Engineering PapersSearch

Engineering topics

Strangeway, R. J.

Publications and source records attributed to Strangeway, R. J..

At least 73 records · Page 4

The fine structure of Langmuir waves observed upstream of the bow shock at Venus

Highly structured Langmuir waves, also known as electron plasma oscillations, have been observed in the foreshock of Venus using the plasma wave experiment on the Galileo spacecraft during the gravity assist flyby on February 10, 1990. The Galileo wideband sampling system provides digital electric field waveform measurements at sampling rates up to 201,600 samples per second, much higher than any previous instrument of this type. The main Langmuir wave emission band occurs near the local electron plasma frequency, which was approximately 43 kHz. The Langmuir waves are observed to shift above and below the plasma frequency, sometimes by as much as 20 kHz. The shifts in frequency are closely correlated with the downstream distance from the tangent field line, implying that the shifts are controlled by the electron beam velocity. Considerable fine structure is also evident, with time scales as short as 0.15 milliseconds, corresponding to spatial scales of a few tens of Debye lengths. The frequency spectrum often consists of beat-type waveforms, with beat frequencies ranging from 0.2 to 7 kHz, and in a few cases, isolated wavepackets. The peak electric field strengths are approximately 1 mV/m. These field strengths are too small for strongly nonlinear processes to be important. The beat-type waveforms are suggestive of a parametric decay process.

Hospodarsky, G. B.

Fine structure of Langmuir waves observed upstream of the bow shock at Venus

Highly structured Langmuir waves, also known as electron plasma oscillations, have been observed in the foreshock of Venus using the plasma wave experiment on the Galileo spacecraft during the gravity assist flyby on February 10, 1990. The Galileo wideband sampling system provides digital electric field waveform measurements at sampling rates up to 201,600 samples per second, much higher than any previous instrument of this type. The main Langmuir wave emission band occurs near the local electron plasma frequency, which was approximately 43 kHz. The Langmuir waves are observed to shift above and below the plasma frequency, sometimes by as much as 20 kHz. The shifts in frequency are closely correlated with the downstream distance from the tangent field line, implying that the shifts are controlled by the electron beam velocity. Considerable fine structure is also evident, with timescales as short as 0.15 ms, corresponding to spatial scales of a few tens of Debye lengths. The frequency spectrum often consists of beat-type waveforms, with beat frequencies ranging from 0.2 to 7 kHz, and in a few cases, isolated wave packets. The peak electric field strengths are approximately 1 mV/m. These field strengths are too small for strongly nonlinear processes to be important. The beat-type waveforms are suggestive of a parametric decay process.

Hospodarsky, G. B.

VLF imaging of the Venus foreshock

VLF plasma wave measurements obtained from the Pioneer Venus Orbiter Electric Field Detector (OEFD) have been used to construct statistical images of the Venus foreshock. Our data set contains all upstream measurements from an entire Venus year (approximately 200 orbits). Since the foreshock VLF characteristics vary with Interplanetary Magnetic Field (IMF) orientation we restrict the study to IMF orientations near the nominal Parker spiral angle (25 to 45). Our results show a strong decrease in 30 kHz wave intensity with both foreshock depth and distance. There is also an asymmetry in the 30 kHz emissions from the upstream and downstream foreshocks. The ion foreshock is characterized by strong emissions in the 5.4 kHz OEFD channel which are positioned much deeper in the foreshock than expected from terrestrial observations. No activity is observed in the region where field aligned ion distributions are expected. ULF wave activity, while weaker than at Earth, shows similar behavior and may indicate the presence of similar ion distributions.

Crawford, G. K.

The Pioneer Venus Orbiter entry phase

In October, 1992 the Pioneer Venus Orbiter entered the atmosphere of Venus, ending nearly 14 years of observations at Venus. Prior to the entry into the atmosphere and subsequent loss of the spacecraft careful management of spacecraft resources had allowed the acquisition of much low altitude data over the nightside of the planet. The long duration of the Pioneer Venus mission has enabled us to study the ionosphere and atmosphere of Venus under different levels of solar activity.

Strangeway, R. J.

