JOVE Pilot Research Study in Astronomy and Microgravity Sciences

The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. The first task was to measure finger joint angles inside space suit gloves. A preliminary survey identified three potential systems which could be used in the proposed study. In response to the current market situation, a glove for measuring the positions of the hand inside a space suit has been developed. A prototype of the glove has been constructed to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. Along gage is used to average the strain generated in the sensor due to bending This average strain produces an output signal proportional to the angle of the bend. The force sensor consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. The resistance of the ink is sensitive to pressure.

Strauss, Alvin M.

JOVE Pilot Research Study in Astronomy and Microgravity Sciences

The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. We have constructed a prototype of the glove to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. A long gage is used to average the strain generated in the sensor due to bending. This average strain produces an output signal proportional to the angle of the bend. The force sensor, FSR, is manufactured by Interlink. It consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. When the electrode makes contact, current flows through the conductive ink. The resistance of the ink pad is sensitive to pressure. We have also developed circuits for exciting and measuring the sensors. The current version requires a single sided twelve volt power supply which is one inch long and 0.4 inches in diameter.

Strauss, Alvin M.

Neural-Network Modeling Of Arc Welding

Artificial neural networks considered for use in monitoring and controlling gas/tungsten arc-welding processes. Relatively simple network, using 4 welding equipment parameters as inputs, estimates 2 critical weld-bead paramaters within 5 percent. Advantage is computational efficiency.

Anderson, Kristinn

EVA Glove Research Team

The goal of the basic research portion of the extravehicular activity (EVA) glove research program is to gain a greater understanding of the kinematics of the hand, the characteristics of the pressurized EVA glove, and the interaction of the two. Examination of the literature showed that there existed no acceptable, non-invasive method of obtaining accurate biomechanical data on the hand. For this reason a project was initiated to develop magnetic resonance imaging as a tool for biomechanical data acquisition and visualization. Literature reviews also revealed a lack of practical modeling methods for fabric structures, so a basic science research program was also initiated in this area.

Strauss, Alvin M.

A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging

A new method of analyzing the kinematics of joint motion is developed. Magnetic Resonance Imaging (MRI) offers several distinct advantages. Past methods of studying anatomic joint motion have usually centered on four approaches. These methods are x-ray projection, goniometric linkage analysis, sonic digitization, and landmark measurement of photogrammetry. Of these four, only x-ray is applicable for in vivo studies. The remaining three methods utilize other types of projections of inter-joint measurements, which can cause various types of error. MRI offers accuracy in measurement due to its tomographic nature (as opposed to projection) without the problems associated with x-ray dosage. Once the data acquisition of MR images was complete, the images were processed using a 3D volume rendering workstation. The metacarpalphalangeal (MCP) joint of the left index finger was selected and reconstructed into a three-dimensional graphic display. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones were obtained and processed by analyzing the screw motion of the MCP joint. Landmark positions were chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily two dimensional planar motion of this joint was then studied using a method of constructing coordinate systems using three (or more) points. A transformation matrix based on a world coordinate system described the location and orientation of a local target coordinate system. Future research involving volume rendering of MRI data focusing on the internal kinematics of the hand's individual ligaments, cartilage, tendons, etc. will follow. Its findings will show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove (power assisted) design for extravehicular activity (EVA).

Dickenson, Rueben D.

A preliminary structural analysis of space-based inflatable tubular frame structures

The use of inflatable structures has often been proposed for aerospace and planetary applications. The advantages of such structures include low launch weight and easy assembly. The use of inflatables for applications requiring very large frame structures intended for aerospace use are proposed. In order to consider using an inflated truss, the structural behavior of the inflated frame must be examined. The statics of inflated tubes as beams was discussed in the literature, but the dynamics of these elements has not received much attention. In an effort to evaluate the vibration characteristics of the inflated beam a series of free vibration tests of an inflated fabric cantilevers were performed. Results of the tests are presented and models for system behavior posed.

Main, John A.

