Engineering Papers⌕ Search

Engineering topics

Sullivan, T. J.

Publications and source records attributed to Sullivan, T. J..

Aerodynamic performance of a scale-model, counterrotating unducted fan

The aerodynamic performance of a scale model, counter-rotating unducted fan has been determined and the results are discussed. Experimental investigations were conducted using the scale model propulsor simulator and uniquely shaped fan blades. The blades, designed for a high disk loading at Mach 0.72 at 35,000 feet altitude maximum climb condition are aft-mounted on the simulator in a pusher configuration. Data are compared with analytical predictions at the design point and show good agreement.

Sullivan, T. J.↗

Simulating transitional flow and heat transfer over the flat plate and circular cylinder using a K-epsilon turbulence model

A boundary layer computer code, called TEXSTAN, has been used to simulate external, transitional, fluid flow and heat transfer over the flat plate and circular cylinder. Turbulence modeling was accomplished by using a low-Reynolds number K-epsilon turbulence model. The study was made for free-stream turbulence intensities less than 15 percent. The comparison of the flat plate heat transfer predictions to experimental data showed good agreement, for the location of transition as well as in the heat transfer coefficient. The typical discrepancy in predicting the heat transfer coefficient was less than 5 percent of the measured value.

Sullivan, T. J.↗

Evaluation of a Stirling engine heater bypass with the NASA Lewis nodal-analysis performance code

In support of the U.S. Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Research Center investigated whether bypassing the P-40 Stirling engine heater during regenerative cooling would improve engine performance. The Lewis nodal-analysis Stirling engine computer simulation was used for this investigation. Results for the heater-bypass concept showed no significant improvement in the indicated thermal efficiency for the P-40 Stirling engine operating at full-power and part-power conditions. Optimizing the heater tube length produced a small increase in the indicated thermal efficiency with the heater-bypass concept.

Sullivan, T. J.↗

The aerodynamic design and performance of the General Electric/NASA EEE fan

The aerodynamic design and test results of the fan and quarter-stage component for the GE/NASA Energy Efficient Engine (EEE) are presented. The fan is a high bypass ratio, single-stage design having 32 part-span shrouded rotor blades, coupled with a unique quarter-stage arrangement that provides additional core-stream pressure ratio and particle separation. The fan produces a bypass pressure ratio of 1.65 at the exit of the low aspect ratio vane/frame and a core-stream pressure ratio of 1.67 at the entrance to the core frame struts. The full-scale fan vehicle was instrumented, assembled and tested as a component in November 1981. Performance mapping was conducted over a range of speeds and bypass ratios using individually-controlled bypass and core-stream discharge valves. The fan bypass and core-stream test data showed excellent results, with the fan exceeding all performance goals at the important engine operating conditions.

Sullivan, T. J.↗

The DMSP/MFR total ozone and radiance data base

This report describes the entries in sufficient detail so that the data base might be useful to others. The characteristics of the MFR sensor are briefly discussed and a complete index to the data base tapes is given.

Ellis, J. S.↗

Energy efficient engine. Fan and quarter-stage component performance report

The fan configuration for the general Electric/NASA Energy Efficient Engine was selected following an extensive preliminary design study. The fan has an inlet radius ratio of 0.342 and a specific flowrate of 208.9 Kg/sec/sq. m (42.8 1bm/sec/sq. ft). The design corrected tip speed is 411.5 m/sec (1350 ft/sec) producing a bypass flow total-pressure ratio of 1.65 and a core flow total-pressure ratio of 1.6. The design bypass ratio is 6.8. The aerodynamic design point corresponds to the maximum climb power setting at Mach 0.8 and 10.67 Km (35,000 ft) altitude. The fully-instrumented fan component was tested in the Lynn Large Fan Test Facility in 1981. The overall performance results, reported herein, showed excellent fan performance with the fan meeting all of its component test goals of flow, efficiency and stall margin.

