Engineering PapersSearch

Engineering topics

Stewart, W. F.

Publications and source records attributed to Stewart, W. F..

Resources Available for Hazards Analysis of Aerospace Fluids

In recent years, the legislative and executive branches of the federal government have pushed to make government more efficient and responsive to the needs of the marketplace. One of these initiatives, Public Law 104-113, also known as the National Technology Transfer and Advancement Act of 1995 (NTTAA), is designed to accelerate technology transfer to industry and promote government-industry partnership. Summarized, NTTAA states that '... all Federal agencies and departments shall use technical standards that are developed or adopted by voluntary consensus standards bodies, using such technical standards as a means to carry out policy objectives or activities determined by the agencies and departments. Government agencies must now determine if their in-house requirement-setting activities are sufficiently unique that no public interest is served by having them adopted by a voluntary consensus organization (VCO), or if not, to use or develop voluntary consensus standards. The Office of Management and Budget (OMB) is chartered by the law to monitor federal agency progress and report the results to Congress. In response to NTTAA, agency-wide oxygen and hydrogen safety standards sponsored by the NASA Headquarters (HQ) Office of Safety and Mission Assurance (OSMA) were obvious choices for early adoption by VCOs. In 1996, HQ sought assistance from the Johnson Space Center (JSC) White Sands Test Facility (WSTF), the technical lead for development of these safety standards, to evaluate their adoption by VCOs. At that time, WSTF-developed propellant hazards manuals were likewise identified for possible VCO adoption. Subsequently, WSTF was asked to represent NASA for development of an international ISO safety standard for hydrogen use. Concurrent with these WSTF standards activities are related efforts to develop and publish propellant hazards analysis protocols and safety courses for the industrial, propellant use of oxygen, hydrogen, and hypergols. This paper reports on these efforts and describes WSTF's overall voluntary consensus standards program to coordinate the interchange of NASA's propellant hazards and safety information with industry.

Woods, S. S.

Experiment to determine properties of packed particle beds and regenerators at cryogenic temperatures

Studies related to the development of magnetic refrigeration and heat pump systems in temperature ranges from 4 K to ambient temperature and above have been conducted, taking into account the testing of the properties of packed-particle beds and regenerators at cryogenic temperatures as low as 4 K as an essential part of these studies. The present paper provides a description of the developed experimental apparatus and presents the results of recent measurements on packed-particle beds in the liquid helium and liquid nitrogen temperature ranges. Attention is given to a schematic of the apparatus and the data acquisition system, the various modes of gas flow, a schematic of a typical test bed with thermocouple positions, the calculation of transient heat transfer rates at different positions in the bed, the governing equations, and the procedures used for solving these equations.

Barclay, J. A.

Automatic Calibration Systems

A continuous requirement exists for calibration and environmental testing of instruments in use at multitude of test facilities at Langley Research Center. Brief summarizes several automated systems available for calibration of research instruments to include: six-component balance, multimeter, amplifier, pyrometer, voltage-controlled oscillator, pressure transducer and accelerometer.

Ferris, A. T.

Modulated infrared radiant source

A modulated, infrared radiant energy source was developed to calibrate an airborne nadir-viewing pressure modulated radiometer to be used to detect from Earth orbit trace gases in the troposphere. The technique used an 8 cm long, 0.005 cm diameter platinum-iridium wire as an isothermal, thin line radiant energy source maintained at 1200 K. A + or - 20 K signal, oscillating at controllable frequencies from dc to 20 Hz, was superimposed on it. This periodic variation of the line source energy was used to verify the pressure modulated radiometer's capability to distinguish between the signal variations caused by the Earth's background surface and the signal from the atmospheric gases of interest.

Stewart, W. F.

Calibration target for temperature radiometer

Technique measures temperature/voltage drop characteristics of very thin filament. With constant current running through filament, voltage drop is recorded at various temperatures, as measured by calibrated thermocouple.

Edwards, S. F.

A hot wire radiant energy source for mapping the field of view of a radiometer

The design and performance of a calibration device that allows the measurement of a radiometer's field of view are described. The heart of the device is a heated 0.0254-mm (0.001-inch) diameter filament that provides a variable, isothermal line source of radiant energy against a cold background. By moving this discrete line source across the field of view of a radiometer, the radiometer's spatial response can be completely mapped. The use of a platinum filament provides a durable radiation source whose temperature is stable and repeatable to 10 K over the range of 600 to 1200 K. By varying the energy emitted by the filament, the field of view of radiometers with different sensitivities (or multiple channel radiometers) can be totally mapped.

Edwards, S. F.

Apparatus description and data analysis of a radiometric technique for measurements of spectral and total normal emittance

The development of a radiometric technique for determining the spectral and total normal emittance of materials heated to temperatures of 800, 1100, and 1300 K by direct comparison with National Bureau of Standards (NBS) reference specimens is discussed. Emittances are measured over the spectral range of 1 to 15 microns and are statistically compared with NBS reference specimens. Results are included for NBS reference specimens, Rene 41, alundum, zirconia, AISI type 321 stainless steel, nickel 201, and a space-shuttle reusable surface insulation.

Edwards, S. F.

Calibration of small gauge thermocouples.

A technique has been developed to dynamically calibrate fine wire thermocouples of 0.025 mm diam and smaller to 1625 K in less than 10 sec. In this method, the varying physical parameters present under typical dynamic heating conditions are simulated, and therefore, wire deterioration can be related to time, temperature, pressure, and atmosphere. A description of the equipment and procedures is given along with the preliminary results that correlate well with thermoelectric theory.

Stewart, W. F.