Engineering topics
Stenger, Michael
Publications and source records attributed to Stenger, Michael.
Spaceflight Standard Measures
The main goal is to ensure that a minimal set of measures is consistently captured from all ISS crewmembers until the end of ISS to characterize the effects of space. The data from these measures will placed in an archive managed by HRP and can be made available to studies via data sharing agreements.
Cardiovascular Disease Risk in NASA Astronauts Across the Lifespan: Historical Cohort Studies
No abstract available
Evaluation of an Impedance Threshold Device as a VIIP Countermeasure
Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs and lower body negative pressure (LBNP) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.
Evaluation of an Impedance Threshold Device as a VIIP Countermeasure
Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.
Fluid Shifts
NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration space flight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's pre-flight condition and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. This study has been selected for flight implementation and is one of the candidate investigations being considered for the one year mission.
Fluid Shifts Before, During and After Prolonged Space Flight and Their Association with Intracranial Pressure and Visual Impairment
Future human space travel will primarily consist of long duration missions onboard the International Space Station or exploration class missions to Mars, its moons, or nearby asteroids. Current evidence suggests that long duration missions might increase risk of permanent ocular structural and functional changes, possibly due to increased intracranial pressure resulting from a spaceflight-induced cephalad (headward) fluid shift.
Evaluation of Baroreflex Effectiveness Index during Real and Simulated Microgravity: Relation to Orthostatic Intolerance
Bed Rest and Space Flight cause a significant decrease in BEI. BR causes similar changes to BEI as SF. BEI may not correlate with subjects experiencing presyncope, but error is high and n is low. Compression Garments have the potential to restore BEI after short duration BR, but do not prevent recovery.
Functional Task Test: 2. Spaceflight-Induced Cardiovascular Change and Recovery During NASA's Functional Task Test
The overall objective of the functional task test (FTT) is to correlate spaceflight-induced physiological adaptations with changes in performance of high priority exploration mission-critical tasks. This presentation will focus on the recovery from fall/stand test (RFST), which measures the cardiovascular response to the transition from the prone posture (simulated fall) to standing in normal gravity, as well as heart rate (HR) during 11 functional tasks. As such, this test describes some aspects of spaceflight-induced cardiovascular deconditioning and the course of recovery in Space Shuttle and International Space Station (ISS) astronauts. The sensorimotor and neuromuscular components of the FTT are described in two separate abstracts: Functional Task Test 1 and 3.