Engineering Papers⌕ Search

Engineering topics

Smith, Ryan

Publications and source records attributed to Smith, Ryan.

At least 19 records

A stress-induced source of phonon bursts and quasiparticle poisoning

Abstract The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called “quasiparticle poisoning”. Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

The Toughness of Interlocking Metasurfaces

Interlocking metasurfaces (ILMs) are arrays of autogenous latching unit cells patterned across a surface. These create structural joints similar to bioinspired suture joints but patterned over a 2D surface rather than a 1D seam. This enables ILMs to be an alternative to conventional joining technologies such as bolts, welds, and adhesives. However, compared to conventional joining methods, relatively little is known of the engineering considerations for designing structural ILMs. Herein, the interfacial toughness of an archetypal ILM is examined for the first time. Under the conditions studied here, the ILM is substantially tougher than the material from which it is made, in this case, exhibiting up to a 50% increase in interfacial crack initiation energy over the solid base material, a photocured 3D‐printed polymer. Through experimental tests using in‐situ digital image correlation along with complementary computational analyses, the mechanism of toughening in the ILM structure and the origins of toughness anisotropy are revealed. The increase in toughness is associated with cross‐cell interactions, that is, load‐sharing across unit cells, which give rise to a finite process zone length with different effective material properties. In this way, ILM toughening is analogous to crack blunting in ductile materials or fiber bridging in composites; yet here, the ILM is composed of a single‐phase base material and so the architected toughening is geometric in nature and hence amenable to future topological optimization.

fracture↗

A study of Cell Cracks Formation During Freight Shipping : Monitoring Shock and Temperature in Real-Time & Assessing Damages With Pre and Post-Transit Characterizations of PV Modules

The solar photovoltaic (PV) industry often experiences module damage during transportation. PV modules stacked horizontally and strapped on wooden pallets may develop failures impacting their efficiency (glass shattering, cracks, frame indentation, etc.), especially when modules are not packed by professionals. The appearance of failures during the shipment from one laboratory to another can be detrimental to research studies. In this study, we tested a reusable plastic pallet designed to ship modules vertically. Five technologies of commercial PV modules were shipped together from Arizona to Florida including: glass/glass bifacial modules (framed and frameless), glass/transparent backsheet bifacial modules and glass/white backsheet modules (framed). Each module technology has a different physical size. Some modules had pre-existing cell-cracks allowing for the study of cell-crack formation and propagation during shipment. Dark current-voltage (I-V), light I-V and electroluminescence characterization were performed before and after shipment. A datalogger was used to monitor shocks and ambient temperature throughout the shipment and identify when the modules were more susceptible to damage. The modules were tilted upon receipt and the pallet were damaged but with no shattered modules. Time series shock data provided by the datalogger were used to determine potential responsible events. Our results reveal a few new post-transportation cracks for some modules. Modules parameters before and after shipment are also compared regarding the module constructions and their position in the pallet.

14 SOLAR ENERGY↗

Review of Potential–Induced Degradation in Bifacial Photovoltaic Modules

Bifacial modules are increasingly deployed in the field and are expected to represent half of the market share within 10 years. Their rear structure differs from monofacial modules to allow additional light absorption. However, it brings new reliability challenges to address. In particular, the risk of potential-induced degradation (PID) is increased as both module sides are impacted. Different PID processes have been identified in the literature: shunting type (PID-s), polarization type (PID-p), Na penetration type, and corrosion type (PID-c). Their occurrence depends on the photovoltaic system configuration as well as the module's materials. Apart from PID-s, PID processes are not well understood and extensive research is needed to elucidate the PID scenario and underlying mechanisms. Herein, current knowledge about PID processes and their impact on the main bifacial modules in the market are gathered with the aim to guide future research. Bifacial module technologies and leakage current paths leading to PID are described. Indoor and outdoor PID testing methods are detailed. For each bifacial module technology, the PID processes are investigated with their indicators, mechanism and recovery process. Furthermore, PID-impacting factors and limitation solutions are finally reported and a state of the art on PID modeling is presented.

