNT, and INTERPOL. Analytical chemistry measurements on plutonium and uranium matrices are critical to numerous programs including safeguards accountancy verification measurements. Los Alamos National Laboratory operates capable actinide analytical chemistry and material science laboratories suitable for nuclear material and environmental forensic characterization. Los Alamos National Laboratory uses numerous means to validate and independently verify that measurement data quality objectives are met. Numerous LANL nuclear facilities support the nuclear material handling, preparation, and analysis capabilities necessary to evaluate samples containing nearly any mass of an actinide (attogram to kilogram levels).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear forensic analysis of a non-traditional actinide sample

Nuclear forensic publications, performance tests, and research and development efforts typically target the bulk global inventory of intentionally safeguarded materials, such as plutonium (Pu) and uranium (U). Other materials, such as neptunium (Np), pose a nuclear security risk as well. Trafficking leading to recovery of an interdicted Np sample is a realistic concern especially for materials originating in countries that reprocesses fuel. Using complementary forensic methods, potential signatures for an unknown Np oxide sample were investigated. Measurement results were assessed against published Np processes to present hypotheses as to the original intended use, method of production, and origin for this Np oxide.

36 MATERIALS SCIENCE↗

Nuclear forensics of a non-traditional sample: Neptunium

Recent nuclear forensics cases have focused primarily on plutonium (Pu) and uranium (U) materials. By definition however, nuclear forensics can apply to any diverted nuclear material. This includes neptunium (Np), an internationally safeguarded material like Pu and U, that could offer a nuclear security concern if significant quantities were found outside of regulatory control. This case study couples scanning electron microscopy (SEM) with quantitative analysis using newly developed specialized software, to evaluate a non-traditional nuclear forensic sample of Np. Here, the results of the morphological analyses were compared with another Np sample of known pedigree, as well as other traditional actinide materials in order to determine potential processing and point-of-origin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