Planning and Conducting Experiments at the FAST Linac and IOTA Ring
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Stancari, Giulio.
Explore the source record for details and available documents.
Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.
High-resolution observations of single-particle dynamics have potential as a powerful tool in the diagnostics, tuning and design of storage rings. We are presenting the results of experiments with single electrons that were conducted at Fermilab’s IOTA ring to explore the feasibility of this approach. A set of sensitive, high-resolution digital cameras was used to detect the synchrotron radiation emitted by an electron, and the resulting images were used to reconstruct the time evolution of oscillation amplitudes in all three degrees of freedom. From the evolution of the oscillation amplitudes, we deduce transverse emittances, momentum spread, damping times, beam energy and estimated residual-gas density and composition. To our knowledge, this is the first time that the dynamics of a single particle in a storage ring has been tracked in all three dimensions. We discuss farther development of a single particle diagnostics that may allow reconstruction of its turn-by-turn coordinates over macroscopic periods of time facilitating ultra-precise lattice diagnostics and direct benchmarking of tracking codes.
This paper covers the progress made so far in designing the first McMillan electron lens for the Fermilab IOTA ring. The novel design allows for an increase in tune spread without limiting the dynamic aperture due to its integrability. Shown are simulations for an electron gun design to generate the specific required current density distribution for the nonlinear integrable system in IOTA.
An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.
Explore the source record for details and available documents.
As previously stated in the experiment proposal [1], the goal of the URSSE experiment was to study statistical properties of the undulator radiation generated by a single electron, circulating inthe IOTA storage ring. Namely, the idea was to study the distribution of the number of photons detected in a certain time window, and the distribution of the inter-arrival times of the photons. We wanted to see if the photostatistics was exactly Poissonian, as predicted or if there was some deviation towards Sub-Poissonian light, similar to what was observed in another study.
Quantitative theoretical model for the experiment from was developed and verified in an independent experiment in IOTA. It helped corroborate a model of intrabeam scattering in IOTA. The agreement is expected to improve in the future. It was shown that along with measurements of longitudinal bunch size the fluctuations can be used to measure transverse bunch size in some cases (e.g., in IOTA). Improvements as compared to the similar experiment: Better precision due to using the comb filter with one-turn delay and the special noise subtraction algorithm. In IOTA, fluctuations were two orders of magnitude smaller. Fluctuations data were collected for different values of bunch charge. The transition from Poisson statistics to Super-Poisson statistics was observed in undulator radiation for the first time.
We study turn-by-turn fluctuations in the number of emitted photons in an undulator, installed in the IOTA electron storage ring at Fermilab with an InGaAs PIN photodiode and an integrating circuit. Our study was motivated by the previous experiment *. We propose a theoretical model for the experimental data from * and in our own experiment we attempted to verify the model in an independent and more systematic way. Moreover, these fluctuations are an interesting subject for a study by itself, since they act as a seed for SASE in FELs. We improve the precision of the measurements from * by subtracting the average signal amplitude using a comb filter with a one-turn IOTA delay, and by using a special algorithm for noise subtraction. We obtain a reasonable agreement between our theoretical model and experiment. Along with repeating the experiment from *, which was performed at a constant beam current, we also collect data for fluctuations in undulator light at different beam current values. Lastly, in our experiment we were able to see the transition from Poisson statistics to Super-Poisson statistics for undulator light, whereas in * only the latter statistics was observed.
A single electron orbiting around a ring and emitting single quanta at the rate of about one event per hundred turns could produce a wealth of information about physical processes in large traps (i.e. storage rings) for charged particles. It should be noted that Paul and Penning traps in the 1980s led to the Nobel prize for studying state and motion of single quantum particles, and just recently the Penning trap technique has enabled the measurement of a single proton magnetic moment with an unprecedented precision of 10 decimal places. The information from the storage ring traps could also be used for characterization of a quantum system as well as the "trap" itself, i.e. measuring properties of the storage ring lattice and electron interaction with the laser fields. Although, the interest in single electron quantum processes today is mostly academic in nature, the diagnostics and methodology developed for single electron radiation studies could find subsequent applications in a variety of applied disciplines in quantum technology, including quantum communications and quantum computing.