14 SOLAR ENERGY↗

Accuracy of Vaisala RS41 and RS92 Upper Tropospheric Humidity Compared to Satellite Hyperspectral Infrared Measurements

Radiosondes are important for calibrating satellite sensors and assessing sounding retrievals. Vaisala RS41 radiosondes have mostly replaced RS92 in the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) and the conventional network. This study assesses RS41 and RS92 upper tropospheric humidity (UTH) accuracy by comparing with Infrared Atmospheric Sounding Interferometer (IASI) upper tropospheric water vapor absorption spectrum measurements. Using single RS41 and RS92 soundings at three GRUAN and DOE Atmospheric Radiation Measurement (ARM) sites and dual RS92/RS41 launches at three additional GRUAN sites, collocated with cloud-free IASI radiances (OBS), we compute Line-by-Line Radiative Transfer Model radiances for radiosonde profiles (CAL). We analyze OBS-CAL differences from 2015 to 2020, for daytime, nighttime, and dusk/dawn separately if data is available, for standard (STD) RS92 and RS41 processing, and RS92 GRUAN Data Processing (GDP; RS41 GDP is in development). We find that daytime RS41 (even without GDP) has ~1% smaller UTH errors than GDP RS92. RS41 may still have a dry bias of 1–1.5% for both daytime and nighttime, and a similar error for nighttime RS92 GDP, while standard RS92 may have a dry bias of 3–4%. These sonde humidity biases are probably upper limits since “cloud-free” scenes could still be cloud contaminated. Radiances computed from European Centre for Medium-Range Weather Forecasts (ECMWF) analyses match better than radiosondes with IASI measurements, perhaps because ECMWF assimilates IASI measurements. Relative differences between RS41 STD and RS92 GDP, or between radiosondes and ECMWF humidity profiles obtained from the radiance analysis, are consistent with their differences obtained directly from the RH measurements.

54 ENVIRONMENTAL SCIENCES↗

A biosorption-based approach for selective extraction of rare earth elements from coal byproducts

Coal byproducts could be a promising feedstock to alleviate the supply risk of critical rare earth elements (REEs) due to their abundance and REE content. Herein, we investigated the economic and environmental potential of producing REEs from coal fly ash and lignite through an integrated process of leaching, biosorption, and oxalic precipitation based on experimental data and modeling results. Two microbe immobilization systems (PEGDA) microbe beads and Si sol-gels) were examined for their efficiency in immobilizing Arthrobacter nicotianae to selectively recover REEs. Techno-economic analysis revealed that North Dakota lignite could be a profitable feedstock when Si sol-gel is used due to its high cell loading and REE adsorption capacity. Life cycle analysis revealed that Si sol-gel based biosorption could be more environmental friendly than the prevailing REE production in China due to use of less toxic chemicals. However, fly ash sourced from Powder River Basin coals was neither profitable or environmentally sustainable, primarily due to low solublity of high-value scandium at an economical pulp density (100 ash/L). To further improve the proposed biotechnology, future research could focus on scandium recovery, leaching efficiency, and microbe carriers.

20 FOSSIL-FUELED POWER PLANTS↗

Prediction of Potential-Induced Degradation Rate of Thin-Film Modules in the Field Based on Coulombs Transferred

We validated the use of coulombs transferred between the active cell circuit and ground as an index for quantitatively predicting degradation rate in the field for two thin-film module types undergoing potential-induced degradation (PID). The dependence was determined by comparing the degradation rate and leakage current in the field (Cocoa, Florida) to accelerated tests (85 degrees C, 85% relative humidity), both with the application of -1,000 V bias to the cell circuit. The two module types, which degraded about 4% and 11% in power after application of 96 h of bias in chamber, degraded 5% in the field by PID within 200 days and 6 days, respectively. The signatures of PID in the thin-film modules by electroluminescence, photoluminescence, and thermography are shown so that PID in fielded thin-film modules can be identified.

14 SOLAR ENERGY↗

Overpumping leads to California groundwater arsenic threat

Water resources are being challenged to meet domestic, agricultural, and industrial needs. To complement finite surface water supplies that are being stressed by changes in precipitation and increased demand, groundwater is increasingly being used. Sustaining groundwater use requires considering both water quantity and quality. A unique challenge for groundwater use, as compared with surface water, is the presence of naturally occurring contaminants within aquifer sediments, which can enter the water supply. Here we find that recent groundwater pumping, observed through land subsidence, results in an increase in aquifer arsenic concentrations in the San Joaquin Valley of California. By comparison, historic groundwater pumping shows no link to current groundwater arsenic concentrations. Our results support the premise that arsenic can reside within pore water of clay strata within aquifers and is released due to overpumping. We provide a quantitative model for using subsidence as an indicator of arsenic concentrations correlated with groundwater pumping.

