Engineering Papers⌕ Search

Engineering topics

Song, Youngsup

Publications and source records attributed to Song, Youngsup.

Simultaneous Heat and Electricity Storage in a Flow Battery System

This study investigates the dual-storage capability of a redox flow battery (RFB) system, enabling simultaneous storage of heat and electricity within a single platform. Through electrochemical and thermal experiments, we evaluated how heat storage affects battery performance and vice versa using a counterflow heat exchanger integrated in a conventional RFB configuration. The results show that incorporating heat storage had a minimal impact on the electrochemical charging and discharging processes. Further, the heat discharge operated independently of electrochemical storage, confirming that both functions can coexist without interference. The combined system also enhanced overall energy conversion efficiency, demonstrating its potential as an efficient solution for supplying both thermal and electrical energythe two most widely used energy forms.

Electrical energy↗

Enhanced Laplace Pressures for Functional Surfaces: Wicking, Switchability, and Selectivity

Abstract Wetting functionalities of rough surfaces are largely determined by the Laplace pressure generated across liquid–gas interfaces formed within surface structures. Typically, rough wetting surfaces create negative Laplace pressures, enabling capillary wicking, while rough non‐wetting surfaces create positive Laplace pressures, exhibiting fluid repellency. Here, with microfabricated reentrant structures, it is shown that the same surface can exhibit either a negative or positive Laplace pressure, regardless of its intrinsic wettability. This material‐independent Laplace pressure duality enables or enhances a range of wetting functionalities including wicking, switchability, and selectivity. On the same surface, capillary rise, capillary dip, and the combination of the two which leads to further enhancement of the total sustainable capillary height and Laplace pressure, the driving force for wicking is demonstrated. Further, active switching of wetting states between the hemiwicking and the repellent Cassie state on reentrant structures is shown. Moreover, with a water‐hexane mixture system, selective wetting of reentrant structures are demonstrated, that is, water can be selectively wicked or repelled in the presence of hexane, and vice versa. These functionalities are achieved, which would typically require complex chemical coatings, solely using surface structures, thus largely expanding the design space for a wide range of thermofluidic applications.

36 MATERIALS SCIENCE↗

Three‐Tier Hierarchical Structures for Extreme Pool Boiling Heat Transfer Performance

Abstract Boiling is an effective energy‐transfer process with substantial utility in energy applications. Boiling performance is described mainly by the heat‐transfer coefficient (HTC) and critical heat flux (CHF). Recent efforts for the simultaneous enhancement of HTC and CHF have been limited by an intrinsic trade‐off between them—HTC enhancement requires high nucleation‐site density, which can increase bubble coalescence resulting in limited CHF enhancement. In this work, this trade‐off is overcome by designing three‐tier hierarchical structures. The bubble coalescence is minimized to enhance the CHF by defining nucleation sites with microcavities interspersed within hemi‐wicking structures. Meanwhile, the reduced nucleation‐site density is compensated for by incorporating nanostructures that promote evaporation for HTC enhancement. The hierarchical structures demonstrate the simultaneous enhancement of HTC and CHF up to 389% and 138%, respectively, compared to a smooth surface. This extreme boiling performance can lead to significant energy savings in a variety of boiling applications.

36 MATERIALS SCIENCE↗

Alteration of pool boiling heat transfer on metallic surfaces by in situ oxidation

The critical heat flux during pool boiling has been investigated for a range of applications including electrical power generation and thermal management. Reported experimental CHF values during pool boiling of water on flat metallic surfaces, however, show a large discrepancy across studies. Here, we address this discrepancy in CHF values by accounting for oxidation of metallic surfaces during boiling. We studied the effect of in situ oxidation on flat Cu and Ni surfaces by changing the duration that samples were held in saturated water before conducting boiling experiments. The morphology and chemical composition of surfaces after the boiling experiments were analyzed by atomic force microscopy and X-ray photoelectron spectroscopy, respectively. Cu surfaces showed gradually increasing CHF values as the duration in saturated water increased, which could be attributed to the increase in roughness due to the formation of Cu 2 O nanostructures. Conversely, Ni surfaces showed relatively stable CHF and morphology as a nearly flat layer of NiO formed, with one exception: formation of a highly wetting hydroxide, Ni(OH) 2 , on a Ni coupon held in saturated water for 24 h resulted in a uniquely high CHF value, signifying the importance of surface chemistry in addition to morphology. Finally, the fundamental mechanisms resulting in the wide spread of CHF values on metallic surfaces elucidated in this work will lead to more accurate estimation of CHF as well as a deeper mechanistic understanding of CHF values on engineered surfaces.

42 ENGINEERING↗

Unified descriptor for enhanced critical heat flux during pool boiling of hemi-wicking surfaces

Boiling heat transfer is dictated by interfacial phenomena at the three-phase contact line where vapor bubbles form on the surface. Structured surfaces have shown significant enhancement in critical heat flux (CHF) during pool boiling by tailoring interfacial phenomena. This CHF enhancement has been primarily explained by two structural effects: roughness, which extends the contact line length at the bubble base, and wickability, the ability to imbibe liquid through surface structures by capillary pumping. Here, in this work, we show that CHF enhancement on structured surfaces cannot be described by roughness or wickability alone. This result was confirmed using systematically designed micropillar surfaces with controlled roughness and wickability. Further, we performed a scaling analysis and derived a unified descriptor, which represents the combined effects of thin film density and volumetric wicking rate. This unified descriptor shows a reasonable correlation with CHF values with our experiments and literature data. This work provides important insights in understanding the role of surface structures on CHF enhancement, thereby providing guidelines for the systematic design of surface structures for enhanced pool boiling heat transfer.

42 ENGINEERING↗