The magnetic state of the lower ionosphere during Pioneer Venus entry phase

During the entry phase of the Pioneer Venus Orbiter (PVO), defined as that period at the end of mission in 1992 when the periapsis fell below 185 km, the magnetometer made repeated measurements throughout the post midnight ionosphere until about 0430 LT. In this region the magnetic field is generally stronger at comparable altitudes than it was earlier at times of higher solar activity. This increase combined with a decrease in electron density causes the ratio of the magnetic pressure to thermal pressure to approach unity at altitudes above 200 km, whereas it was much lower than unity at these altitudes during solar maximum. From 160-200 km the magnetic field pressure exceeds that of the ionospheric plasma quite unlike the usual conditions seen at the beginning of the mission. At lowest altitudes below 150 km, however, the field becomes weaker and hence no evidence for a planetary magnetic field is found.

Russell, C. T.

The nightside ionosphere of Venus under varying levels of solar EUV flux

Solar activity varied widely over the 14 year lifetime of the Pioneer Venus Orbiter (PVO), and these variations directly affected the properties of the nightside ionosphere. At solar maximum, when solar EUV was largest, the Venus ionosphere was found to extend to highest altitudes and nightward ion transport was the main source of the nightside ionosphere. At solar minimum, nightward ion transport was reduced, and electron precipitation was thought to be the main source. In this study, we have attempted a separation of spatial variations from temporal variations by examining the altitude profiles of the magnetic field, and electron density and temperature for three different solar EUV flux ranges. In the upper ionosphere and near-planet magnetotail (h greater than 1800 km), the solar EUV flux effects are significant. The electron density decreases about an order of magnitude from high to low EUV flux, while the electron temperature at least doubles. The magnetic field also increases 2 - 3 nT. In the lower ionosphere (200 - 600 km), lower EUV fluxes are associated with slightly reduced density, and higher temperature. These results are in accord with recent entry phase observations, where the electron density measured above the ionospheric density peak is lower than that observed at solar maximum during the early Pioneer Venus mission.

Ho, C. M.

Plasma waves observed at low altitudes in the tenuous Venus nightside ionosphere

The Pioneer Venus (PV) Orbiter Electric Field Detector (OEFD) measured many plasma wave bursts throughout the low altitude ionosphere during the final entry phase of the spacecraft. Apart from 100 Hz bursts observed at very low altitudes (approx. 130 km), the bursts fall into two classes. The first of these is a wideband signal that is observed in regions of low magnetic field, but average densities, in comparison to the prevailing ionospheric condition. This wideband signal is not observed in the 30 kHz channel of the OEFD, but is resricted to the 5.4 kHz channel and lower. Since these bursts are observed with roughly constant burst rate above 160 km altitude, we attribute them to ion acoustic mode waves generated by precipitating solar wind electrons. The second type of signal is restricted to 100 Hz only, and is observed in the regions of low electron beta, consistent with whistler-mode waves. These waves could be generated by lightning in the Venus atmosphere if the vertical component of the magnetic field greater than 3.6 nT. Because the ionosphere is very different during the entry phase, compared to the ionosphere as observed early in the Pioneer Venus mission, any conclusions regarding the source of the plasma waves detected during entry phase cannot be applied directly to the earlier observations.

Strangeway, R. J.

Observation of intense wave bursts at very low altitudes within the Venus nightside ionosphere

Intense ELF (100 Hz) bursts were detected by the Pioneer Venus (PV) Orbiter plasma wave instrument during the final operations of the spacecraft prior to atmospheric entry. These bursts were detected at approx. 130 km altitude around 0400 local time. The wave activity lasted for several tens of seconds. Furthermore the bursts were not symmetric about periapsis, unlike instrument noise caused by neutral impacts on the spacecraft. The bursts had a vertical attenuation scale height of the order 1 km, consistent with that expected for whistler-mode waves propagating through a collisional ionosphere. Since the decay of the signals appears to be due to attenuation, the source must persist for several tens of seconds. The wave bursts could therefore be the signature of electromagnetic radiation entering the bottomside ionosphere from several distant sources, as would be expected if lightning were a relatively persistent phenomenon within the Venus atmosphere.

Strangeway, R. J.