54 ENVIRONMENTAL SCIENCES↗

Development of a gall-resistant stainless-steel hardfacing alloy

Here, this work details the development of a new cobalt-free stainless steel powder metallurgy hardfacing alloy designed to replace Stellite 6, a cobalt-based hardfacing alloy used in nuclear valve applications. The fundamental strategy centers on alloying stainless steels with up to 0.5 wt% nitrogen, which is shown to increase both the volume fraction of hard phase precipitates and the strain-hardening rate of the matrix. The resultant alloy, Nitromaxx, exhibits galling performance that is comparable to Stellite 6, up to 350 °C. This performance is attributed to the suppression of strain localization events associated with galling. In particular, transmission electron microscopy and diffraction measurements from tensile tests show that the nitrogen addition decreases the calculated matrix stacking fault energy and enhances both deformation-induced martensite transformation at room temperature and deformation twinning at elevated temperature. These strain-hardening mechanisms, coupled with the increase in precipitate volume fraction, effectively suppress localization and enhance galling resistance up to 350 °C. Lastly, the enhanced galling resistance cannot be rationalized in terms of tensile stress-strain response alone.

36 MATERIALS SCIENCE↗

Liquefaction of Forest Biomass to "Drop-in" Hydrocarbon Biofuels

The overall goal of the project was to demonstrate solvent liquefaction as a viable path to stable intermediates for subsequent upgrading to fuel blendstocks. Iowa State University (ISU) utilized technology developed by Chevron to produce “green crude” via continuous biomass liquefaction to bio-oil without catalyst or reducing gas, then upgraded the crude to drop-in hydrocarbon liquid transportation fuels. Original benchmarks for the project included conversion of biomass to bio-oil at a yield of 50% or more, produce bio-oil with oxygen content below 20 wt%, and recycle a portion of the bio-oil product for use as solvent, displacing initial hydrocarbon solvent. Initial testing and technology development was completed by Chevron using a custom Small Continuous Liquefaction Unit (SCLU) operated in “once-through” mode. In this system, liquid product and solid residual/char was collected together and required both off-line solids removal and product separation. This unit was disassembled and major components incorporated into a redesigned solvent liquefaction system at ISU capable of processing biomass at rates up to 1 kg/h. Online, continuous solids separation and bio-oil recovery/separation systems were successfully implemented. Online solids removal using an acetone injection to aid in separation achieved over 99% solids removal efficiency, and acetone recovery of greater than 97% was achieved. The gas stripping system developed for the separation of medium wood oil (MWO) for the recycle stream from the heavy wood oil (HWO) product stream was also successful in recovering approximately 93 wt% of the initial solvent from the biomass-derived products. Due to the generation of fine particulate and the high molecular weight of the HWO which both negatively affect the ability to separate the product oil, solvent recycle was not fully implemented in the system. The biomass used in this project is loblolly pine forest residue. The solvent was a blend of two hydrocarbon liquids. The majority of the solvent was comprised of commercially available naphthalene-depleted heavy aromatic solvent. The hydrogen donor solvent was a proprietary cut of light cycle oil (LCO) that was hydrotreated. As much as 25 wt% of the solvent mixture was comprised of the hydrotreated LCO. Higher blend ratios were limited by the economics of providing hydrogen to the process in this manner. Two cases were evaluated for technical feasibility on the SCLU. These are 1. Simulated phenolic solvent recycle and 2. Hydrocarbon-rich solvent processing. The simulated phenolic solvent recycle case was based on an idealistic solvent mixture where only 5% makeup or hydrogen donor solvent entered the system. The resulting solvent mixture at steady state was estimated to be 75 wt% depleted hydrogen donor, 20 wt% biomass derived phenolic monomers, and 5 wt% HLCO. This case resulted in the highest bio-oil organic yield observed in the project of 66.7 wt% on a solvent-less, dry biomass basis and relatively low oxygen content of 12%. Additionally, these conditions deconstructed the biomass so well, that extremely fine particulate was generated such that 5 micron barrier filters were unable to remove the material. Offline addition of acetone, centrifugation and acetone removal were required in order to remove the particulate prior to fractionation with the stripping column. The resulting HWO had a high molecular weight and was therefore very viscous in nature, remaining solid at room temperature. Additionally, the column was unable to sustainably strip enough MWO to close the recycle loop balance while maintaining flowability of product oil exiting the column. It was determined that additional HLCO would be required at the front of the process to decrease product viscosity both by dilution and additional hydrogen transfer into the HWO product oil. The hydrocarbon rich mixture was the preferred mixture for a majority of the project and featured a 25% donor or HLCO content and 75% depleted hydrogen donor mix. A series of three tests were conducted using this mixture and serve as the basis for a paper detailing the system. While the online acetone injection system for high pressure solids removal was demonstrated early on using this mixture, difficulty controlling process flows led to the use of an atmospheric stirred tank filtration system. At these high donor solvent levels, the product stream easily partitioned with sufficient MWO to close the recycle loop balance. Additionally, this mixture produced HWO product oil at just over 55% yield, <5% oxygen content, and a reasonable viscosity at room temperature. A 56 hour campaign was conducted with the ISU pilot to produce a large enough batch of HWO product oil to conduct upgrading experiments at Chevron’s Richmond, CA facility. Benchtop hydrotreating units were used to conduct long-duration hydrogenation/hydrogenolysis reactions in order to provide yield data and help validate assumptions made in the TEA model. Resulting products featured an oxygen content of <1%, near the detectability limit. Hydrocracking simulations were also performed, and a distribution of heavy wood oil to refinery products was determined. These distributions are based on a database of commercial and pilot plant operation used by Chevron to estimate product yield from novel inputs based on the input physical and chemical characteristics. While multi-week benchtop hydrotreating tests were successfully conducted without fouling, analysis and testing of the heavy wood oil suggest it may be better suited for hydrocracking. Metals content in the heavy wood oil would likely create catalyst fouling over time and reduce lifetime of hydrotreating catalysts. Yields and product partitioning were also more favorable from hydrocracking compared to those from hydrotreating.

