Engineering Papers⌕ Search

Engineering topics

Stern, R. A.

Publications and source records attributed to Stern, R. A..

At least 19 records

A far-ultraviolet flare on a Pleiades G dwarf

The Hubble Space Telescope/Faint Object Spectrograph (HST/FOS) recorded a remarkable transient brightening in the C IV lambda lambda 1548,50 emissions of the rapidly rotating Pleiades G dwarf H II 314. On the one hand the 'flare' might be a rare event luckily observed; on the other hand it might be a bellwether of the coronal heating in very young solar-mass stars. If the latter, flaring provides a natural spin-down mechanism through associated sporadic magnetospheric mass loss.

Ayres, T. R.↗

Ginga observations of X-ray flares on Algol

The Ginga X-ray satellite observed Algol (Beta Per) for 2 days in 1989 January, including both the primary optical eclipse and most of the secondary eclipse. We derive upper limits of about 20 and 10 percent, respectively, for the eclipsed flux fraction during the two eclipses. A large flare lasting over 12 hr was seen prior to and during secondary eclipse. High-temperature Fe line emission is clearly detected in the proportional counter data. The Fe line equivalent width is variable during the flare, ranging from 0.4-1.0 keV. Except for two intervals during the flare rise, the observed equivalent width is lower than predicted using solar abundances and an optically thin plasma model. Similar behavior has also been observed by Ginga in a large flare on UX Ari: in both events, opacity effects at line center may be playing a significant role. Loop model analysis of the large flare suggests that it involves a substantially longer loop or loops than a shorter duration Algol flare seen with Exosat.

Stern, R. A.↗

Coordinated Ginga, IUE, and VLA observations of stellar activity in Sigma(2) Coronae Borealis

Observations of the active cool star binary system Sigma(2) Corona Borealis with the Large Area Counters on the Ginga X-ray satellite over 2.5 d, or about two orbital periods, are reported. Throughout the observations, Sigma(2) CrB exhibited X-ray variability on time scales ranging from tens of minutes to hours. The X-ray light curve shows evidence of flaring during the course of the observations. The summed X-ray pulse height spectrum from flaring events compared with similar spectra from quiescent periods indicates an increase in coronal temperature. Periodogram analysis of the entire X-ray light curve shows a possible periodicity at about 0.40-0.44 d, with no strong signal at the orbital period or 1/2 of the orbital period. Coordinated multiwavelength observations of IUE and the VLA indicate both UV and microwave flaring during one X-ray outburst. The quiescent microwave spectrum is not consistent with a thermal gyrosynchrotron process; nonthermal gyrosynchrotron radiation is argued to be the most likely emission process.

Stern, R. A.↗

Einstein Observatory magnitude-limited X-ray survey of late-type giant and supergiant stars

Results are presented of an extensive X-ray survey of 380 giant and supergiant stars of spectral types from F to M, carried out with the Einstein Observatory. It was found that the observed F giants or subgiants (slightly evolved stars with a mass M less than about 2 solar masses) are X-ray emitters at the same level of main-sequence stars of similar spectral type. The G giants show a range of emissions more than 3 orders of magnitude wide; some single G giants exist with X-ray luminosities comparable to RS CVn systems, while some nearby large G giants have upper limits on the X-ray emission below typical solar values. The K giants have an observed X-ray emission level significantly lower than F and F giants. None of the 29 M giants were detected, except for one spectroscopic binary.

Maggio, A.↗

Ginga observations of a long-duration X-ray flare in the Algol system

Algol was observed by the Ginga X-ray satellite for about 2 days in January 1989, including both the primary and most of the secondary optical eclipses. No evidence for X-ray eclipses was seen. A large flare lasting over 12 h was detected prior to and during secondary eclipse. The flare began with a peak temperature of about 69 MK, gradually decaying to about 36 MK. Variable Fe line emission at 6.7 keV ws observed. The Fe line equivalent width is in clear disagreement with theoretical predictions for an optically thin plasma.

