Engineering PapersSearch

Engineering topics

Stoller, F. W.

Publications and source records attributed to Stoller, F. W..

Photogrammetry Of A Parabolic Antenna

Surface measured with accuracy better than 10 to the negative fifth power times diameter. Report describes use of advanced close-range photogrammetry to determine deviations of 34-m-diameter antenna main reflector and subreflector from nominal paraboloidal shapes. Measurements enable removal of linear offsets and angular misalignments of subreflector, with consequent increase of 4 percent in aperture efficiency.

Merrick, W. D.

Structural design options for the new 34 meter beam waveguide antenna

In addition to the successful network of 34 m High Efficiency antennas recently built by JPL, the Deep Space Network (DSN) is embarking on the construction of a 34 m high performance, research and development antenna with beam waveguide optics at the Venus site. The construction of this antenna presents many engineering challenges in the area of structural, mechanical, RF, and pointing system design. A set of functional and structural design requirements is outlined to guide analysts in the final configuration selection. Five design concepts are presented covering both the conventional center-fed beam optics as well as the nonconventional, by-pass beam configuration. The merits of each concept are discussed with an emphasis on obtaining a homologous design. The preliminary results of structural optimization efforts, currently in progress, are promising, indicating the feasibility of meeting, as a minimum, all X-band (8.4 GHz) requirements, with a goal towards meeting Ka-band (32 GHz) quality performance, at the present budget constraints.

Katow, S.

Rivited panel surface measurement using photogrammetry

Two riveted antenna panels on rings number 3 and 9 were removed from the 34m antenna at DSS-15, fixed in the leveled position and the surface was photographed indoors. The results from this pilot photogrammetric demonstration and diagnostics of panel surface contours, are presented. The photogrammetric network for each panel incorporated eight photographs, two from each of four camera stations and observed over 200 targets. The accuracy (1 sigma) of the XYZ coordinates for the error ellipsoids was + or - 0.013 mm (0.0005 inch). This level of precision relative to the object size corresponds roughly to 1 part in 250,000 which is superior to conventional dial sweep-arm template techniques by at least a factor of 4.

Merrick, W. D.

Intermodulation Product Levels in Flame-sprayed Materials

A preliminary investigation on intermodulation product (IMP) levels of fiberglass-backed flame-sprayed surfaces was completed. The purpose was to demonstrate the use of modified techniques and materials in combustion flame spraying of formed surfaces in reducing intermodulation products. The approach used improved metal wire stock without impurities or with smaller droplet sizes, high-temperature release agents, wire stock with low electrical resistance, variations in spraying distances, and intense buffing processes which amalgamate the material gaps and droplets in an effort to fabricate IMP-free lightweight and low cost subreflectors. Positive material candidates were found with an IMP level around -150 dB, which is comparable to solid aluminum surfaces used as a reference.

Yung, C. S.

Analysis of building heating and cooling

Energy Conservation Program (ECP) gives design engineer methodology and easy-to-use computer program for simulating hourly thermal characteristics over full year for individually characterized zones within building. Inexpensive system can be used to develop thermal model of building to aid selection of most suitable and economical heating and cooling system for building

Chai, V. W.

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.

Automatic, computerized testing of bolts

System for testing bolts with various platings, lubricants, nuts, and tightening procedures tests 200 fasteners, and processes and summarizes the results, within one month. System measures input torque, nut rotation, bolt clamping force, bolt shank twist, and bolt elongation, data is printed in report form. Test apparatus is described.

Carlucci, J., Jr.

Structural thermal-control coatings

Specifications have been formulated for application of thermal-control paints on large radar antenna structures exposed to solar radiation. The paint minimizes thermally induced mechanical deflections and glare of incident solar radiation.

Stoller, F. W.

Low speed, long term tracking electric drive system has zero backlash

Electric drive system provides low speed, long term tracking of targets that move at a sidereal rate. It utilizes eddy-current energized actuators that are free from radio frequency interference generation and a solid state feedback amplifier with provisions for antibacklash biasing.

Richter, H. L.