Cline, S. J.↗

Defense meteorological satellite measurements of total ozone

A multichannel filter radiometer (MFR) on Defense Meteorological Satellites (DMS) that measured total ozone on a global-scale from March 1977 - February 1980 is described. The total ozone data measured by the MFR were compared with total ozone data taken by surfaced-based Dobson spectrophotometers. When comparisons were made for five months, the Dobson spectrophotometer measured 2-5% more total ozone than the MFR. Comparisons between the Dobson spectrophotometer and the MFR showed a reduced RMS difference as the comparisons were made at closer proximity. A Northern Hemisphere total ozone distribution obtained from MFR data is presented.

Lovill, J. E.↗

Energy efficient engine: Fan test hardware detailed design report

A single stage fan and quarter stage booster were designed for the energy efficient engine. The fan has an inlet radius ratio of 0.342 and a specific flow rate of 208.9 Kg/S sq m (42.8 lbm/sec sq ft). The fan rotor has 32 medium aspect ratio (2.597) titanium blades with a partspan shroud at 55% blade height. The design corrected fan tip speed is 411.5 M/S (1350 ft/sec). The quarter stage island splits the total fan flow with approximately 22% of the flow being supercharged by the quarter stage rotor. The fan bypass ratio is 6.8. The core flow total pressure ratio is 1.67 and the fan bypass pressure ratio is 1.65. The design details of the fan and booster blading, and the fan frame and static structure for the fan configuration are presented.

Sullivan, T. J.↗

Design study and performance analysis of a high-speed multistage variable-geometry fan for a variable cycle engine

A design technology study was performed to identify a high speed, multistage, variable geometry fan configuration capable of achieving wide flow modulation with near optimum efficiency at the important operating condition. A parametric screening study of the front and rear block fans was conducted in which the influence of major fan design features on weight and efficiency was determined. Key design parameters were varied systematically to determine the fan configuration most suited for a double bypass, variable cycle engine. Two and three stage fans were considered for the front block. A single stage, core driven fan was studied for the rear block. Variable geometry concepts were evaluated to provide near optimum off design performance. A detailed aerodynamic design and a preliminary mechanical design were carried out for the selected fan configuration. Performance predictions were made for the front and rear block fans.

Sullivan, T. J.↗

Single-stage, low-noise, advanced technology fan. Volume 4: Fan aerodynamics. Section 1: Results and analysis

Test results at design speed show fan total pressure ratio, weight flow, and adiabatic efficiency to be 2.2, 2.9, and 1.8% lower than design goal values. The hybrid acoustic inlet (which utilizes a high throat Mach number and acoustic wall treatment for noise suppression) demonstrated total pressure recoveries of 98.9% and 98.2% at takeoff and approach. Exhaust duct pressure losses differed between the hardwall duct and treated duct with splitter by about 0.6% to 2.0% in terms of fan exit average total pressure (depending on operating condition). When the measured results were used to estimate pressure losses, a cruise sfc penalty of 0.68%, due to the acoustically treated duct, was projected.

Sullivan, T. J.↗

Single stage, low noise, advanced technology fan. Volume 1: Aerodynamic design

The aerodynamic design for a half-scale fan vehicle, which would have application on an advanced transport aircraft, is described. The single stage advanced technology fan was designed to a pressure ratio of 1.8 at a tip speed of 503 m/sec 11,650 ft/sec). The fan and booster components are designed in a scale model flow size convenient for testing with existing facility and vehicle hardware. The design corrected flow per unit annulus area at the fan face is 215 kg/sec sq m (44.0 lb m/sec sq ft) with a hub-tip ratio of 0.38 at the leading edge of the fan rotor. This results in an inlet corrected airflow of 117.9 kg/sec (259.9 lb m/sec) for the selected rotor tip diameter if 90.37 cm (35.58 in.). The variable geometry inlet is designed utilizing a combination of high throat Mach number and acoustic treatment in the inlet diffuser for noise suppression (hybrid inlet). A variable fan exhaust nozzle was assumed in conjunction with the variable inlet throat area to limit the required area change of the inlet throat at approach and hence limit the overall diffusion and inlet length. The fan exit duct design was primarily influenced by acoustic requirements, including length of suppressor wall treatment; length, thickness and position on a duct splitter for additional suppressor treatment; and duct surface Mach numbers.

Sullivan, T. J.↗