Engineering Papers⌕ Search

Engineering topics

Stearns, C. A.

Publications and source records attributed to Stearns, C. A..

At least 73 records · Page 4

Enhancement of oxidative vaporization of chromium (III) oxide and chromium by oxygen atoms

Rates of oxidative vaporization of Cr2O3 were found to be markedly enhanced in the presence of O atoms. Investigations were conducted over the temperature range 470 to 1520 K. For Cr2O3 the enhancement was about 10 to the 9th power at 820 K in oxygen containing 2.5 percent atoms. Rapid oxidative vaporization of bare chromium was observed below 1070 K, the rate being about one-half that of Cr2O3. Results are interpreted in terms of thermochemical analysis.

Fryburg, G. C.↗

High-temperature mass spectrometry - Vaporization of group 4-B metal carbides

The high temperature vaporization of the metal-carbon systems TiC, ZrC, HfC, and ThC was studied by the Knudsen effusion - mass spectrometric method. For each system the metal dicarbide and tetracarbide molecular species were identified in the gas phase. Relative ion currents of the carbides and metals were measured as a function of temperature. Second- and third-law methods were used to determine enthalpies. Maximum values were established for the dissociation energies of the metal monocarbide molecules TiC, ZrC, HfC, and ThC. Thermodynamic functions used in the calculations are discussed in terms of assumed molecular structures and electronic contributions to the partition functions. The trends shown by the dissociation energies of the carbides of Group 4B are compared with those of neighboring groups and discussed in relation to the corresponding oxides and chemical bonding. The high temperature molecular beam inlet system and double focusing mass spectrometer are described.

Stearns, C. A.↗

Dissociation energies of some high temperature molecules containing aluminum

The Knudsen cell mass spectrometric method has been used to investigate the gaseous molecules Al2, AlSi,AlSiO, AlC2, Al2C2, and AlAuC2. Special attention was given to the experimental considerations and techniques needed to identify and to measure ion intensities for very low abundance molecular species. Second- and third-law procedures were used to obtain reaction enthalpies for pressure calibration independent and isomolecular exchange reactions. Dissociation energies for the molecules were derived from the measured ion intensities, free-energy functions obtained from estimated molecular constants, and auxiliary thermodynamic data. The bonding and stability of these aluminum containing molecules are compared with other similar species.

Stearns, C. A.↗

Oxidation/vaporization of silicide coated columbium base alloys

Mass spectrometric and target collection experiments were made at 1600 K to elucidate the mode of oxidative vaporization of two columbium alloys, fused-slurry-coated with a complex silicide former (Si-20Cr-Fe). At oxygen pressures up to 0.0005 torr the major vapor component detected by mass spectrometry for oxidized samples was gaseous silicon monoxide. Analysis of condensates collected at oxygen pressures of 0.1, 1.0 and 10 torr revealed that chromium-, silicon-, iron- and tungsten- containing species were the major products of vaporization. Equilibrium thermochemical diagrams were constructed for the metal-oxygen system corresponding to each constituent metal in both the coating and base alloy. The major vaporizing species are expected to be the gaseous oxides of chromium, silicon, iron and tungsten. Plots of vapor phase composition and maximum vaporization rate versus oxygen pressure were calculated for each coating constituent. The major contribution to weight loss by vaporization at oxygen pressures above 1 torr was shown to be the chromium-containing species.

Kohl, F. J.↗

Vaporization of the group IVB metal carbides

High temperature vaporization of titanium, zirconium, hafnium and thorium carbides by Knudsen effusion mass spectrometry, measuring ion intensities, formation enthalpies and dissociation energies

Kohl, F. J.↗

Apparatus for simultaneous ion counting and current recording in mass spectrometry

Ion counting system is coupled to the last dynode of an Allen-type electron multiplier on the mass analyzer of a double focusing mass spectrometer. This leaves the anode available for an electrometer, making possible simultaneous measurements. Coupling is achieved by a ferrite core transformer and associated circuitry.

Kohl, F. J.↗