Measurement bias in self-heating x-ray free electron laser experiments from diffraction studies of phase transformation in titanium

X-ray self-heating is a common by-product of X-ray Free Electron Laser (XFEL) techniques that can affect targets, optics, and other irradiated materials. Diagnosis of heating and induced changes in samples may be performed using the x-ray beam itself as a probe. However, the relationship between conditions created by and inferred from x-ray irradiation is unclear and may be highly dependent on the material system under consideration. Here, we report on a simple case study of a titanium foil irradiated, heated, and probed by a MHz XFEL pulse train at 18.1 keV delivered by the European XFEL using measured x-ray diffraction to determine temperature and finite element analysis to interpret the experimental data. We find a complex relationship between apparent temperatures and sample temperature distributions that must be accounted for to adequately interpret the data, including beam averaging effects, multivalued temperatures due to sample phase transitions, and jumps and gaps in the observable temperature near phase transformations. The results have implications for studies employing x-ray probing of systems with large temperature gradients, particularly where these gradients are produced by the beam itself. Finally, this study shows the potential complexity of studying nonlinear sample behavior, such as phase transformations, where biasing effects of temperature gradients can become paramount, precluding clear observation of true transformation conditions.

Crystallography↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Multi-phase equation of state of ultrapure hafnium to 120 GPa

Hafnium (Hf) is an industrially important material due to its large neutron absorption cross-section and its high corrosion resistance. When subjected to high pressure, Hf phase transforms from its hexagonal close packed α-Hf phase to the hexagonal ω-Hf phase. Upon further compression, ω-Hf phase transforms to the body centered cubic β-Hf phase. In this study, the high pressure phase transformations of Hf are studied by compressing and decompressing a well-characterized Hf sample in diamond anvil cells up to 120 GPa while collecting x-ray diffraction data. The phase transformations of Hf were compared in both a He pressure transmitting medium (PTM) and no PTM over several experiments. It was found that the α-Hf to ω-Hf phase transition occurs at a higher pressure during compression and lower pressure during decompression with a helium (He) PTM compared to using no PTM. Finally, there was little difference in the ω-Hf to β-Hf phase transition pressure between the He PTM and no PTM. The equation of state was fit for all three phases of Hf and under both PTM and no-PTM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