Engineering Papers⌕ Search

Engineering topics

Song, Z.

Publications and source records attributed to Song, Z..

Coherent Transfer of Lattice Entropy via Extreme Nonlinear Phononics in Metal Halide Perovskites

Entropy transfer in metal halide perovskites, characterized by significant lattice anharmonicity and low stiffness, underlies the remarkable properties observed in their optoelectronic applications, ranging from solar cells to lasers. The conventional view of this transfer involves stochastic processes occurring within a thermal bath of phonons, where the lattice arrangement and energy flow from higher- to lower-frequency modes. Here, we unveil a comprehensive chronological sequence detailing a conceptually distinct coherent transfer of entropy in a prototypical perovskite CH 3 NH 3 Pbl 3 . The terahertz periodic modulation imposes vibrational coherence into electronic states, leading to the emergence of mixed (vibronic) quantum beat between approximately 3 and 0.3 THz. We highlight a well-structured bidirectional time-frequency transfer of these diverse phonon modes, each developing at different times and transitioning from high to low frequencies from 3 to 0.3 THz, before reversing direction and ascending to around 0.8 THz. First-principles molecular dynamics simulations disentangle a complex web of coherent-phononic coupling pathways and identify the salient roles of the initial modes in shaping entropy evolution at later stages. Capitalizing on coherent entropy transfer and dynamic anharmonicity presents a compelling opportunity to exceed the fundamental thermodynamic (Shockley-Queisser) limit of photoconversion efficiency and to pioneer novel optoelectronic functionalities. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m$^{2}$ of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 10$^{15}$ n$_{eq}$/cm$^{2}$. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of different silicon sensor options for the upgrade of the CMS Outer Tracker

During the high-luminosity phase of the LHC (HL-LHC), planned to start in 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to 7.5×10 34 cm –2 s –1 . A total integrated luminosity of 3000 or even 4000 fb –1 is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC,with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the new tracking system will be exposed to a significantly higher radiation than the current tracker, requiring new radiation-hard sensors. CMS initiated an extensive irradiation and measurement campaign starting in 2009 to systematically compare the properties of different silicon materials and design choices for the Outer Tracker sensors. Several test structures and sensors were designed and implemented on 18 different combinations of wafer materials, thicknesses, and production technologies. The devices were electrically characterized before and after irradiation with neutrons,and with protons of different energies, with fluences corresponding to those expected at different radii of the CMS Outer Tracker after 3000 fb –1 . The tests performed include studies with β sources, lasers, and beam scans. This paper compares the performance of different options for the HL-LHC silicon sensors with a focus on silicon bulk material and thickness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Disruption prevention using rotating resonant magnetic perturbation on J-TEXT

Major plasma disruption is one of the most critical issues to be solved for tokamak fusion reactors. Experiments to prevent mode locking and subsequent disruptions have been carried out on the J-TEXT tokamak using rotating resonant magnetic perturbations (RMPs). The tearing modes, which are locked and lead to disruptions without the application of RMPs, can be accelerated by rotating RMPs to the RMP frequency. As a result, mode locking and subsequent disruptions are delayed or prevented. The effects of RMP amplitude and frequency on disruption prevention have been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent band-edge oscillations and dynamic longitudinal-optical phonon mode splitting as evidence for polarons in perovskites

The coherence of collective modes, such as phonons and polarons, and their modulation of electronic states is long sought in complex systems, which is a crosscutting issue in photovoltaics and quantum electronics. In photovoltaic cells and lasers based on metal halide perovskites, the presence of polarons, i.e., photocarriers dressed by the macroscopic motion of charged lattice, assisted by terahertz (THz) longitudinal-optical (LO) phonons, has been intensely studied yet is still debated. This may be key for explaining the remarkable properties of the perovskite materials, e.g., defect tolerance, long charge lifetimes, and diffusion lengths. In this work we use the intense single-cycle THz pulse with peak electric field up to E THz = 1000 kV/cm to drive coherent polaronic band-edge oscillations at room temperature in CH 3 NH 3 PbI 3 (MAPbI 3 ). We reveal the oscillatory behavior is dominated by a specific quantized lattice vibration mode at $ω$ LO ~ 4 THz, which is both dipole and momentum forbidden. THz-driven coherent polaron dynamics exhibits distinguishing features: room temperature coherent oscillations at ω LO longer than 1 ps in both single crystals and thin films, mode-selective modulation of different band-edge states assisted by electron-phonon interaction, and dynamic mode splitting at low temperature due to entropy and anharmonicity of organic cations. Our results demonstrate intense THz-driven coherent band-edge modulation is a powerful probe of electron-lattice coupling phenomena and polaronic quantum control in perovskites.

