Engineering Papers⌕ Search

Engineering topics

Spiller, E.

Publications and source records attributed to Spiller, E..

Obtaining high resolution XUV coronal images

Photographs obtained during three flights of an 11 inch diameter normal incident soft X-ray (wavelength 63.5 A) telescope are analyzed and the data are compared to the results expected from tests of the mirror surfaces. Multilayer coated X ray telescopes have the potential for 0.01 arcsec resolution, and there is optimism that such high quality mirrors can be built. Some of the factors which enter into the performance actually achieved in practice are as follows: quality of the mirror substrate, quality of the multilayer coating, and number of photons collected. Measurements of multilayer mirrors show that the actual performance achieved in the solar X-ray images demonstrates a reduction in the scattering compared to that calculated from the topography of the top surface of the multilayer. In the brief duration of a rocket flight, the resolution is also limited by counting statistics from the number of photons collected. At X-ray Ultraviolet (XUV) wavelengths from 171 to 335 A the photon flux should be greater than 10(exp 10) ph/sec, so that a resolution better than 0.1 arcsec might be achieved, if mirror quality does not provide a limit first. In a satellite, a large collecting area will be needed for the highest resolution.

Golub, L.↗

Flares observed by the normal incidence X-ray telescope on 1989 September 11

Two solar flare events have been observed in soft X-rays during a sounding-rocket flight of the Normal-Incidence X-ray Telescope payload on September 11, 1989. The flare in X-rays involves a single bright loop crossing the neutral line, and having its footpoints at the southern ends of the ribbons; this loop accounts for more than 66 percent of the emission. Within the remainder of each of the flare ribbons, a complex coronal structure is also observed to be interacting with the main flare loop. A second event, in an active region at the limb, has a strong correlation with H-alpha images obtained at the same time. This indicates the coexistence, and indeed the close proximity, of coronal and chromospheric temperature material. Interpretations of this phenomenon are discussed.

Herant, M.↗

Construction of a multilayered X-ray telescope for solar coronal studies from space

The construction and testing of soft x-ray Ritchey-Chretien aplanatic telescope which is to be flown on a NASA sounding rocket in 1986 for very high resolution studies of the solar corona are discussed. Goals include figuring, polishing and measuring the mirror surfaces to tolerances exceding the 5000 A wavelength diffraction limit while achieving a superpolished surface finish, and the development of a structural design to withstand the rigors of the launch. Multilayer coatings are used to achieve usable reflectivity in the soft X-ray regime, and the design goal is for spatial resolution of 1/4 sec. Future applications are discussed.

Golub, L.↗

Imaging performance of a normal incidence soft X-ray telescope

Measurements are presented of the imaging performance of a normal incidence spherical soft X-ray mirror at BK-alpha (67.6 A). The reflector was a 124-layer coating consisting of alternating Re-W alloy and C layers with a protective C overcoat 34 A thick deposited on a Zerodur substrate. Measurements made at an angle of 1.5 deg off axis with the prototype of the Einstein Observatory high resolution imager reveal the resolution of the mirror to be about 1 arcsec FWHM, with 50% of the reflected power within the detector field of 512 arcsec contained within a diameter of 5 arcsec. The data demonstrate the practicality and potential good performance of normal-incidence soft X-ray optics, and show that the scattering performances of such devices may be as good or better than the best grazing incidence devices.

Henry, J. P.↗