09 BIOMASS FUELS↗

Modeling Current Transfer from PV Modules Based on Meteorological Data

Current transferred from the active cell circuit to ground in modules undergoing potential-induced degradation (PID) stress is analyzed with respect to meteorological data. Duration and coulombs transferred as a function of whether the module is wet (from dew or rain) or the extent of uncondensed surface humidity are quantified based on meteorological indicators. With this, functions predicting the mode and rate of coulomb transfer are developed for use in estimating the relative PID stress associated with temperature, moisture, and system voltage in any climate. Current transfer in a framed crystalline silicon module is relatively high when there is no condensed water on the module, whereas current transfer in a thin-film module held by edge clips is not, and displays a greater fraction of coulombs transferred when wet compared to the framed module in the natural environment.

14 SOLAR ENERGY↗

Solar variability datalogger

To address the lack of knowledge of local solar variability, we have developed and deployed a low-cost solar variability datalogger (SVD). While most currently used solar irradiance sensors are expensive pyranometers with high accuracy (relevant for annual energy estimates), low-cost sensors display similar precision (relevant for solar variability) as high-cost pyranometers, even if they are not as accurate. In this work, we present evaluation of various low-cost irradiance sensor types, describe the SVD, and present validation and comparison of the SVD collected data. In conclusion, the low cost and ease of use of the SVD will enable a greater understanding of local solar variability, which will reduce developer and utility uncertainty about the impact of solar photovoltaic (PV) installations and thus will encourage greater penetrations of solar energy.

14 SOLAR ENERGY↗

Constitutive Models for the Viscoelastic Behavior of Polyimide Membranes at Room and Deep Cryogenic Temperatures

Targets for ICF shots on NIF typically use ~500nm thin polyimide films with a coating of 25nm of aluminum as windows that seal the laser entrance hole or LEH. Their role is to contain the hohlraum gas and minimize the extraneous infra-red radiation getting in. This is necessary to precisely control the hohlraum thermal environment for layering inside the capsule with solid deuterium-tritium at 18K. Here, we use our empirical data on the bulging behavior of these foils under various different conditions to develop models to capture the complex viscoelastic behavior of these films at both ambient and cryogenic temperatures. The constitutive equations derived from these models give us the ability to quantitatively specify the film’s behavior during the fielding of these targets and set the best parameters for new target designs.

36 MATERIALS SCIENCE↗