Two-position wax-motor rotary actuator

Two position rotary actuator rotates shaft by precisely 180 deg and rotates it back on command. Mechanism consumes 11 watts of power and functions over wide range of temperatures under high vacuum for long unattended periods. Light weight device may be used to flip magnetometer for calibration in magnetic field.

Stange, W. C.

Actuator mechanism

An actuator mechanism is described, having a frame with a rotatable shaft supported in the frame, a positioning mechanism coupled to the shaft for rotating the shaft in two rotary positions, disposed approximately 180 degrees apart, and a pair of plungers coupled to the shaft. Each plunger is responsive to a control signal for applying bi-directional rotation to the shaft.

Stange, W. C.

The MJS-77 magnetometer actuator

A two-position (0 deg and 180 deg) actuating mechanism (flipper) driven by alternately-heated wax motors (pellets) will be used to rotate the low field triaxial fluxgate magnetometer experiment on the 1977 Mariner Jupiter-Saturn spacecraft to its 0 deg and 180 deg positions. The magnetic field, power requirements, weight and volume of this device are very restrictive. The problems encountered in design and development of this mechanism are presented.

Stange, W. C.

The MJS-77 magnetometer actuator

A two-position (0 deg and 180 deg) actuating mechanism (flipper) driven by alternately-heated wax motors (pellets) used to rotate the low field triaxial fluxgate magnetometer experiment on the 1977 Mariner Jupiter-Saturn spacecraft to its 0 deg and 180 deg positions is described. The magnetic field, power requirements, weight and volume of this device are discussed. The problems encountered in design and development of this mechanism are presented.

Stange, W. C.

Cyclical bi-directional rotary actuator

A thermally powered rotary actuator is disclosed which is used for positioning a shaft in first and second positions which are disposed 180 deg apart. A pair of heat extensible springs are attached to the shaft and to the frame of the rotary actuator for selectively rotating the shaft from one of its two positions to the other position upon the application of heat to one of the heat extensible springs. The heat extensible springs are preferably constructed from the alloy 55-Nitinol. In the preferred embodiment, a detent mechanism is provided for locking the rotatable shaft in its two rotary positions.

Stange, W. C.

Cyclical biodirectional rotary actuator

Thermally powered device flips magnetometer between one of two positions located 180 deg apart and permits instrument calibration. Pair of heat-extensible springs selectively rotate shaft from one position to other when electric heaters bonded to them are energized.

Stange, W. C.

A new concept for actuating space mechanisms

A two position (0 and 180 deg) actuating mechanism driven by two alternately heated opposing flat NITINOL springs is proposed for rotating the low field triaxial fluxgate magnetometer experiment on the 1977 Mariner Jupiter-Saturn spacecraft to its 0 deg and 180 deg positions. The magnetic field, power requirements, weight, and volume of this device are very restrictive. The problems encountered in design and development are presented.