Heat-loss Characteristics of Hot-wire Anemometers at Various Densities in Transonic and Supersonic Flow
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Spangenberg, W G.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An experimental investigation at low airspeeds was made of the filling effect observed when a screen or similar resistance is placed across a diffuser. The filling effect is found to be real in that screens can prevent separation or restore separated flow in diffusers even of extreme divergence and to depend principally on screen location and pressure-drop coefficient of the screen. Results are given for three different diffusers of circular cross section with a variety of screen arrangements. Effects of single screens and multiple screens are shown. The mechanics of the filling effect is explained, and possible efficiencies are discussed. Results of arrangements of multiple screens in wide-angle diffusers are given to show a possible application to damping screens as used in wind tunnels to reduce turbulence. (author)