The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. A key part of its beam diagnostics suite are synchrotron radiation monitors, used for measuring transverse beam profile, position, and intensity. In this paper, we report on the performance and uses of this system during the year 1 run. We demonstrate sub-100nm statistical beam position uncertainty and high dynamic range from 10⁹ electrons down to a single electron. Commissioning challenges and operational issues are discussed. We conclude by outlining current upgrade efforts, including improved modularity, small emittance measurements, and a multi-anode photomultiplier system for turn-by-turn acquisition.
A test stand is under construction at CERN to study high perveance electron guns, electron beam dynamics, and electron beam diagnostics for electron lenses. It will be used to test electron guns for the Hollow Electron Lenses under consideration for beam halo control for High Luminosity LHC (CERN), and for the Space Charge Compensation at SIS18 (GSI) in the frame of the EU funded ARIES project. In order to prepare for this test stand, simulations will be presented and compared with experiments undertaken at the Fermilab (FNAL) electron lens test stand. These were conducted using a hollow electron gun, with the magnetic field configuration and beam current varied to study their effect. The impact of imperfections on the beam dynamics and overall quality of the electron beam will be discussed. A method for comparing experimental data with simulation is also presented to allow bench-marking of the computer models and simulation tools that will later be applied to the analysis of measurements performed at CERN.
Detect synchrotron-light signal and characterize backgrounds in IOTA for 1) Beam diagnostics: turn-by-turn intensity monitor with wide dynamic range, from nominal intensities (~10 9 particles) down to single electrons; 2) Scientific experiments in IOTA: what is the time structure of radiation emission from a single electron in a storage ring? Is it random, regular, chaotic? Is there correlation between the emission from different dipoles?
Beam loss due to space charge is a major problem at current and future high intensity particle accelerators. The space charge force can be compensated for proton or ion beams by creating a column of electrons with a charge distribution matched to that of the beam, maintaining electron-proton stability. The column is created by the beam ionizing short sections of high pressure gas. The ionization electrons are then shaped appropriately using electric and magnetic fields. The Integrable Optics Test Accelerator (IOTA) at Fermilab is a test bed for beam loss and instability mitigation techniques. Simulations using the particle-in-cell code, Warp, have been made to track the evolution of both the electron column and the beam over multiple passes. A 2.5 MeV proton beamline is under construction at IOTA, to be used to study the effect of the electron column on a space charge dominated beam.
We report results of the beam commissioning and first operation of the 1.3 GHz superconducting RF electron linear accelerator at Fermilab Accelerator Science and Technology (FAST) facility. Construction of the linac was completed and the machine was commissioned with beam in 2017. The maximum total beam energy of about 300 MeV was achieved with the record energy gain of 250 MeV in the ILC-type SRF cryomodule. The pho-toinjector was tuned to produce trains of 200 pC bunches with a frequency of 3 MHz at a repetition rate of 1 Hz. This report describes the aspects of machine commission-ing such as tuning of the SRF cryomodule and beam optics optimization. We also present highlights of an experimental program carried out parasitically during the two-month run, including studies of wake-fields, and advanced beam phase space manipulation.
Future high current proton accelerators will need to minimize beam loss due to space-charge in order to achieve safe operation while achieving the desired physics goals. One method of space-charge compensation to be tested at the Integrable Optics Test Accelerator (IOTA) at Fermilab is the Electron Column. The concept for this device is to allow a circulating beam to ionize a small region of relatively high pressure residual gas, while using electric and magnetic fields to confine and shape the resulting plasma electrons. If the profile of the electrons is matched to the beam profile transversely and longitudinally, the electrons should counteract the space-charge force of the proton beam. Simulations of the IOTA proton beam circulating through the Electron Column have been performed, with the evolution of the electron plasma and its effect on the beam studied.
We present an overview of current applications of electron lenses to the fields of nonlinear beam dynamics and of active beam halo control.
We outline the design of beam experiments for the electron linac at the Fermilab Accelerator Science and Technology (FAST) facility and for the Integrable Optics Test Accelerator (IOTA), based on synchrotron light emitted by the electrons in bend dipoles, detected with gated microchannel-plate photomultipliers (MCP-PMTs). The system can be used both for beam diagnostics (e.g., beam intensity with full dynamic range, turn-by-turn beam vibrations, etc.) and for scientific experiments, such as the direct observation of the time structure of the radiation emitted by single electrons in a storage ring. The similarity between photon pulses and spectrum at the downstream end of the electron linac and in the IOTA ring allows one to test the apparatus during commissioning of the linac.