Stern, R. A.↗

Co-ordinated Ginga, IUE and VLA observations of flaring activity in sigma-squared CrB

The RS CVn system sigma-squared CrB was observed by the Ginga X-ray satellite for a period of 2.5 days, or approximately 2 binary orbits. Sigma-squared CrB exhibited almost continuous X-ray variability on time scales ranging from minutes to days, including several 'flare-like' episodes with increased coronal temperature. The average count rate was 4.2 +/- 1.2 cts/s (1.7-11.0 keV) corresponding to L(x) of about 10 to the 29.6th erg/s (2-10 keV). Coordinated observations with IUE and the VLA indicate microwave and ultraviolet flaring associated with one X-ray flare.

Stern, R. A.↗

The Einstein Observatory survey of stars in the Hyades cluster region

The paper reports the results of an extensive X-ray study of the Hyades region and improves on previous studies by using refined X-ray source detection algorithms and the complete set of Einstein Observatory IPC exposures covering the Hyades cluster region (a total of 63 1 x 1 deg images). Maximum likelihood integral X-ray luminosity functions were computed for the Hyades stars for given color index (B-V) ranges. The present results agree substantially with a previous survey about the ubiquity of the stellar activity in the Hyades cluster, especially among solar-type stars. The result of Stern et al. (1981) that stellar X-ray emission is dependent on stellar age is confrimed.

Micela, G.↗

X-ray objective grating spectrograph

A grazing incidence X-ray spectrograph for investigating the spectra of cosmic X-ray sources is described. The overall instrument design is reviewed, and the key components of the spectrograph, including the gratings, telescope, and detector, are examined. Preliminary performance measurements are reported and plans for the instrument are addressed.

Catura, R. C.↗

Ultraviolet and extreme ultraviolet response of charge-coupled-device detectors

Results of a program to enhance the ultraviolet and extreme ultraviolet response of charge-coupled devices are presented. The ultimate goal of the program is to develop a large format device with both high and stable quantum efficiency from 100 to 3000 A that can be used as a windowless imaging detector in a space environment. Ultraviolet quantum efficiency measurements have been made for several ion-implanted and laser-annealed test CCDs. Quantum efficiencies as high as 22 percent at 2500 A, where the absorption depth in silicon is about 55 A, have been observed in one such test CCD. Quantum efficiency measurements of standard back-illuminated CCDs are also presented.

Stern, R. A.↗

On the dividing line for stellar coronae

A possible explanation is proposed for the observation that late-type stars falling in a certain region of the H-R diagram exhibit no X-ray emission and hence appear not to have coronae. It is argued that, due to the low surface gravity of these stars, the hot X-ray emitting loops in their atmospheres simply become cool and emit at longer wavelengths. This argument is demonstrated quantitatively by considering the effect on a typical solar loop of scaling it up to parameters appropriate to a supergiant.

Antiochos, S. K.↗

Modeling of coronal X-ray emission from active cool stars. I Hyades cluster

X-ray pulse height spectra of the most active cool stars in the Hyades cluster obtained with the Einstein IPC cannot be satisfactorily fitted using isothermal thin plasma emission models. Addition of a second isothermal component provides acceptable fits. However, a more physically meaningful set of coronal parameters is provided by models which consist of an ensemble of loops wih a single maximum temperature, but with the temperature distribution within the loop determined by loop physics. Such models have been successfully fitted to the IPC pulse height spectra. Constraints on loop parameters are discussed for the F-G dwarfs BD + 14 deg 693, BD + 14 deg 690, BD + 15 deg 640, and 71 Tau. Models with a large variation of loop cross section from base to top do not fit the data. A consistent physical description is an ensemble of small high-pressure loops of similar maximum temperature which dominate the coronal X-ray spectrum.

Stern, R. A.↗

EUV astronomical spectroscopy with CCD detectors

The applicability of CCD detectors to astronomical extreme ultraviolet (EUV) spectroscopy (100-1250 A) is discussed. The advantages of CCDs in this spectral region include internal electron yield, the potential for very high quantum efficiency (about 50-90 percent), and broad wavelength response. Visible light suppression is achieved by a combination of low grating scattering, greater than unity electron yield in the EUV, and various filter techniques. For the current generation of CCDs, detection of only a few EUV photons will rapidly overwhelm the read noise; thus, for all practical S/N ratios used in astronomical spectroscopy, read noise will be negligible compared to the poisson statistics of the detected photons. A model based on experimental data for the quantum efficiency and electron yield of CCDs in the EUV is discussed.

