Engineering PapersSearch

Engineering topics

Suarez, Vicente

Publications and source records attributed to Suarez, Vicente.

Utilizing Modal Testing for Monitoring the Structural Health of Wind Tunnel Facility Hardware

The 10- by 10-Foot Abe Silverstein Supersonic Wind Tunnel (10×10) is the largest and fastest wind tunnel facility at NASA’s Glenn Research Center(GRC) and is specifically designed to test supersonic propulsion components from inlets and nozzles to full-scale jet and rocket engines[1]. Recently, a critical part of the wind tunnel failed and required a redesign before reintegrating into the facility. The design requirements of this new component required that clearances between large metallic components exist, which have the potential for undesirable nonlinear dynamics to occur, in particular rattling. Rattling is feared to occur when the wind tunnel is being operated in certain flow regimes that induce cyclic aero loads on the new component near its natural frequencies. This paper describes the approach taken to better understand and resolve this vibration problem using modal testing. A modal test was developed and executed by GRC’s Structural Dynamics Lab to quantify the modal parameters of the structure, namely which specific excitation frequencies caused the structure to rattle. These results were shared with facility operators as frequency ranges that should be avoided to ensure maximum lifespan of the new structure. Additional means of structural health monitoring (SHM) as well as Vortex shedding are briefly discussed in this paper.

Pederson, Kenneth

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Base-Shake

Orion MPCV Service Module Avionics Ring Pallet Testing, Correlation, and Analysis

The NASA Orion Multi-Purpose Crew Vehicle (MPCV) is being designed to replace the Space Shuttle as the main manned spacecraft for the agency. Based on the predicted environments in the Service Module avionics ring, an isolation system was deemed necessary to protect the avionics packages carried by the spacecraft. Impact, sinusoidal, and random vibration testing were conducted on a prototype Orion Service Module avionics pallet in March 2010 at the NASA Glenn Research Center Structural Dynamics Laboratory (SDL). The pallet design utilized wire rope isolators to reduce the vibration levels seen by the avionics packages. The current pallet design utilizes the same wire rope isolators (M6-120-10) that were tested in March 2010. In an effort to save cost and schedule, the Finite Element Models of the prototype pallet tested in March 2010 were correlated. Frequency Response Function (FRF) comparisons, mode shape and frequency were all part of the correlation process. The non-linear behavior and the modeling the wire rope isolators proved to be the most difficult part of the correlation process. The correlated models of the wire rope isolators were taken from the prototype design and integrated into the current design for future frequency response analysis and component environment specification.

Staab, Lucas

CoNNeCT Antenna Positioning System Dynamic Simulator Modal Model Correlation

The National Aeronautics and Space Administration (NASA) developed an on-orbit, adaptable, Software Defined Radios (SDR)/Space Telecommunications Radio System (STRS)-based testbed facility to conduct a suite of experiments to advance technologies, reduce risk, and enable future mission capabilities on the International Space Station (ISS). The Communications, Navigation, and Networking reConfigurable Testbed (CoNNeCT) Project will provide NASA, industry, other Government agencies, and academic partners the opportunity to develop and field communications, navigation, and networking technologies in both the laboratory and space environment based on reconfigurable, software-defined radio platforms and the STRS Architecture. The CoNNeCT Payload Operations Nomenclature is "SCAN Testbed," and this nomenclature will be used in all ISS integration, safety, verification, and operations documentation. The SCAN Testbed (payload) is a Flight Releasable Attachment Mechanism (FRAM) based payload that will launch aboard the Japanese H-II Transfer Vehicle (HTV) Multipurpose Exposed Pallet (EP-MP) to the International Space Station (ISS), and will be transferred to the Express Logistics Carrier 3 (ELC3) via Extravehicular Robotics (EVR). The SCAN Testbed will operate on-orbit for a minimum of two years.

Jones, Tevor M.

Application of the Semi-Empirical Force-Limiting Approach for the CoNNeCT SCAN Testbed

The semi-empirical force-limited vibration method was developed and implemented for payload testing to limit the structural impedance mismatch (high force) that occurs during shaker vibration testing. The method has since been extended for use in analytical models. The Space Communications and Navigation Testbed (SCAN Testbed), known at NASA Glenn Research Center (GRC) as, the Communications, Navigation, and Networking re-Configurable Testbed (CoNNeCT) project utilized force-limited testing and analysis following the semi-empirical approach. This presentation presents the steps in performing a force-limited analysis and then compares the results to test data recovered during the CoNNeCT force-limited random vibration qualification test that took place at NASA Glenn Research Center (GRC) in the Structural Dynamics Laboratory (SDL) December 19, 2010 - January 7, 2011. A compilation of lessons learned and considerations for future force-limited tests is also included.

Staab, Lucas

Structural Dynamic Analysis of a Spacecraft Multi-DOF Shaker Table

Finite element enforced response analysis was performed on a three axis expander head shaker table to aid in the design of the table structure and vibration control system. The payload for this shaker system is a generic spacecraft with a multitude of flexible modes across a broad frequency band. A Craig-Bampton representation of the spacecraft was used to expedite analysis of multiple shaker table designs. The analysis examines the required forces in the actuators for a constant amplitude base acceleration sine sweep test, the resulting forces in the spacecraft and table attachment restraints, and the resulting accelerations on the spacecraft structure. The results show the spacecraft response is very high at the spacecraft center of gravity (CG) due to the high CG offset and cantilever effect of the low frequency spacecraft bending modes. The high response can be addressed by "notching" the input vibration levels to avoid over-testing the spacecraft. At frequencies above 25 Hz, the spacecraft modal effective masses are very small, and the response of the shaker table dominates the response. Anti-resonances of the shaker table in the frequency range of interest reduce the acceleration output and require much higher actuator forces to achieve the acceleration specification. These effects may require stiffening the shaker structure to move the modes out of the test frequency range or increasing the shaker table damping.

Pray, Carl

Structural Dynamic Analysis of a Spacecraft Multi-DOF Shaker Table

Finite element enforced response analysis was performed on a multiple degree of freedom expander head shaker table to aid in the design of the table structure and vibration control system. The payload for this shaker system is a spacecraft with a multitude of flexible modes across a broad frequency band. A Craig-Bampton representation of the spacecraft was used to expedite analysis of multiple shaker table designs. The analysis examines the required forces in the actuators for a constant amplitude base acceleration sine sweep test, the resulting forces in the spacecraft and table attachment restraints, and the resulting accelerations on the spacecraft structure. The results show the spacecraft response at low frequencies is very high near the tip due to the low order spacecraft bending and axial modes. The high response can be addressed by notching the input vibration levels to avoid overtesting the spacecraft. At frequencies above 25 Hz, the spacecraft modal effective masses are very small, and the response of the shaker table dominates the response. Anti-resonances of the shaker table in the frequency range of interest reduce the acceleration output and require much higher actuator forces to achieve the acceleration specification. These effects may require stiffening the shaker structure to move the modes out of the test frequency range or increasing the shaker table damping.

Pray, Carl