Engineering Papers⌕ Search

Engineering topics

Sun, Eric

Publications and source records attributed to Sun, Eric.

Modular adjuvant-free pan-HLA-DR-immunotargeting subunit vaccine against SARS-CoV-2 elicits broad sarbecovirus-neutralizing antibody responses

Subunit vaccines typically require co-administration with an adjuvant to elicit protective immunity, adding development hurdles that can impede rapid pandemic responses. To circumvent the need for adjuvant in a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) subunit vaccine, we engineer a thermostable immunotargeting vaccine (ITV) that leverages the pan-HLA-DR monoclonal antibody 44H10 to deliver the viral spike protein receptor-binding domain (RBD) to antigen-presenting cells. X-ray crystallography shows that 44H10 binds to a conserved epitope on HLA-DR, providing the basis for its broad HLA-DR reactivity. Adjuvant-free ITV immunization in rabbits and ferrets induces robust anti-RBD antibody responses that neutralize SARS-CoV-2 variants of concern and protect recipients from SARS-CoV-2 challenge. We demonstrate that the modular nature of the ITV scaffold with respect to helper T cell epitopes and diverse RBD antigens facilitates broad sarbecovirus neutralization. Our findings support anti-HLA-DR immunotargeting as an effective means to induce strong antibody responses to subunit antigens without requiring an adjuvant.

60 APPLIED LIFE SCIENCES↗

Comparison of Multi-Scale Nonlinear and Conventional Linear Methods for Stress Analysis of Nb 3 Sn Superconducting Magnets

Here this is an extension of the work on a multi-scale nonlinear procedure that demonstrated how to conduct nonlinear stress analysis of Nb 3 Sn superconducting accelerator magnets. The nonlinear procedure uses measured stress-strain curves of annealed copper, Nb 3 Sn strands and coil samples as inputs, which reduces the number of assumptions made for material properties—key uncertainties of any engineering analysis. The results from nonlinear analysis, semi-nonlinear analysis, and linear analysis of the same QFFB2 Nb 3 Sn quadrupole magnet under the same temperature and loads, were compared and discussed. The comparison illustrates that nonlinear stress analysis is significantly more accurate than other methods. As the superconducting coil block is a complex, composite material, it would be inadequate to assume the whole coil block to be linear, either isotropic or orthotropic. It is imperative to conduct nonlinear analysis by simulating the superconducting coil to the level of detail of the individual cables and individual strands. The nonlinear stress analysis procedure can be used to simulate not only Nb 3 Sn magnets, but also NbTi and HTS magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench-Back Management for Fast Decaying Currents in SHMS Superconducting Magnets at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) of Hall C, part of the 12-GeV upgrade at Jefferson Lab, was successfully commissioned in 2017. Early operation demonstrated that fast current dumps decays of the SHMS Q2/Q3 and dipole superconducting magnets triggered quenches, causing some level of operational difficulty. Tests and detailed assessments suggest that nonquench induced fast current decay could result in substantial ac loss in the conductor and subsequently trigger a quench-back effect. The OPERA/ELECTRA software package was used to calculate the amount of heat deposited in the copper stabilizer from a fast current decay. The resistances of external energy dump resistors were lowered to slow the fast dumping of the magnet's current to reduce or eliminate the quench-back effect. A worst-case adiabatic quench scenario was analyzed, assuming no external dump resistor and no liquid helium surrounding the coil, to ensure the safety of the magnets. The stress levels in the coil imposed by winding, collaring preload, Lorentz force, and temperature gradient during a quench were also examined. The Tsai-Wu material failure criterion was used to determine the acceptable combined stress level. Linear orthotropic analysis of the coil indicates that the magnets can be operated safely with appropriately sized dump resistors. Fast dump tests with the modified dump resistors have been planned to verify the performance and suitability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Safe assembly and installation of a flywheel

A flywheel device includes structures allowing the flywheel system to be assembled offsite, transported safely, and installed with relatively few steps. The flywheel includes a rotor and a housing enclosing the rotor, where the housing includes a bottom plate, a top plate and side walls. The bottom plate and the top plate each includes a hole aligned with the center axis of the rotor. The flywheel also includes multiple bearing housings substantially covering the holes of the bottom plate and the top plate that are aligned to the center axis of the rotor. The flywheel also includes posts that physically contact the primary rotational mass of the rotor to prevent motion of the rotor during transport of the flywheel system. Some or all of these posts may be repositioned or removed during installation so that the rotor can spin freely.

