Engineering Papers⌕ Search

Engineering topics

Sullivan, Joseph

Publications and source records attributed to Sullivan, Joseph.

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Bit Error Rate Performance of a Free Space Optical Link Using Double Clad Fibers

Mobile and embedded applications are emerging in the growing field of free space optical links (FSOL). Some mobile applications for FSOL include spacecraft, aircraft, and automotive. These applications by nature require low size weight and power (SWaP) solutions. The main challenge with any FSOL system is the strict pointing requirements. Common solutions to pointing and alignment of FSOL include gimbals, fast steering mirrors, and adaptive optics. All of which provide viable solutions at the cost of increased SWaP. Previously, we presented the use of both large core fibers and double clad fibers (DCF) to interface FSOL transmit and receive optics with small form factor pluggable optical transceivers (SFP). Double clad fibers have been shown to enable a common optical path by transmitting through a single mode core and receiving through a large inner cladding. This enables a single set of symmetric transmit and receive optics, which decreases the SWaP. In addition, using DCF increases the received power stability of the link relative to a multi-mode fiber (MMF) transmitting. To determine the viability of the system, bit error rate performance needs to be investigated. The results of this paper show that at a bit rate of 10 Gbps, double clad fibers offer similar bit error rate performance to single mode fibers when transmitting and multi-mode fibers when receiving enabling a symmetric duplex FSOL reducing SWaP.

Small Form-Factor Pluggable Optical Transceiver↗

Bit Error Rate Performance of a Free Space Optical Link Using Double Clad Fibers

Mobile and embedded applications are emerging in the growing field of free space optical links (FSOL). Some mobile applications for FSOL include spacecraft, aircraft, and automotive. These applications by nature require low size weight and power (SWaP) solutions. The main challenge with any FSOL system is the strict pointing requirements. Common solutions to pointing and alignment of FSOL include gimbals, fast steering mirrors, and adaptive optics. All of which provide viable solutions at the cost of increased SWaP. Previously, we presented the use of both large core fibers and double clad fibers (DCF) to interface FSOL transmit and receive optics with small form factor pluggable optical transceivers (SFP). Double clad fibers have been shown to enable a common optical path by transmitting through a single mode core and receiving through a large inner cladding. This enables a single set of symmetric transmit and receive optics, which decreases the SWaP. In addition, using DCF increases the received power stability of the link relative to a multi-mode fiber (MMF) transmitting. To determine the viability of the system, bit error rate performance needs to be investigated. The results of this paper show that at a bit rate of 10 Gbps, double clad fibers offer similar bit error rate performance to single mode fibers when transmitting and multi-mode fibers when receiving enabling a symmetric duplex FSOL reducing SWaP.

Double Clad Fiber↗

Metrology for Trending Alignment of the James Webb Space Telescope Before and After Ambient Environmental Testing

NASAs James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element which contains four science instruments (SIs). Prior to integration with the spacecraft, the JWST optical assembly is put through rigorous launch condition environmental testing. This work reports on the metrology operations conducted to determine any changes in subassembly alignment, including primary mirror segments with respect to each other, the secondary mirror to its support structure, the tertiary mirror assembly to the backplane of the telescope and ultimately to the ISIM.

instrument development↗

Metrology for Trending Alignment of the James Webb Space Telescope Before and After Ambient Environmental Testing

NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element which contains four science instruments (SIs). Prior to integration with the spacecraft, theJWST optical assembly is put through rigorous launch condition environmental testing. This work reports on the metrology operations conducted to determine any changes in subassembly alignment, including primary mirror segments with respect to each other, the secondary mirror to its support structure, the tertiary mirror assembly to the backplane of the telescope and ultimately to the ISIM.

technology development↗

Cryogenic Optical Position Encoders for Mechanisms in the JWST Optical Telescope Element Simulator (OSIM)

The JWST Optical Telescope Element Simulator (OSIM) is a configurable, cryogenic, optical stimulus for high fidelity ground characterization and calibration of JWST's flight instruments. OSIM and its associated Beam Image Analyzer (BIA) contain several ultra-precise, cryogenic mechanisms that enable OSIM to project point sources into the instruments according to the same optical prescription as the flight telescope images stars - correct in focal surface position and chief ray angle. OSIM's and BIA's fifteen axes of mechanisms navigate according to redundant, cryogenic, absolute, optical encoders - 32 in all operating at or below 100 K. OSIM's encoder subsystem, the engineering challenges met in its development, and the encoders' sub-micron and sub-arcsecond performance are discussed.