Evidence for Langmuir oscillations and a low density cavity in the Venus magnetotail

We report the discovery of Langmuir oscillations in a very low plasma density region in the Venus magnetotail. These waves are observed more often at 30 kHz, but also at 5.4 kHz indicating densities as low as 0.3 cu cm in the central tail lobe. The Langmuir probe on board the Pioneer Venus Orbiter cannot resolve such a low plasma density. We use the magnetic field strength and the assumption of total pressure balance to infer the electron temperature as a test of the Langmuir wave interpretation. By investigating the spatial distribution of this wave activity we find that the plasma cavity is ordered in a coordinate system defined by the interplanetary magnetic field and is found at either side of the central tail current sheet.

Ho, C. M.

The Magnetic State of the Lower Ionosphere During Pioneer Venus Entry Phase

During the entry phase of the Pioneer Venus Orbiter, defined as that period at the end of mission in 1992 when the periapsis fell below 185 km, the magnetometer made repeated measurements throughout the post midnight ionosphere until about 0430 LT. In this region the magnetic field is generally stronger at comparable altitudes than it was earlier at times of higher solar activity. This increase combined with a decrease in electron density causes the ratio of the magnetic pressure to thermal pressure to approach unity at altitudes above 200 km, whereas it was much lower than unity at these altitudes during solar maximum. From 160-200 km the magnetic field pressure exceeds that of the ionospheric plasma quite unlike the usual conditions seen at the beginning of the mission. At lowest altitudes below 150 km, however, the field becomes weaker and hence no evidence for a planetary magnetic field is found.

Russell, C. T.

Plasma Waves Observed at Low Altitudes in the Tenuous Venus Nightside Ionosphere

The Pioneer Venus Orbiter Electric Field Detector (OEFD) measured many plasma wave bursts throughout the low altitude ionosphere during the final entry phase of the spacecraft. Apart from 100 Hz bursts observed at very low altitudes (approx. 130 km), the bursts fall into two classes. The first of these is a wideband signal that is observed in regions of low magnetic field, but average densities, in comparison to the prevailing ionospheric condition. This wideband signal is not observed in the 30 kHz channel of the OEFD, but is restricted to the 5.4 kHz channel and lower. Since these bursts are observed with roughly constant burst rate above 160 km altitude, we attribute them to ion acoustic mode waves generated by precipitating solar wind electrons. The second type of signal is restricted to 100 Hz only, and is observed in regions of low electron beta, consistent with whistler-mode waves. These waves could be generated by lightning in the Venus atmosphere if the vertical component of the magnetic field greater than 3.6 nT. Unfortunately, the spacecraft spin axis is mainly horizontal, and only that component of magnetic field can be measured. Alternatively, the 100 Hz bursts could be generated locally through gradient drift instabilities, provided the ambient magnetic field is horizontal. Because the ionosphere is very different during the entry phase, compared to the ionosphere as observed early in the Pioneer Venus mission, any conclusions regarding the source of the plasma waves detected during entry phase cannot be applied directly to the earlier observations.

Strangeway, R. J.

Observation of Intense Wave Bursts at Very Low Altitudes Within the Venus Nightside Ionosphere

Intense ELF (100 Hz) bursts were detected by the Pioneer Venus Orbiter plasma wave instrument during the final operations of the spacecraft prior to atmospheric entry. These bursts were detected at approx. 130 km altitude around 0400 local time. The wave activity lasted for several tens of seconds. Furthermore the bursts were not symmetric about periapsis, unlike instrument noise caused by neutral impacts on the spacecraft. The bursts had a vertical attenuation scale height of the order 1 km, consistent with that expected for whistler-mode waves propagating through a collisional ionosphere. Since the decay of the signals appears to be due to attenuation, the source must persist for several tens of seconds. The wave bursts could therefore be the signature of electromagnetic radiation entering the bottomside ionosphere from several distant sources, as would be expected if lightning were a relatively persistent phenomenon within the Venus atmosphere.

Strangeway, R. J.

Evidence for Langmuir Oscillations and a Low Density Cavity in the Venus Magnetotail

We report the discovery of Langmuir oscillations in a very low plasma density region in the Venus magnetotail. These waves are observed more often at 30 kHz, but also at 5.4 kHz indicating densities as low as 0.3/cu cm in the central tail lobe. The Langmuir probe on board the Pioneer Venus Orbiter cannot resolve such a low plasma density. We use the magnetic field strength and the assumption of total pressure balance to infer the electron temperature as a test of the Langmuir wave interpretation. By investigating the spatial distribution of this wave activity we find that the plasma cavity is ordered in a coordinate system defined by the interplanetary magnetic field and is found at either side of the central tail current sheet.