Sun, Eric↗

Stub shaft for connection with a flywheel rotor

An energy storage system including a solid steel flywheel rotor, journals, and separate stub shafts for connecting to the journals has improved material properties offers improved energy storage at reduced cost.

42 ENGINEERING↗

Flywheel rotor

A solid steel flywheel rotor having improved material properties offers improved energy storage at reduced cost. A process for manufacturing the rotor is also provided.

42 ENGINEERING↗

Final Assembly and Factory Testing of the Jefferson Lab SHMS Spectrometer Quadrupole and Dipole Superconducting Magnets

Jefferson Lab is constructing an 11 Gev/c electron spectrometer called the Super High Momentum Spectrometer (SHMS) as part of the 12 GeV JLAB upgrade for experimental Hall C. Three of the five superconducting(SC) SHMS magnets are under construction at SigmaPhi in Vannes France as a result of an international competition for design and fabrication. The three magnets Q2 and Q3 60 cm bore quadrupoles and the 60 cm warm bore dipole are complete or near complete and have many design features in common. All three magnets share a common superconductor, collaring system, cryostat design, cold to warm support, cryogenic interface, burnout resistant current leads, DC power supply, quench protection, instrumentation and controls. The three magnets are collared, installed in cryostats and welded up and in various stages of final testing. The Q2 quadrupole is due to ship from France to America in August arriving during this ASC conference and has passed all final hipot, leak and pressure tests. The dipole is in leak and pressure testing as of July 2016 while the Q3 quadrupole requires some outer vacuum vessel assembly. Delivery of the Q3 and Dipole magnets will follow the Q2 at about 1 month intervals. Lastly, factory testing have included hipot and electrical tests, magnetic tests at low field, mechanical alignments to center the coils, leak tests and ASME Code required pressure tests. Upon installation in Hall C at JLAB cold testing will commence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning of horizontal-bend superconducting magnet for Jefferson Lab's 11-GeV super high momentum spectrometer

Commissioning characteristics of the Superconducting High Momentum Spectrometer (SHMS) Horizontal Bend (HB) magnet was presented. Pre-commissioning peer review of the magnet uncovered issues with eddy currents in the thermal shield, resulting in additional testing and modeling of the magnet. A three-stage test plan was discussed. A solution of using a small dump resistor and a warm thermal shield was presented. Analyses illustrated that it was safe to run the magnet to full test current. As a result, the HB magnet was successfully cooled to 4 K and reached its maximum test current of 4000 A.

47 OTHER INSTRUMENTATION↗

JLAB's Super High Momentum Spectrometer's Superconducting Q1 Magnet

Abstract- The commissioning and test results of a super ferric, superconducting, quadrupole magnet, constructed by Scientific Magnetics Inc. for Thomas Jefferson National Accelerator Facility (TJNAF also known as JLAB) will be presented. The quadrupole magnet, named Q1, is the first focusing element in the Super High Momentum Spectrometer (SHMS). The SHMS, located within JLAB's experimental Hall C, consists of all superconducting magnets in a dQQQD configuration and is part of the JLAB's 12 Gev upgrade. Here "d" refers to the small horizontal bend dipole, "Q" stands for focusing quadrupole magnets and "D" is the vertical bending, momentum-selecting dipole magnet. Characterization of the magnet's cryogenic heat loads and magnetic field quality will be presented along with descriptions of the magnet's control system, power supply, and quench detection system.

Superconductor Magnets, Detector Magnets, Cold Iro↗