State-of-the-art and evolution of UFSD sensors design at FBK

Over the past few years, there has been growing interest in the development of silicon sensors able to simultaneously measure accurately the time of passage and the position of impinging charged particles. In this contribution, a review of the progresses in the design of UFSD (Ultra-Fast Silicon Detectors) sensors, manufactured at the FBK (Fondazione Bruno Kessler) Foundry, aiming at tracking charged particles in 4 dimensions, is presented. The state-of-the-art UFSD sensors, with excellent timing capability, are planned to be used in both ATLAS and CMS experiments detector upgrade, in order to reduce the background due to the presence of overlapping events in the same bunch crossing. The latest results on sensors characterization including time resolution, radiation resistance and uniformity of the response are here summarized, pointing out the interplay between the design of the gain layer and the UFSD performances. The research is now focusing on the maximization of the sensor fill factor, to be able to reduce the pixel size, exploring the implementation of shallow trenches for the pixel isolation and the development of resistive AC-coupled UFSD sensors. In conclusion, a brief review on research paths tailored for detection of low energy X-rays or for low material budget applications is given.

47 OTHER INSTRUMENTATION↗

Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm 2

In this article we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15 and 6e15 neq/cm 2 . The UFSD used in this study are circular 50 μm thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. Hamamatsu Photonics (HPK), Japan, produced the UFSD with pre-irradiation internal gain in the range 5–70 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90 Sr β-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20 °C and -30 °C. The timing resolution of each device under test was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction discriminator (CFD) method for both. The dependence of the gain upon the irradiation fluence is consistent with the acceptor removal mechanism; at -20 °C the highest gain decreases from 70 before radiation to 2 after a fluence of 6e15 n/cm 2 . Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained varying with fluence the CFD value used to determine the time of arrival, from 0.1 for pre-irradiated sensors to 0.6 at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) the contribution of charge multiplication not limited to the gain layer zone, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and were found to be in agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing layers, 4- and 5-dimension tracking

The combination of precision space and time information in particle tracking, the so called 4D tracking, is being considered in the upgrade of the ATLAS, CMS and LHCb experiments at the High-Luminosity LHC, set to start data taking in 2024–2025. Regardless of the type of solution chosen, space–time tracking brings benefits to the performance of the detectors by reducing the background and sharpening the resolution; it improves tracking performances and simplifies tracks combinatorics. Space–time tracking also allows investigating new physics channels, for example it opens up the possibilities of new searches in long-living particles by measuring accurately the time of flight between the production and the decay vertexes. The foreseen applications of 4D tracking in experiments with very high acquisition rates, for example at HL-LHC, add one more dimension to the problem, increasing dramatically the complexity of the read-out system and that of the whole detector design: we call 5D tracking the application of 4D tracking in high rate environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