Ho, C. M.

VLF emissions in the Venus foreshock - Comparison with terrestrial observations

An examination is conducted of ELF/VLF emissions observed in the solar wind upstream of the Venus shock, for the 100 Hz-30 kHz range, using data from the Pioneer Venus Orbiter's electric field detector and magnetometer instruments. Detailed comparisons are made with terrestrial measurements for both the electron and ion foreshocks. The results obtained support the Crawford et al. (1990) identification of the Venus electron foreshock emissions as electron plasma oscillations, whose waves are generated in situ and act to isotropize the electron distributions.

Crawford, G. K.

On the instability and energy flux of lower hybrid waves in the Venus plasma mantle

Waves generated near the lower hybrid resonance frequency by the modified two stream instability have been invoked as a possible source of energy flux into the topside ionosphere of Venus. These waves are observed above the ionopause in a region known as the plasma mantle. The plasma within the mantle appears to be a mixture of magnetosheath and ionospheric plasmas. Since the magnetosheath electrons and ions have temperatures of several tens of eV, any instability analysis of the modified two stream instability requires the inclusion of finite electron and ion temperatures. Finite temperature effects are likely to reduce the growth rate of the instability. Furthermore, the lower hybrid waves are only quasi-electrostatic, and the energy flux of the waves is mainly carried by parallel Poynting flux. The magnetic field in the mantle is draped over the ionopause. Lower hybrid waves therefore cannot transport any significant wave energy to lower altitudes, and so do not act as a source of additional heat to the topside ionosphere.

Strangeway, R. J.

Magnetic field properties of the intermediate transition of the Venus ionosheath

Results of a statistical analysis of the magnetic properties of the intermediate transition of the Venus ionosheath based on the magnetic field data of the Pioneer Venus Orbiter are reported. It is found that the transition is often characterized by a substantial decrease in magnetic field intensity and an accompanying rotation to a direction that is more closely aligned with the sun-Venus axis. In other cases, the 30 kHz bursts occur outside a region of enhanced magnetic field reminiscent of the magnetic barrier external to the Venus dayside ionopause. The rotation of the magnetic field toward the sun-Venus line associated with the 30 kHz bursts is also evident here, but generally the conditions change more gradually. Possible mechanisms of these variations and ionospheric plasma expansion are examined.

Perez-De-tejada, H.

Wave properties near the subsolar magnetopause - Pc 3-4 energy coupling for northward interplanetary magnetic field

Strong slow mode waves in the Pc 3-4 frequency range are found in the magnetosheath close to the magnetopause. We have studied these waves at one of the ISEE subsolar magnetopause crossings using the magnetic field, electric field, and plasma measurements. We use the pressure balance at the magnetopause to calibrate the Fast Plasma Experiment data versus the magnetometer data. When we perform such a calibration and renormalization, we find that the slow mode structures are not in pressure balance and small scale fluctuations in the total pressure still remain in the Pc 3-4 range. Energy in the total pressure fluctuations can be transmitted through the magnetopause by boundary motions. The Poynting flux calculated from the electric and magnetic field measurements suggests that a net Poynting flux is transmitted into the magnetopause. The two independent measurements show a similar energy transmission coefficient. The transmitted energy flux is about 18 percent of the magnetic energy flux of the waves in the magnetosheath. Part of this transmitted energy is lost in the sheath transition layer before it enters the closed field line region. The waves reaching the boundary layer decay rapidly. Little wave power is transmitted into the magnetosphere.

Song, P.

Venus lightning - An update

The evidence for Venus lightning comes from three distinct sources: the Venera 11-14 landers, the Venera 9 orbiter and the Pioneer Venus orbiter. The largest data set and the one being analyzed most thoroughly at present comes the VLF electric field experiment on PVO spacecraft. Recent results show that the Poynting flux out of the atmosphere is consistent with that expected from a terrestrial sized source of lightning or possibly one much greater. Estimates of the flash rate from the statistics of impulsive signals also points to a source that is stronger than the terrestrial source. Ongoing studies of the polarization of the signals and their properties relative to their direction of propagation as well as a recalibration of the Pioneer Venus star sensor promise to provide continuing information on this phenomenon.

Russell, C. T.