Engineering topics
Tajima, T
Publications and source records attributed to Tajima, T.
Critical Magnetic Field Determination of Superconducting Materials
Superconducting RF technology is becoming more and more important. With some recent cavity test results showing close to or even higher than the critical magnetic field of 170-180 mT that had been considered a limit, it is very important to develop a way to correctly measure the critical magnetic field (H{sup RF}{sub c}) of superconductors in the RF regime. Using a 11.4 GHz, 50-MW, <1 {mu}s, pulsed power source and a TE013-like mode copper cavity, we have been measuring critical magnetic fields of superconductors for accelerator cavity applications. This device can eliminate both thermal and field emission effects due to a short pulse and no electric field at the sample surface. A model of the system is presented in this paper along with a discussion of preliminary experimental data.
Monoenergetic Ion Beam Generation by Driving Ion Solitary Waves with Circularly Polarized Laser Light
Experimental data from the Trident Laser facility is presented showing quasimonoenergetic carbon ions from nm-scaled foil targets with an energy spread of as low as {+-}15% at 35 MeV. These results and high-resolution kinetic simulations show laser acceleration of quasimonoenergetic ion beams by the generation of ion solitons with circularly polarized laser pulses (500 fs, {lambda}=1054 nm). The conversion efficiency into monoenergetic ions is increased by an order of magnitude compared with previous experimental results, representing an important step towards applications such as ion fast ignition.
High energy density and extreme field physics in the transparent-overdense regime
Conclusions of this report are: (1) high harmonics generated on solid surfaces are a very versatile source of intense coherent XUV radiation; (2) high harmonics can be used to probe and monitor the interaction of intense femtosecond laser pulses with nm-scale foil targets; (3) direct measurement of target density during relativistic interaction; (4) high harmonics generated with PW-scale short-pulse lasers could serve as unique backlighting sources for a wide range experiments; and (5) Trident can be a test bed to develop such experiments and the required instrumentation.
Autofocused, enhanced proton acceleration from a nanometer-scale bulged foil
We report an autofocused, enhanced proton acceleration by the interaction of an intense laser pulse with a bulged target. These results are obtained from two-dimensional particle-in-cell simulations using a real Gaussian laser pulse, normally incident on a bulged/planar, 60 nm thick foil (C:H=1:1). When the laser pulse hits the precurved target, energetic protons are converged on the axis automatically. For the bulged foil, due to oblique incidence at the wing region, the efficient vacuum heating at larger incidence angles will result in more energetic hot electrons than from the flat foil. The enhancement of hot electron temperature and density will result in a larger longitudinal field, which contributes to an enhancement of proton energy. The maximum proton energy of 124 MeV is attained from a bulged target irradiated by a linear polarized laser pulse at an intensity of 1.3x10{sup 20} W/cm{sup 2}, which is two times higher than from the planar target (61 MeV).
Intense High-Contrast Femtosecond K-Shell X-Ray Source from Laser-Driven Ar Clusters
Bright Ar quasimonochromatic K-shell x ray with very little background has been generated using an Ar clustering gas jet target irradiated with a 30 fs ultrahigh-contrast laser, with a measured flux of 2.2x10{sup 11} photons/J into 4{pi}. This intense x-ray source critically depends on the laser contrast and intensity. The optimization of source output with interaction length is addressed. Simulations point to a nonlinear resonant mechanism of electron heating during the early stage of laser interaction, resulting in enhanced x-ray emission. The x-ray pulse duration is expected to be only 10 fs, opening the possibility for single-shot ultrafast keV x-ray imaging applications.
Radiation-Pressure Acceleration of Ion Beams Driven by Circularly Polarized Laser Pulses
We present experimental studies on ion acceleration from ultrathin diamondlike carbon foils irradiated by ultrahigh contrast laser pulses of energy 0.7 J focused to peak intensities of 5x10{sup 19} W/cm{sup 2}. A reduction in electron heating is observed when the laser polarization is changed from linear to circular, leading to a pronounced peak in the fully ionized carbon spectrum at the optimum foil thickness of 5.3 nm. Two-dimensional particle-in-cell simulations reveal that those C{sup 6+} ions are for the first time dominantly accelerated in a phase-stable way by the laser radiation pressure.
