Experimental findings from zero-tank net positive suction head operation of the J-2 hydrogen pump
The results of a series of liquid hydrogen turbopump tests to demonstrate the feasibility of zero-tank net positive suction head are presented. A J-2 engine hydrogen pump and S-IVB stage fuel feed system were used for this investigation. The pump was operated at flows and speeds equivalent to normal J-2 engine operating conditions and at hydrogen bulk temperatures between 39 and 45 R. These tests show zero-tank not positive suction head to be a realistic operating mode that should be considered for future applications.
Stinson, H. P.↗