Engineering Papers⌕ Search

Engineering topics

Smith, William

Publications and source records attributed to Smith, William.

25 records · Page 2

Applications of a Forward-Looking Interferometer for the On-board Detection of Aviation Weather Hazards

The Forward-Looking Interferometer (FLI) is a new instrument concept for obtaining measurements of potential weather hazards to alert flight crews. The FLI concept is based on high-resolution Infrared (IR) Fourier Transform Spectrometry (FTS) technologies that have been developed for satellite remote sensing, and which have also been applied to the detection of aerosols and gases for other purposes. It is being evaluated for multiple hazards including clear air turbulence (CAT), volcanic ash, wake vortices, low slant range visibility, dry wind shear, and icing, during all phases of flight. Previous sensitivity and characterization studies addressed the phenomenology that supports detection and mitigation by the FLI. Techniques for determining the range, and hence warning time, were demonstrated for several of the hazards, and a table of research instrument parameters was developed for investigating all of the hazards discussed above. This work supports the feasibility of detecting multiple hazards with an FLI multi-hazard airborne sensor, and for producing enhanced IR images in reduced visibility conditions; however, further research must be performed to develop a means to estimate the intensities of the hazards posed to an aircraft and to develop robust algorithms to relate sensor measurables to hazard levels. In addition, validation tests need to be performed with a prototype system.

West, Leanne↗

Integrated Approach to User Account Management

IT environments consist of both Windows and other platforms. Providing user account management for this model has become increasingly diffi cult. If Microsoft#s Active Directory could be enhanced to extend a W indows identity for authentication services for Unix, Linux, Java and Macintosh systems, then an integrated approach to user account manag ement could be realized.

Kesselman, Glenn↗

WSTF Pyrovalve Test Program Status: 2000

Extensive propulsion and pyrotechnic testing has been in progress at NASA/JSC White Sands Test Facility (WSTF) since 1995, starting with the Mars Observer Propulsion and Pyrotechnics Corrective Action Test Program (MOCATP). The MOCATP has been concluded, but extensive pyrovalve testing plus research and development continues at WSTF. Our capability to accurately characterize pyrovalve combustion product blow-by into propellant systems, evaluate hydrazine and monomethylhydrazine (MMH) thermal decomposition initiated by blow-by, and characterize valve actuation operation, continues to be used and refined. Data from this and several low blow-by pyrovalves manufactured by Conax and other corporations continues to be evaluated as a potential corrective measure for blow-by induced propellant explosions. Additionally, new measurement techniques are being developed, advanced pyrovalve development is under-way, and nondestructive examination (NDE) methods are being developed to help ensure pyrovalve safety. Starting in 2000 these data are being formatted into a pyrovalve application and testing handbook. Near-term testing includes evaluation of 3/8-in. Conax pyrovalves and other commercially available valves; development of advanced pyrovalve subcomponent technology; investigation of NDE techniques to evaluate pyrovalve ram seals and real-time measurement of housing deformation; and investigation of pyrotechnically induced explosive hydrazine decomposition both through testing and modeling. Evaluation of 3/8-in. Conax valves is to include operational margin testing to be accomplished at the NASA Langley Research Center.

Saulsberry, Regor L.↗

Status of WSTF Pyrovalve Handbook Development in Year 2000

Significant data have been generated through various spacecraft propulsion system projects involving the use of pyrotechnically operated valves (pyrovalves). These data need to be analyzed, interpreted, summarized, associated, and formatted so they can be made available for spacecraft propulsion system design involving pyrovalves and used to specify test procedures in the performance evaluation and qualification of these systems. To meet this need, a Pyrovalve Handbook is being developed at the NASA White Sands Test Facility. Standards of performance for pyrovalve applications are being formulated under the sponsorship of the NASA Technical Standards Program, as are pyrovalve testing standards under the sponsorship of the NASA Safety and Risk Management Program. The ultimate goal is to have the Handbook adopted as a voluntary standard under the guidance of the AIAA Energetic Components and Systems Technical Committee and, in a more restrictive format, become an integral part of ISO standards for Explosive Systems and Devices Used on Space Vehicles. Feedback from both Government and industry is encouraged and will be the focus of the presentation. It is especially critical that feedback be received on content and formatting of the Handbook to maximize benefit to the technical community. Submission of validated data from organizations outside of NASA is also encouraged.

Howard, Julien L.↗

Mars Observer Propulsion and Pyrotechnics Corrective Actions Test Program Status-1999

An extensive propulsion and pyrotechnic test program has been in progress at the NASA White Sands Test Facility since 1995. This program created the capabilities to: accurately measure and characterize pyrovalve combustion product blow-by into propellant systems; characterize valve operation using a Velocity Interferometer System for Any Reflector (VISAR); and evaluate hydrazine and monomethylhydrazine thermal decomposition initiated by blow-by. These capabilities were further utilized and refined this year. Low blow-by pyrovalves manufactured by Conax Florida Corporation continued to be evaluated as a potential corrective measure for blow-by induced propellant explosions. Development and testing of various advanced pyrovalves and investigation of explosion mechanisms also continued. Current and near-term testing includes: evaluation of 3/8 in. Conax pyrovalves and other commercially available valves; development and testing of advanced pyrovalve subcomponent technologies including a zero blow-by pyrovalve ram, composite overwrapped ram cylinder, and a zero particulate generating poppet; investigation of non-destructive evaluation techniques to evaluate pyrovalve ram seals; and testing and modeling of pyrotechnically induced explosive hydrazine decomposition. Evaluation of 3/8 in. Conax valves will include operational margin testing to be accomplished at NASA Langley Research Center. The test program also seeks to compile and format significant amounts of data from this and other pyrovalve test programs to generate a pyrovalve applications handbook. The handbook will facilitate formation of standards that ensure safe spacecraft applications. Current data and future plans are discussed, and community interaction is encouraged.

Saulsberry, Regor↗

Method and an apparatus for detecting ionizable substance

The amount of ionizable substance within a stream can be continuously monitored through the use of an ionizable substance detector. The substance is ionized at an electrode producing ions and free electrons. The ions are transported across an ion exchange membrane, while the free electrons flow through a power source. The current, produced by the electrons, is proportional to the amount of substance in the stream. Continuous monitoring can be useful in early detection of problems, or system fluctuations.

McElroy, James F.↗

Ionizable-Substance Detector

Device that includes all conventional components of fuel cell and electrolyzer continuously monitors concentration of ionizable substance in stream of fluid without significantly disrupting flow or chemical composition. Among substances monitored are hydrogen, sodium, fluorine, chlorine, oxygen, and bromine. Useful in early detection of fluctuations, malfunctions, or hazards. Particularly useful for detecting hydrogen in stream of water in closed system containing oxygen, wherein concentration of hydrogen must not exceed given maximum, lest hydrogen react explosively with oxygen. Also used to monitor exhaust stream to comply with environmental-protection requirements.

Mcelroy, William↗