Stern, R. A.↗

Soft X-ray polychromator for the Solar Maximum Mission

The XRP was designed to measure the following temporal and spatial properties of the active and flaring Sun: electron temperature, departures from steady state, ion kinetic temperatures, and electron density. The Bent Crystal Spectrometer (BCS) is capable of measuring the broadening and blue shifts often observed in the impulsive phase of flares. The six simultaneous line fluxes indicative of six different temperatures of formation observable by the Flat Crystal Spectrometer (FCS) allows the derivation of the differential emission measure of the plasma at each raster point. During the operational periods of the XRP hundreds of flares of C-level (GOES classification) were observed and brighter in both the FCS and BCS, including 5 X-flares. Associated theoretical work in atomic physics, stimulated in part by the promise of XRP measurements, has benefitted from the experimental data on solar plasmas which the XRP has provided in abundance.

Haisch, B. M.↗

An X-ray survey of beta Cephei stars

Results of an X-ray survey of beta Cephei stars carried out with the Imaging Proportional Counter are reported. Three of six surveyed beta Cephei stars observed was detected with an X-ray luminosity (LX) lying in the range (0.8 - 4.2 x 10 to the 31st erg/s. The mean value of the ratio of X-ray luminosity to bolometric luminosity for nine beta Cephei stars is found to be 8.6 x 10 to the -8th. No dependence of LX or bolometric luminosity is found on the binary or short pulsation periods of the stars, and no correlation was found between LX and the rotation velocity of the stars. It is concluded that the X-ray characteristics of the beta Cephei stars are indistinguishable from other B stars of similar luminosity. An indication was found of X-ray variations by a factor of about 2 on a time scale of about 10 min from Beta CMa.

Agrawal, P. C.↗

E2003 + 225 - A 3h 42m AM Herculis type binary system

The bright soft X-ray source E2003 + 225, originally discovered by the HEAO 1 low-energy detectors, has been found to be a new AM Herculis type binary. The optical counterpart shows a rich emission spectrum of He II, He I, and H as well as circular and linear polarization. Larger polarization in the near-infrared than in the ultraviolet argues for its origin as high harmonic cyclotron emission. Optical photometry, polarimetry, spectroscopy, and the X-ray light curves are all consistent with an orbital period of 222.51 m, the longest period known for AM Herculis systems, and only the second on the long side of the 2-3 hour cataclysmic variable period gap.

Takalo, L. O.↗

Normal incidence multilayer mirrors for extreme ultraviolet astronomy

Sputtered multilayer coatings allow the use of normal incidence optics in the extreme ultraviolet (EUV) region below 500 A. Multilayer mirrors can be tailored to provide images at strong EUV lines in the sun and stars, in many cases making more efficient use of the telescope aperture than grazing incidence optics. Alternatively, the bandpass can be broadened at the expense of peak effective area, by varying the multilayer structure over the mirror surface. Such mirrors can also serve as optical elements in spectrographs for investigation of specific emission and absorption line complexes, and are self-filtering in that they reject nearby geocoronal and cosmic resonance line backgrounds. Current efforts at the Lockheed Palo Alto Research Laboratory in the design, fabrication, and testing of EUV multilayer mirrors are discussed. This program includes the design and fabrication of normal incidence EUV multilayer mirrors, and the deposition of multilayers on lacquer-coated substrates.

Stern, R. A.↗

Rapid rotation and stellar activity in the triple system HD 165590

X-ray and ultraviolet observations of the spectroscopic and visual binary HD 165590 are presented. Results show that the spectroscopic binary component has a period of 0.88 day and a near-solar spectral type. A substantial soft X-ray flux for HD 165590 is also found with an X-ray luminosity of 10 to the 30.6th ergs/sec for the system. No obvious periodicities of less than 0.5 days are detected in the X-ray data, although stochastic variability is present. Observations of the transition region emission lines using the International Ultraviolet Explorer satellites are shown to be consistent with the X-ray data and reveal an approximately 50% variability on the time scale of days. It is concluded that comparisons of the results for HD 165590 with X-ray observations of other late F and G stars demonstrate that rotation-activity scaling relations are useful as gross predictors of X-ray emission.

Stern, R. A.↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