Engineering topics
Tan, Hui
Publications and source records attributed to Tan, Hui.
Value of {sup 18}F-FDG PET/CT in the diagnosis of portal vein tumor thrombus in patients with hepatocellular carcinoma
Objective: The aim of this study was to evaluate the usefulness of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) for the diagnosis of a portal vein tumor thrombus (PVTT) in patients with hepatocellular carcinoma (HCC). Methods: One hundred fifty-four patients with histologically proven HCC underwent {sup 18}F-FDG PET/CT imaging. The maximum standardized uptake value (SUVmax) was calculated, and the change in SUVmax (retention index, RI) was defined as the ratio of the increase in SUVmax between early and delayed scans to the SUVmax in the early scan. The circular region of interest was placed on the transaxial images according to the corresponding CT images. The final diagnoses of a PVTT were confirmed by histopathology. Results: Of the patients examined, 101 (65.6%) had no confirmed instances of a PVTT, whereas 53 (34.4%) had a confirmed PVTT. The sensitivity of {sup 18}F-FDG PET/CT imaging was 62.3%, the specificity was 97.0%, the accuracy was 85.1%, the positive predictive value was 91.7%, and the negative predictive value was 83.1%. The SUVmax of the PVTT was 4.32 ± 1.96 and the SUVmax of the HCC lesions for these patients was 5.38 ± 2.79, but these differences were insignificant (t = 1.78, p = 0.08). For dual-time-point imaging, the SUV1 of the PVTT lesions was 3.75 ± 1.48, and SUV2 was 3.63 ± 1.41, but these differences were insignificant (t = 0.82, p = 0.42). The SUV1 of the HCC lesions was 4.47 ± 2.03, and the SUV2 was 4.90 ± 2.07, which were both also insignificant (t = − 1.81, p = 0.09). The RI of the PVTT lesions was − 2.05 ± 19.96%, and the RI of the HCC lesions was 11.87 ± 26.20%, with no significant differences between them (t = 1.58, p = 0.13). Conclusions: {sup 18}F-FDG PET/CT may potentially improve the accurate diagnoses of a PVTT in patients with HCC.
Relationship between KRAS mutations and dual time point {sup 18}F-FDG PET/CT imaging in colorectal liver metastases
Purpose: To investigate the association between metabolic parameters of dual time point {sup 18}F-FDG PET/CT imaging and Kirsten rat sarcoma (KRAS) mutation status in colorectal liver metastases (CRLM). Methods: Forty-nine colorectal cancer patients with 87 liver metastatic lesions were included in this retrospective study. KRAS gene mutation tests were also performed for all the patients. The maximum standardized uptake value (SUV{sub max}) was measured for each hepatic metastatic lesion on both early and delayed scans, and the change of SUV{sub max} (ΔSUV{sub max}) and retention index (RI) were calculated. Uni-variate and multi-variate analyses were employed to determine the relationship between any PET/CT parameters and KRAS mutation status. Results: Thirty-seven (42.5%) liver metastatic lesions harboring KRAS mutations were identified. The SUV{sub max} of CRLM with KRAS mutation both on early and delayed scans was significantly higher than those with wild-type KRAS (10.7 ± 6.0 vs. 7.8 ± 3.3, P = 0.002; 15.5 ± 10.1 vs. 10.0 ± 4.2, P < 0.001, respectively). Compared with wild-type KRAS CRLM, ΔSUV{sub max} and RI (%) of CRLM with KRAS mutation were also significantly higher than those with wild-type KRAS (4.8 ± 4.7 vs. 2.2 ± 2.0, P < 0.001; 45.3 ± 28.2 vs. 29.6 ± 24.7, P = 0.003, respectively). Multi-variate analyses showed that the SUV{sub max} on both early and delayed scans, ΔSUV{sub max}, and RI (%) were the 4 independent factors to predict CRLM patients harboring KRAS mutations. Conclusion: The SUV{sub max} on both early and delayed scans, ΔSUV{sub max}, and RI (%) may be the 4 independent factors to predict CRLM patients harboring KRAS mutations.
High Density Low Cost Readout Electronics for Large Scale Radiation Detectors
Explore the source record for details and available documents.
Omentin inhibits TNF-{alpha}-induced expression of adhesion molecules in endothelial cells via ERK/NF-{kappa}B pathway
Highlights: Black-Right-Pointing-Pointer Omentin inhibited TNF-{alpha}-induced adhesion of THP-1 cells to HUVECs. Black-Right-Pointing-Pointer Omentin reduces expression of ICAM-1 and VCAM-1 induced by TNF-{alpha} in HUVECs. Black-Right-Pointing-Pointer Omentin inhibits TNF-{alpha}-induced ERK and NF-{kappa}B activation in HUVECs. Black-Right-Pointing-Pointer Omentin supreeses TNF-{alpha}-induced expression of ICAM-1 and VCAM-1 via ERK/NF-{kappa}B pathway. -- Abstract: In the present study, we investigated whether omentin affected the expression of intracellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1) in tumor necrosis factor-{alpha} (TNF-{alpha}) induced human umbilical vein endothelial cells (HUVECs). Our data showed that omentin decreased TNF-{alpha}-induced expression of ICAM-1 and VCAM-1 in HUVECs. In addition, omentin inhibited TNF-{alpha}-induced adhesion of THP-1 cells to HUVECs. Further, we found that omentin inhibited TNF-{alpha}-activated signal pathway of nuclear factor-{kappa}B (NF-{kappa}B) by preventing NF-{kappa}B inhibitory protein (I{kappa}B{alpha}) degradation and NF-{kappa}B/DNA binding activity. Omentin pretreatment significantly inhibited TNF-{alpha}-induced ERK activity and ERK phosphorylation in HUVECs. Pretreatment with PD98059 suppressed TNF-{alpha}-induced NF-{kappa}B activity. Omentin, NF-kB inhibitor (BAY11-7082) and ERK inhibitor (PD98059) reduced the up-regulation of ICAM-1 and VCAM-1 induced by TNF-{alpha}. These results suggest that omentin may inhibit TNF-{alpha}-induced expression of adhesion molecules in endothelial cells via blocking ERK/NF-{kappa}B pathway.
Development of a Real-Time Pulse Processing Algorithm for TES-Based X-Ray Microcalorimeters
We report here a real-time pulse processing algorithm for superconducting transition-edge sensor (TES) based x-ray microcalorimeters. TES-based. microca1orimeters offer ultra-high energy resolutions, but the small volume of each pixel requires that large arrays of identical microcalorimeter pixe1s be built to achieve sufficient detection efficiency. That in turn requires as much pulse processing as possible must be performed at the front end of readout electronics to avoid transferring large amounts of data to a host computer for post-processing. Therefore, a real-time pulse processing algorithm that not only can be implemented in the readout electronics but also achieve satisfactory energy resolutions is desired. We have developed an algorithm that can be easily implemented. in hardware. We then tested the algorithm offline using several data sets acquired with an 8 x 8 Goddard TES x-ray calorimeter array and 2x16 NIST time-division SQUID multiplexer. We obtained an average energy resolution of close to 3.0 eV at 6 keV for the multiplexed pixels while preserving over 99% of the events in the data sets.
High rate pulse processing algorithms for microcalorimeters
It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.