Safe, High Power / Voltage Battery Design Challenges

NASA seeks safe, high performing battery module designs that can deliver 3C discharge rates continuously, achieve 160 Wh/kg, and is passively propagation resistant to a single cell thermal runaway event. One solution is presented that uses a patented oscillating heat pipe technology for thermal management. Combined with light weight packaging and a new commercially available gas permeable vent port, all 5 preliminary safety tests results performed to date are showing ample margins.

High power↗

Safe, High Power/Voltage Battery Module Design Challenges

NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.

Thermal runaway↗

Hazards Due to Overdischarge in Lithium-ion Cylindrical Cells in Multi-cell Configurations

Lithium-ion cells in the cylindrical Commercial-off-the-shelf 18650 design format were used to study the hazards associated with overdischarge. The cells in series or in parallel configurations were subjected to different conditions of overdischarge. The cells in parallel configurations were all overdischarged to 2.0 V for 75 cycles with one cell removed at 25 cycles to study the health of the cell. The cells in series were designed to be in an unbalanced configuration by discharging one cell in each series configuration before the start of test. The discharge consisted of removing a pre-determined capacity from the cell. This ranged from 50 to 150 mAh removal. The cells were discharged down to a predetermined end-of-discharge voltage cutoff which allowed the cell with lower capacity to go into an overdischarge mode. The cell modules that survived the 75 cycles were subjected to one overvoltage test to 4.4 V/cell.

Jeevarajan, Judith↗

Long Term Performance Retention Test Using High Power COTS NiCd and NiMH Cells

This slide presentation reviews the tests and results for performance retention of high powered commercial off the shelf (COTS) NiCd, and NiMH cells. Electromechanical actuators for space flight requires short duration high power batteries. The concern is that NiCd battery designs demonstrate an unfavorable power degradation after long periods of inactivity. Cycling can recover some of the decay, but this reduces the readiness that these batteries must have. Two 5-cell SubC stick test batteries ere chosen using NiCd and NiMH were tested and then the differences for charge maintenance were compared.

Hall, Dan↗

270V Battery Using COTS NiCd Cells For Manned Spacecraft

A high power (>35 kW at 215V), low capacity (5.2 Ah), and compact (45L) NiCd battery was developed for the X-38 Crew Return Vehicle (CRV), which is an experimental version of the lifeboat for the International Space Station (ISS). A simple design and innovative approach using a commercial-off-the-shelf (COTS) NiCd cell design enabled the design, qualification, and production of 4 flight units of this highly reliable and safe spacecraft battery to be achieved rapidly (2 years) and cheaply ($13M).

Darcy, Eric↗

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi↗

Li-ion EMU Battery Testing

A 45Ah Lithium ion (Li-Ion) battery comprised of 5 Yardney prismatic cells was evaluated to replace the silver-zinc cells in the Extra-vehicular Mobility Unit (EMU). Tests determined that the five cell battery can meet the mission objective of 500 duty cycles and maintain a minimum voltage of 16.0 V without an individual cell voltage dropping below 3.0V. Forty real time cycles were conducted to develop BOL trend data. Decision to switch to accelerated cycling for the remaining 460 cycles was made since Real Time cycling requires 1 day/cycle. Conclusions indicate that battery replacement would indeed be prudent.

Rehm, Raymond↗