Energy Increase in Multi-MeV Ion Acceleration in the Interaction of a Short Pulse Laser with a Cluster-Gas Target
An approach for accelerating ions, with the use of a cluster-gas target and an ultrashort pulse laser of 150-mJ energy and 40-fs duration, is presented. Ions with energy 10-20 MeV per nucleon having a small divergence (full angle) of 3.4 deg. are generated in the forward direction, corresponding to approximately tenfold increase in the ion energies compared to previous experiments using solid targets. It is inferred from a particle-in-cell simulation that the high energy ions are generated at the rear side of the target due to the formation of a strong dipole vortex structure in subcritical density plasmas.
Submicron ionography of nanostructures using a femtosecond-laser-driven-cluster-based source
An intense isotropic source of multicharged carbon and oxygen ions with energy above 300 keV and particle number >10{sup 8} per shot was obtained by femtosecond Ti:Sa laser irradiation of submicron clusters. The source was employed for high-contrast contact ionography images with 600 nm spatial resolution. A variation in object thickness of 100 nm was well resolved for both Zr and polymer foils.
Femtosecond-Laser-Driven Cluster-Based Plasma Source for High-Resolution Ionography
The intense isotropic source of multicharged ions, with energy above 300 keV, was produced by femtosecond Ti:Sa laser pulses irradiation (intensity of approx4x10{sup 17} W/cm{sup 2}) of the He and CO{sub 2} gases mixture expanded in supersonic jet. High contrast ionography images have been obtained for 2000 dpi metal mesh, 1 mum polypropylene and 100 nm Zr foils, as well as for different biological objects. Images were recorded on 1 mm thick CR-39 ion detector placed in contact with back surface of the imaged samples, at the distances 140-160 mm from the plasma source. The obtained spatial resolution of the image was approx600 nm. A 100 nm object thickness difference was resolved very well for both Zr and polymer foils. The multicharged ion energy for Carbon and Oxygen ions passing through the 1 mum polypropylene foil is estimated to give the energy of more than 300 keV. An almost equal number of ions were measured with total number of about 10{sup 8} per shot at a different direction from plasma source. Easy production of different sub-MeV ions in wide space angle, recognizes femtosecond-laser-driven-cluster-based plasma as a well-suited bright source for novel type of submicron ionography to image different media, including nanofoils, membranes, and other low-contrast objects.
Contact and Phase-Contrast Imaging of Nanostructures by Femtosecond-Laser-Driven-Cluster-Based Debris-Free Soft X-Ray Source
The high-intensive source of soft X-ray emission was developed by femtosecond laser pulses irradiation of submicron size CO{sub 2} clusters, produced in custom designed super-sonic nozzle while mixing the 10% CO{sub 2}+90% He expanding gases. The LiF crystal soft X-ray detectors have been used for obtaining absorption images of ultrathin (nanoscale) foils and biological structures illuminated by the developed source. It was demonstrated that even if the foil is essentially transparent for the soft X-ray radiation (like 100 nm thick Zr foil), the image contrast could be significantly increased due to the influence of propagation-based phase-contrast effect, by placing the detector at the proper distance from the sample.
SRF Cavity High-Gradient Study at 805 MHz for Proton and Other Applications
805 MHz elliptical SRF cavities have been used for SNS as the first application for protons. At LANL, an R&D started to explore a capability of getting high-gradient cavities (40-50 MV/m) at this frequency for the future applications such as proton and muon based interrogation testing facility added to the LANSCE accelerator and a power upgrade of the LANSCE accelerator for the fission and fusion material test station. Optimized cell designs for “standard”, “low-loss” and “re-entrant” shapes, cavity test results for “standard” single-cell cavities with temperature mapping as well as surface inspection results will be presented.
