Engineering Papers⌕ Search

Engineering topics

Syed, A. A.

Publications and source records attributed to Syed, A. A..

Acoustic Treatment Design Scaling Methods: Analytical and Experimental Data Correlation - Volume 5

The primary purpose of the study presented in this volume is to present the results and data analysis of in-duct transmission loss measurements. Transmission loss testing was performed on full-scale, 1/2-scale, and 115-scale treatment panel samples. The objective of the study was to compare predicted and measured transmission loss for full-scale and subscale panels in an attempt to evaluate the variations in suppression between full- and subscale panels which were ostensibly of equivalent design. Generally, the results indicated an unsatisfactory agreement between measurement and prediction, even for full-scale. This was attributable to difficulties encountered in obtaining sufficiently accurate test results, even with extraordinary care in calibrating the instrumentation and performing the test. Test difficulties precluded the ability to make measurements at frequencies high enough to be representative of subscale liners. It is concluded that transmission loss measurements without ducts and data acquisition facilities specifically designed to operate with the precision and complexity required for high subscale frequency ranges are inadequate for evaluation of subscale treatment effects.

Chien, W. E.↗

Acoustic Treatment Design Scaling Methods: Test Plans, Hardware, Results, and Evaluation - Volume 3

The ability to design, build, and test miniaturized acoustic treatment panels on scale-model fan rigs representative of the full-scale engine provides not only a cost-savings, but an opportunity to optimize the treatment by allowing tests of different designs. To be able to use scale model treatment as a full-scale design tool, it is necessary that the designer be able to reliably translate the scale model design and performance to an equivalent full-scale design. The primary objective of the study presented in this volume of the final report was to conduct laboratory tests to evaluate liner acoustic properties and validate advanced treatment impedance models. These laboratory tests include DC flow resistance measurements, normal incidence impedance measurements, DC flow and impedance measurements in the presence of grazing flow, and in-duct liner attenuation as well as modal measurements. Test panels were fabricated at three different scale factors (i.e., full-scale, half-scale, and one-fifth scale) to support laboratory acoustic testing. The panel configurations include single-degree-of-freedom (SDOF) perforated sandwich panels, SDOF linear (wire mesh) liners, and double-degree-of-freedom (DDOF) linear acoustic panels.

Yu, J.↗

Turbofan aft duct suppressor study. Contractor's data report of mode probe signal data

Acoustic modal distributions were measured in a fan test model having an annular exhaust duct for comparison with theoretically predicted acoustic suppression values. This report contains the amplitude and phase data of the acoustic signals sensed by the transducers of the two mode probes employed in the measurement. Each mode probe consisted of an array of 12 transducers sensing the acoustic field at three axial positions and four radial positions.

Fiske, G. H.↗

Turbofan aft duct suppressor study

Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.

Syed, A. A.↗

Measurement of acoustic modes and wall impedance in a turbofan exhaust duct

Acoustic measurements made with in-duct modal probes show how individual acoustic modes, as generated by fan/stator interaction, interact with a well-characterized liner. This measured attenuation provides a critical test for predicted attenuation as developed from the theoretical analysis of sound propagation in annular ducts with treatment and sheared flow. The primary investigations took place in the exhaust duct of a model fan mounted in an anechoic chamber. The results presented include induct attenuation, sound power attenuation as measured in the far field, and in-situ acoustic impedance measurements of the treated wall sections. Good theory/experiment agreement was found; the differences of treatment suppression between theory and measured values differed at most by 2.7 dB.

Fiske, G. H.↗

Sound propagation in segmented exhaust ducts - Theoretical predictions and comparison with measurements

Suppressions due to acoustic treatment in the annular exhaust duct of a model fan have been theoretically predicted and compared with measurements. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Measured values of the mode distribution of the fan noise source (fan-stator interaction source only) and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions (under the assumption of uniform flow in the duct) compared well with the measured in-duct suppression for all test conditions. The measurements were made in an anechoic chamber and the interaction modes generated in the fan spanned a cut-off ratio range from nearly one to seven.

Joshi, M. C.↗