Power assist EVA glove development

Structural modeling of the EVA glove indicates that flexibility in the metacarpophalangeal (MCP) joint can be improved by selectively lowering the elasticity of the glove fabric. Two strategies are used to accomplish this. One method uses coil springs on the back of the glove to carry the tension in the glove skin due to pressurization. These springs carry the loads normally borne by the glove fabric, but are more easily deformed. An active system was also designed for the same purpose and uses gas filled bladders attached to the back of the EVA glove that change the dimensions of the back of the glove and allow the glove to bend at the MCP joint, thus providing greater flexibility at this joint. A threshold control scheme was devised to control the action of the joint actuators. Input to the controller was provided by thin resistive pressure sensors placed between the hand and the pressurized glove. The pressure sensors consist of a layer of polyester film that has a thin layer of ink screened on the surface. The resistivity of the ink is pressure dependent, so an extremely thin pressure sensor can be fabricated by covering the ink patch with another layer of polyester film and measuring the changing resistance of the ink with a bridge circuit. In order to sense the force between the hand and the glove at the MCP joint, a sensor was placed on the palmar face of the middle finger. The resultant signal was used by the controller to decide whether to fill or exhaust the bladder actuators on the back of the glove. The information from the sensor can also be used to evaluate the effectiveness of a given control scheme or glove design since the magnitude of the measured pressures gives some idea of the torque required to bend a glove finger at the MCP joint. Tests of this actuator, sensor, and control system were conducted in an 57.2 kPa glove box by performing a series of 90 degree finger bends with a glove without an MCP joint assembly, a glove with the coil spring assembly, and with the four fingered actuated glove. The tests of these three glove designs confirm the validity of the model.

Main, John A.

A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging

A new method for analyzing the kinematics of joint motion using magnetic resonance imaging (MRI) is described. The reconstruction of the metacarpalphalangeal joint of the left index finger into a 3D graphic display is shown. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones are obtained and processed by analyzing the screw motion of the joint. Landmark positions are chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily 2D planar motion of this joint is then studied using a method of constructing coordinate systems using three or more points. A transformation matrix based on a world coordinate system describes the location and orientation of the local target coordinate system. The findings show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove design for EVA.

Dickenson, Reuben D.

Power assist EVA glove development

The design of the EVA glove is examined, emphasizing the development of a more flexible metacarpophalangeal (MCP) joint for the EVA glove. The analysis of the EVA glove MCP joint is reviewed and the glove design process is recapitulated. Experimental tests of the glove are summarized.

Main, John A.

MR imaging of hand microcirculation as a potential tool for space glove testing and design

The task of evaluating and designing space gloves requires accurate biomechanical characterization of the hand. The availability of magnetic resonance (MR) imaging has created new opportunities for in vivo analysis of physiological phenomena such as the relationship between circulation and fatigue. An MR imaging technique originally proposed to quantitatively evaluate cerebral perfusion has been modified to evaluate the capillary microcirculation in hand muscles. An experimental protocol was developed to acquire perfusion-weighted images in the hand before and after various levels of exercise. Preliminary results on the feasibility of applying the MR imaging technique to the study of microcirculation and fatigue in the hand are presented. The potential of this method for space glove testing and design is also discussed.

Peterson, Steven W.

A prototype power assist EVA glove

The most recent generation of space suit EVA gloves has addressed the problem of loose fit and stiffness in the fingers, but it remains difficult to build a glove assembly with low metacarpophalangeal joint stiffness. Fatigue due to constantly displacing the glove from a neutral position has been reported as the limiting factor in some EVA activities. This paper outlines an actuation system that uses gas filled bladders attached to the back of the EVA glove to provide the necessary force to bend the glove at the metacarpal joint, thus providing greater endurance during finger grasping tasks. A simple on-off controller senses hand movement through small pressure sensors between the finger and the glove restraint. The controller then fills or exhausts the bladders on the back of the glove to effectively move the neutral position of the glove as the hand inside moves.

Main, John A.

A generic expert system for materials processing in space

A generic expert system is described for inspecting materials processed in space (MPS). The system may be applied, with the appropriate knowledge base, to any of the nondestructive testing methods (NDT) which are appropriate to MPS. Regardless of the method being used, the inspection process consists of three tasks: (1) signal or image processing of the NDT output and feature extraction, (2) interpretation of features in terms of MPS discontinuities, and (3) evaluation of the quality of the MPS based upon industry standards. In contrast to rule based systems, this system represents its knowledge as multidimensional vectors and appropriate functions on them. Currently, the expert system accepts manual input of observed features. Once the expert system has been tested and compared to human expert inspectors, a vision front-end will be developed to complete automation of the expert MPS inspection system, based on visual discontuities. Then the data base will be extended to include a variety of other NDT methods. In addition to functional performance, ease of use was established through menu window driven input as well as flexibility in building, using and modifying data bases for different applications.

Andersen, Kristinn