Engineering Papers⌕ Search

Engineering topics

Sukhanov, A.

Publications and source records attributed to Sukhanov, A..

At least 19 records

Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Couplers in the Fermilab Spoke Test Cryostat

As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.

43 PARTICLE ACCELERATORS↗

Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Coupler in the Fermilab Spoke Test Cryostat

As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.

Sukhanov, A.↗

PIP-II High Beta 650 Prototype Cryomodule Assembly Experience and Related Design Optimization

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

Ozelis, J.↗

Testing of the SSR2 SRF Cavity Tuner for PIP-II at 2 K

The PIP-II linac will include thirty-five 325 MHz Single Spoke Resonators Type 2 (SSR2) cavities. Each cavity will be equipped with a tuner for resonance control. The tuner consists of mechanical frame with a motor for coarse frequency tuning and a piezoelectric actuator for fine frequency tuning. The tuner was tested for the first time at Fermilab on an SSR2 cavity. This dressed cavity-tuner system was tested at the single spoke testing cryo-stat (STC) in Fermilab at 2 K. The tuner performance was evaluated and is presented. Lastly, cavity-tuner mechanical modes were measured via the piezos.

Contreras-Martinez, C.↗

Results of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and discuss the possible contribution of HOMs to heat loads and beam dynamics.

43 PARTICLE ACCELERATORS↗

HOM Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped super-conducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and dis-cuss the possible contribution of HOMs to heat loads and beam dynamics.

Lunin, A.↗

Impact of Solenoid Induced Residual Magnetic Fields on The Prototype SSR1 CM Performance

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, design optimizations for the production cryomodules as a result of this impact are highlighted.

43 PARTICLE ACCELERATORS↗

Impact of solenoid induced residual magnetic fields on the prototype SSR1 CM performance

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, design optimizations for the production cryomodules as a result of this impact are highlighted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Testing of PIP-II pre-production 650 MHz couplers in warm test stand and in cryomodule

650 MHz fundamental power couplers were developed for PIP-II project to deliver RF power for low-beta and high-beta elliptical cavities. Few prototypes were built and tested and after some modification we built 8 pre-production couplers (with few spares for vacuum side) for HB650 cryomodule. All couplers were successfully tested in pulse mode (up to 100kW) and in CW mode (up to 50kW) in test stand at full reflection at 8 phases. In baseline configuration with DC bias we do not see any multipactoring activity after short processing. We also tested power processing without bias for uncoated and TiN coated ceramic window. Results of these studies presented in this paper. One of the coupler was assembled on LB650 cavity and tested at cryogenic environment in STC cryostat at ~20kW power with full reflection at different reflection phase. We also demonstrated good result from power processing without bias for warm and cold cavity. Six couplers were assembled on HB650 cavities in pre-production cryomodule. Test results from cryomodule qualification is discussing in this paper.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of Hadron Beam Cooling Using Radio-Frequency Accelerated Electron Bunches

Cooling of beams of gold ions using electron bunches accelerated with radio-frequency systems was recently experimentally demonstrated in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. Such an approach is new and opens the possibility of using this technique at higher energies than possible with electrostatic acceleration of electron beams. The challenges of this approach include generation of electron beams suitable for cooling, delivery of electron bunches of the required quality to the cooling sections without degradation of beam angular divergence and energy spread, achieving the required small angles between electron and ion trajectories in the cooling sections, precise velocity matching between the two beams, high-current operation of the electron accelerator, as well as several physics effects related to bunched-beam cooling. Here we report on the first demonstration of cooling hadron beams using this new approach.

43 PARTICLE ACCELERATORS↗