Engineering Papers⌕ Search

Engineering topics

Snyder, Lucas

Publications and source records attributed to Snyder, Lucas.

Templates of expected measurement uncertainties

The covariance committee of CSEWG (Cross Section Evaluation Working Group) established templates of expected measurement uncertainties for neutron-induced total, (n,γ), neutron-induced charged-particle, and (n,xn) reaction cross sections as well as prompt fission neutron spectra, average prompt and total fission neutron multiplicities, and fission yields. Templates provide a list of what uncertainty sources are expected for each measurement type and observable, and suggest typical ranges of these uncertainties and correlations based on a survey of experimental data, associated literature, and feedback from experimenters. Information needed to faithfully include the experimental data in the nuclear-data evaluation process is also provided. These templates could assist (a) experimenters and EXFOR compilers in delivering more complete uncertainties and measurement information relevant for evaluations of new experimental data, and (b) evaluators in achieving a more comprehensive uncertainty quantification for evaluation purposes. This effort might ultimately lead to more realistic evaluated covariances for nuclear-data applications. In this topical issue, we cover the templates coming out of this CSEWG effort–typically, one observable per paper. This paper here prefaces this topical issue by introducing the concept and mathematical framework of templates, discussing potential use cases, and giving an example of how they can be applied (estimating missing experimental uncertainties of 235 U(n,f) average prompt fission neutron multiplicities), and their impact on nuclear-data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

In this work, the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission TPC cross section ratio results [Abstract]

The fission TPC was designed for precision fission cross section ratio measurements. The high-fidelity 3D particle tracking data is used to conduct a detailed analysis of the uncertainty contributions. In this contribution a brief overview of the instrument was presented. The results of the 238 U(n,f)/ 235 U(n,f) cross section ratio measurement published in [Phys. Rev C 97, 034618 (2018)] were reviewed and the preliminary status of the 239 Pu(n,f)/ 235 U(n,f) cross section ratio measurement was shown.

238U(n,f)/235U(n,f) cross section ratio↗

Applying a Template of Expected Uncertainties to Updating 239 Pu(n,f) Cross-section Covariances in the Neutron Data Standards Database

Templates of uncertainties expected in specific measurement types were recently developed. One aim of these templates is to help evaluators in identifying (1) missing or suspiciously low uncertainties and (2) missing correlations between uncertainties of the same and different experiments, when estimating covariances for experimental data employed in their evaluations. These templates also provide realistic estimates of standard deviations and correlations for a particular uncertainty source and measurement type that can be used by evaluators in situations where they are not supplied by the experimenters. This information allows for a more comprehensive uncertainty analysis across all measurements considered in an evaluation and, thus, more realistic evaluated covariances. Here, in this work, we extend a template that is applicable to uncertainties expected in neutron-induced fission, (n,f), cross-section measurements. It is applied to improving covariances of 239 Pu(n,f) cross-section measurements in the database underlying the Neutron Data Standards evaluations. This particular example was chosen since this evaluation is primarily based on experimental information. Also, some uncertainties of individual 239 Pu(n,f) cross-section experiments in this database were suspected to be underestimated. The evaluated uncertainties obtained after updating the covariances in the database by means of the template indeed do increase compared to their original values. Even more importantly, the evaluated mean values change noticeably. These modified cross sections impact application calculations significantly, as is demonstrated by employing them in simulations of the effective neutron multiplication factor for a few selected critical assemblies. However, this updated evaluated 239 Pu(n,f) cross section should not be interpreted as the final one that should replace values of the current Neutron Data Standards project. Evaluations for the Neutron Data Standards of the 239 Pu(n,f) cross section must be linked to many other observables included in the associated database, most notably to cross sections for 235 U(n,f), but also to those for 10 B(n, α ), 6 Li(n,t), 238 U(n,f), and 238 U(n, γ ), because of included measurements of the 239 Pu(n,f) cross section that appear as ratios to these reactions. Some of these other reactions are correlated to further observables in the database. Hence, updating uncertainties of data sets of any of these observables can potentially impact the 239 Pu(n,f) cross section. Uncertainties for all measurements of these linked physical observables have to be updated before a comprehensive evaluation of the 239 Pu(n,f) cross section and its corresponding uncertainties can be provided.

239Pu Neutron-induced fission cross-section↗