Opportunities for TeV Laser Acceleration
A set of ballpark parameters for laser, plasma, and accelerator technologies that define for electron energies reaching as high as TeV are identified. These ballpark parameters are carved out from the fundamental scaling laws that govern laser acceleration, theoretically suggested and experimentally explored over a wide range in the recent years. In the density regime on the order of 10{sup 16} cm{sup -3}, the appropriate laser technology, we find, matches well with that of a highly efficient high fluence LD driven Yb ceramic laser. Further, the collective acceleration technique applies to compactify the beam stoppage stage by adopting the beam-plasma wave deceleration, which contributes to significantly enhance the stopping power and energy recovery capability of the beam. Thus we find the confluence of the needed laser acceleration parameters dictated by these scaling laws and the emerging laser technology. This may herald a new technology in the ultrahigh energy frontier.
Relativistic Tennis Using Flying Mirror
Upon reflection from a relativistic mirror, the electromagnetic pulse frequency is upshifted and the duration is shortened by the factor proportional to the relativistic gamma-factor squared due to the double Doppler effect. We present the results of the proof-of-principle experiment for frequency upshifting of the laser pulse reflected from the relativistic 'flying mirror', which is a wake wave near the breaking threshold created by a strong driver pulse propagating in underdense plasma. Experimentally, the wake wave is created by a 2 TW, 76 fs Ti:S laser pulse from the JLITE-X laser system in helium plasma with the electron density of {approx_equal}4-6x10{sup 19} cm{sup -3}. The reflected signal is observed with a grazing-incidence spectrograph in 24 shots. The wavelength of the reflected radiation ranges from 7 to 14 nm, the corresponding frequency upshifting factors are {approx}55-115, and the gamma-factors are y = 4-6. The reflected signal contains at least 3x10{sup 7} photons/sr. This effect can be used to generate coherent high-frequency ultrashort pulses that inherit temporal shape and polarization from the original (low-frequency) ones. Apart from this, the reflected radiation contains important information about the wake wave itself, e.g. location, size, phase velocity, etc.
Notes on Laser Acceleration
This note intends to motivate our effort toward the advent of new methods of particle acceleration, utilizing the fast rising laser technology. By illustrating the underlying principles in an intuitive manner and thus less jargon-clad fashion, we seek a direction in which we shall be able to properly control and harness the promise of laser acceleration. First we review the idea behind the laser wakefield. We then go on to examine ion acceleration by laser. We examine the sheath acceleration in particular and look for the future direction that allows orderly acceleration of ions in high energies.
Sub-MeV tunably polarized X-ray production with laser Thomson backscattering
Reported in this article is the generation of unique polarized x-rays in the sub-MeV region by means of the Thomson backscattering of the Nd:YAG laser photon with a wavelength of 1064 nm on the 150 MeV electron from the microtron accelerator. The maximum energy of the x-ray photons is estimated to be about 400 keV. The total energy of the backscattered x-ray pulse is measured with an imaging plate and a LYSO scintillator. The angular divergence of the x-rays is also measured by using the imaging plate. We confirm that the x-ray beam is polarized according to the laser polarization direction with the Compton scattering method. In addition, we demonstrate the imaging of the object shielded by lead with the generated x-rays.
Soft x-ray source for nanostructure imaging using femtosecond-laser-irradiated clusters
The intense soft x-ray light source using the supersonic expansion of the mixed gas of He and CO{sub 2}, when irradiated by a femtosecond Ti:sapphire laser pulse, is observed to enhance the radiation of soft x-rays from the CO{sub 2} clusters. Using this soft x-ray emissions, nanostructure images of 100-nm-thick Mo foils in a wide field of view (mm{sup 2} scale) with high spatial resolution (800 nm) are obtained with high dynamic range LiF crystal detectors. The local inhomogeneities of soft x-ray absorption by the nanometer-thick foils is measured with an accuracy of less than {+-}3%.