Engineering Papers⌕ Search

Engineering topics

Stockli, Martin P.

Publications and source records attributed to Stockli, Martin P..

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations

High brightness, negative hydrogen ion sources are used extensively in scientific facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Several well-known facilities now have considerable experience with operating a variety of sources such as RF-, filament-, magnetron- and Penning-type H- ion sources. These facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly on cyclotrons and, most recently, the CERN-LINAC-1 injector. This report first summarizes the current performance of these ion sources in routine, daily operations with attention toward source service-periods and availability metrics. Sustainability issues encountered at each facility are also reported and categorized to identify areas of common concern and key issues. Recent ion source improvements to address these issues are also discussed as well as plans for meeting future facility upgrade requirements.

Welton, Robert F.↗

Recent performance of the SNS H - ion source with a record long run

The Spallation Neutron Source (SNS) accelerator system includes a 65 keV H - injector, a 2.5 MeV radio frequency quadrupole (RFQ), a 1 GeV linac chain (DTL-CCL-SCL) and an accumulator ring. The H - injector consists of an RF-driven, Cs-enhanced, multi-cusp H - ion source and a compact, two-lens electrostatic low energy beam transport (LEBT). In 2018, a new RFQ was installed in place of the original RFQ along with upgraded ion source support infrastructure. This paper presents the operational performance and some highlights of beam studies with the SNS ion source since the new RFQ was put into operation. SNS routinely operates at 1.4 MW average beam power for three run cycles per year. During the most recently finished run, FY20B, we operated a single source for the entire run spanning ~4 months with a >99.5% availability. A single dose of cesiation was conducted during the ion source startup which yielded ≥54 mA current for the entire run with just few minor adjustments of parameters.

Han, Baoxi↗

H- ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced by spallation of liquid Hg due to bombardment of short (~1µs), intense (~35 A) pulses of protons delivered at 60 Hz from a storage ring which is fed by a high-intensity, 1 GeV H- LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50-60 mA of H- ions with a duty-factor of 6% for maintenance-free runs of ~120 days with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting these achievements: this report provides some historical highlights of this effort, describes our current ion source testing facilities, discusses the goals of the program and finally provides a snapshot of some of our ongoing R&D activities. In particular, we have recently simplified and improved the reliability of the plasma ignition gun for the external antenna ion source which is discussed in detail.

Welton, Robert F.↗

Tests of Cs-Free Operation of the SNS RF H⁻ Ion Sources

Tests were performed at SNS in collaboration with visiting colleagues from ISIS, UK to evaluate the uncesiated beam performance of the SNS RF H⁻ ion sources. Two spare experimental sources, one with internal antenna and one with external antenna were used for the tests. The beam currents achieved with Cs-free operations accounted for about 1/3 to 1/2 of the beam currents produced with cesiated operations. ~17 mA uncesiated H⁻ current was demonstrated within the tested RF power range up to 65 kW with the internal antenna source and ~15 mA with up to 40 kW RF with the external antenna source. In Cs-free operations, the power supply for the electron dumping electrode was loaded down below its set voltage but was not too drastic to tamper the operation.

Han, Baoxi↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