Disturbance amplification rates

Program computes incompressible linear stability characteristics for swept and tapered wings. Amplification rates of boundary-layer disturbances also are calculated. Program is useful in designing tapered, laminar-flow control wings incorporating suction to prevent boundary layer separation. Program is written in FORTRAN IV and Assembler for batch execution on CYBER 70-series.

Srokowski, A. J.↗

Development of advanced stability theory suction prediction techniques for laminar flow control

The problem of obtaining accurate estimates of suction requirements on swept laminar flow control wings was discussed. A fast accurate computer code developed to predict suction requirements by integrating disturbance amplification rates was described. Assumptions and approximations used in the present computer code are examined in light of flow conditions on the swept wing which may limit their validity.

Srokowski, A. J.↗

Cooling effectiveness of slot injection into a turbulent boundary layer

The cooling effectiveness of injection through multiple flush slots at an angle of 10 deg was studied experimentally in a wind tunnel. Air was injected from one to four slots into a turbulent Mach 6 boundary layer. The slot mass flow ratio is defined, and data which describe the dependence of the cooling effectiveness on the slot mass flow ratio are presented. Experimental values are indicated graphically for various cases of single and multiple slot injection, where the total mass injection (i.e., the sum of flow rates from each slot) is the same for each case. The results show that, for a given coolant mass flow rate, thermal protection over the maximum surface area can be accomplished best by injecting the coolant flow through multiple slots.

Howard, F. G.↗

Mass flow requirements for LFC wing design

The problem of determining optimum suction mass flow requirements for LFC wings is addressed. Some previous methods for predicting the extent of laminar flow over swept wings with suction are briefly reviewed. These range from the purely empirical to those utilizing tabulated linear stability computations. The present method is described. This method solves the linear, incompressible stability equations by spectral techniques. The maximum temporal amplification of boundary layer crossflow and 2-D disturbances is determined for waves of a given frequency. Group velocities are used to integrate these amplification rates along the wing to yield the logarithmic amplitude ratio or 'N factor' of the disturbance. The 'N factor' calibration of a computer code utilizing this method is described, using experimentally determined transition data. The method is shown to be as consistent as previously used 'fixed wavelength' methods.

Srokowski, A. J.↗

Direct measurements at Mach 6 of turbulent skin-friction reduction by injection from single and multiple flush slots

The surface skin-friction reduction downstream of one to four successive flush slots injecting at an angle of 10 deg into a turbulent Mach 6 boundary layer has been determined from direct measurements of surface shear. Increasing the number of succeeding slots increases the skin-friction reduction, but this trend reverses at high injection rates. The incremental improvement in skin-friction reduction decreases with increasing number of slots. Comparison with previously reported step slot data indicates that step slots with tangential injection are more effective in reducing skin friction than the present flush slot configuration. Finite-difference predictions are in reasonable agreement with skin-friction and boundary-layer profile data.

Srokowski, A. J.↗

Effect of slot width on transition and noise attenuation of a sound shield panel for supersonic wind tunnels

The effect of slot width on transition and noise attenuation of a planar rod wall sound shield has been investigated at Mach 6. Boundary layer laminarization was obtained by induced suction through adjustable slots or gaps between the rods. Transition Reynolds numbers increased significantly with increasing gap width. The local mean flow field above the suction panel rod array was uniform. Important factors for design and performance of a supersonic wind-tunnel sound shield are rod diameter, gap-to-rod diameter ratio, surface finish of the rods, and leading-edge configuration.

Harvey, W. D.↗

Effect of slot width on transition and noise attenuation of a flat sound shield in a Mach 6 wind tunnel

An experimental and theoretical study of a sound shield concept to attenuate the noise radiated into the test section from the turbulent boundary layer on the walls of wind tunnels was conducted. The model investigated was planar with a sharp flat plate leading edge faired into an array of rods aligned nearly parallel to the local flow. For a ratio of gap diameter to rod diameter of 0.16, the flow was laminar over the entire model at a maximum local length Reynolds number of 14 million. A 45% reduction in the tunnel free stream root mean square pressure level was measured within the shielded region for this gap width when the boundary layers on the rods were laminar. Smaller ratios of gap diameter to rod diameter resulted in substantial reductions in the transition Reynolds number, and in a 40% pressure reduction.

Stainback, P. C.↗

Multiple slot skin friction reduction

The paper investigates analytically the effect of multiple slot injection on skin friction for a representative fuselage shape (ogive-cylinder body) and evaluates the potential of slot injection as a drag reduction system in subsonic flow. Typical CTOL cruise flight conditions (Mach number equals 0.82 at altitudes of 11 km) were adopted for a fuselage 67.06 m in length and with maximum diameter of 7.32 m. The numerical method of Price and Harris (1972) was used to calculate the boundary-layer characteristics up to the first slot, while the finite-difference method of Beckwith and Bushnell (1971) was used to calculate the velocity profile downstream of one, three, five, or ten slots. An integral expression is proposed for characterizing skin friction reduction effectiveness, and it is seen that large reductions in viscous drag (50%) are available through slot injection. Skin friction reduction is improved by increasing the number of injection slots but at a diminishing rate.

Howard, F. G.↗