Leviton, Douglas B.↗

Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies

The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) contains the observatory's four science instruments and their support subsystems. During alignment and test of the integrated ISIM at NASA's Goddard Space Flight Center (GSFC), the Optical'telescope element SIMulator (OSIM) will be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. These fixtures, the Master Alignment Target Fixture (MAW) and the ISIM Alignment Target Fixture (IATF), will provide continuous, six degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing. These fixtures will allow us to position the OSIM and maintain OSIM-ISIM alignment to better than 10 microns in translation and 250 micro-radians in rotation. We will provide a brief overview of the OSIM system and calibration and we will also discuss the relevance of these fixtures in the context of the overall ISIM alignment and verification plan.

Frey, Bradley J.↗

An Overview of Integration and Test of the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The SIs and Guider are mounted to a composite metering structure with outer dimensions of 2.1x2.2x1.9m. The SI and Guider units are integrated to the ISIM structure and optically tested at NASA/Goddard Space Flight Center as an instrument suite using a high-fidelity, cryogenic JWST telescope simulator that features a 1.5m diameter powered mirror. The SIs are integrated and aligned to the structure under ambient, clean room conditions. SI performance, including focus, pupil shear and wavefront error, is evaluated at the operating temperature. We present an overview of the ISIM integration within the context of Observatory-level construction. We describe the integration and verification plan for the ISIM element, including an overview of our incremental verification approach, ambient mechanical integration and test plans and optical alignment and cryogenic test plans. We describe key ground support equipment and facilities.

Drury, Michael↗

Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies

The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) is the scientific payload of the observatory and contai ns four science instruments. During alignment and test of the integrated ISIM (i.e. ISIM + science instruments) at NASA's Goddard Space Fli ght Center (GSFC), the Optical telescope element SIMulator (OSIM) wil l be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. The se fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, 6 degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing.

Frey, Bradley J.↗

BOREAS TE-10 Photosynthetic Response Data

The Boreal Ecosystem-Atmospheric Study (BOREAS) TE-10 (Terrestrial Ecology) team collected several data sets in support of its efforts to characterize and interpret information on the gas exchange, reflectance, transmittance, chlorophyll content, carbon content, hydrogen content, nitrogen content, and photosynthetic response of boreal vegetation. This data set contains measurements of quantitative parameters and leaf photosynthetic response to increases in light conducted in the SSA during the growing seasons of 1994 and 1996 using an oxygen electrode system. Leaf photosynthetic responses were not collected in 1996. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

BOREAS TE-10 Leaf Gas Exchange Data

The Boreal Ecosystem-Atmospheric Study (BOREAS) TE-10 (Terrestrial Ecology) team collected several data sets in support of its efforts to characterize and interpret information on the reflectance, transmittance, gas exchange, chlorophyll content, carbon content, hydrogen content, and nitrogen content of boreal vegetation. This data set contains measurements of assimilation, stomatal conductance, transpiration, internal CO2 concentration, and water use efficiency conducted in the Southern Study Area (SSA) during the growing seasons of 1994 and 1996 using a portable gas exchange system. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

BOREAS TE-10 Leaf Chemistry Data

The BOREAS TE- 10 team collected several data sets in support of its efforts to characterize and interpret information on the reflectance, transmittance, gas exchange, chlorophyll content, carbon content, hydrogen content, and nitrogen content of boreal vegetation. This data set describes the relationship between sample location, age, chlorophyll content, and C-H-N concentrations at several sites in the SSA conducted during the growing seasons of 1994 and 1996. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Center (DAAC).

Hall, Forrest G.↗