36 MATERIALS SCIENCE↗

The DAQ and control system for the CMS Phase-1 pixel detector upgrade

In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of the structure of the CMS inner tracking system using nuclear interactions

The structure of the CMS inner tracking system has been studied using nuclear interactions of hadrons striking its material. Data from proton-proton collisions at a center-of-mass energy of 13 TeV recorded in 2015 at the LHC are used to reconstruct millions of secondary vertices from these nuclear interactions. Precise positions of the beam pipe and the inner tracking system elements, such as the pixel detector support tube, and barrel pixel detector inner shield and support rails, are determined using these vertices. These measurements are important for detector simulations, detector upgrades, and to identify any changes in the positions of inactive elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of thermal gap conductance using the laser flash method

Thermal gap conductance refers to overall heat conductance through a gas-filled gap as interface thermal resistance between the gas and surface has to be considered. The analysis of new ATR (Advanced Test Reactor) fuel experiments requires experimental data and models for the gap conductance of the cladding/fuel capsule gap, which typically varies from 5 μm to 50 μm and is filled with He at 1-3 atm. Although past research has studied the gap conductance between UO{sub 2} fuel and Zircaloy cladding, new experiments are needed to provide the gap conductance data between HT9 and stainless steel 316, and between advanced fuels and advanced cladding in the Accident Tolerant Fuels program. In this paper, the laser flash method is modified to measure the gap conductance. The gap is formed by welding two stainless steel 316 disks with three spacers. The temperature at the rear surface, after exposure to the laser pulse at the front surface, is modeled with 1D heat transfer through three layers. The analytic solution is then fitted with the measured temperature to determine gap conductance. The sensitivity analysis based on the 1D assumption and 3D numerical simulations were performed to assess the sensitivity and uncertainty of the measurement. It is concluded the heat capacity of the gas in the gap has minimal impact on the measurement, which indicates that the thermal property determined by this method is the thermal conductance, instead of the thermal diffusivity. Convective heat loss through sidewalls under the current experimental design has insignificant influences. Heat transfer through spacers may cause up to 10% overestimation of thermal gap conductance, but the effects can be mostly eliminated by the design of grooves on samples. The result established a pathway for gap conductance determination. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron and recoil ion momentum imaging with a magneto-optically trapped target

A reaction microscope (ReMi) has been combined with a magneto-optical trap (MOT) for the kinematically complete investigation of atomic break-up processes. With the novel MOTReMi apparatus, the momentum vectors of the fragments of laser-cooled and state-prepared lithium atoms are measured in coincidence and over the full solid angle. The first successful implementation of a MOTReMi could be realized due to an optimized design of the present setup, a nonstandard operation of the MOT, and by employing a switching cycle with alternating measuring and trapping periods. The very low target temperature in the MOT (∼2 mK) allows for an excellent momentum resolution. Optical preparation of the target atoms in the excited Li 2{sup 2}P{sub 3/2} state was demonstrated providing an atomic polarization of close to 100%. While first experimental results were reported earlier, in this work, we focus on the technical description of the setup and its performance in commissioning experiments involving target ionization in 266 nm laser pulses and in collisions with projectile ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An impurity-induced gap system as a quantum data bus for quantum state transfer

We introduce a tight-binding chain with a single impurity to act as a quantum data bus for perfect quantum state transfer. Our proposal is based on the weak coupling limit of the two outermost quantum dots to the data bus, which is a gapped system induced by the impurity. By connecting two quantum dots to two sites of the data bus, the system can accomplish a high-fidelity and long-distance quantum state transfer. Numerical simulations for finite system show that the numerical and analytical results of the effective coupling strength agree well with each other. Moreover, we study the robustness of this quantum communication protocol in the presence of disorder in the couplings between the nearest-neighbor quantum dots. We find that the gap of the system plays an important role in robust quantum state transfer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of a tight-binding ring threaded by time-periodic magnetic flux

We analytically study the effects of periodically alternating magnetic fields on the dynamics of a tight-binding ring. It is shown that an arbitrary quantum state can be frozen coherently at will by the very frequent square-wave field as well as the monochromatic-wave field when the corresponding optimal amplitudes are taken. Numerical simulations show that the average fidelity depends on not only the system parameters, but also the features of the quantum state. Moreover, taking the initial zero-momentum Gaussian wave packets as examples, we show the dependence of the threshold frequency on the width of the packet for the given average fidelities. These observations provide a means to perform the quantum-state engineering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