Engineering Papers⌕ Search

Engineering topics

Smith, John R.

Publications and source records attributed to Smith, John R..

At least 19 records

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗

Cygnus Performance on Vega

The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2, each with the following specifications: 4-Rad dose at 1 m, 1-mm spot size, 50-ns pulse length, and 2.25-MeV endpoint energy. Cygnus 1 and 2 have been used for radiography of subcritical experiments at the Nevada National Security Site (NNSS) since 2004. The Cygnus Facility is located in an underground tunnel complex named U1a. The Cygnus sources were developed as a primary diagnostic for these experiments. The first subcritical experiment to utilize Cygnus, Armando, was executed on May 25, 2004. Since Armando, several other subcritical experiments have been executed in front of Cygnus, as well as physics experiments and plutonium calibration tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cygnus Dual Beam Radiographic Facility Refurbishment completed at U1A tunnel in Nevada NNSS meeting Level 2 milestone (P-23 Highlights 6/10/12)

A moratorium was placed on U.S. underground nuclear testing in 1992. In response, the Stockpile Stewardship Program was created to maintain readiness of the existing nuclear inventory through several efforts such as computer modeling, material analysis, and subcritical nuclear experiments (SCEs). As in the underground test era, the Nevada National Security Site (NNSS), formerly the Nevada Test Site, provides a safe and secure environment for SCEs by the nature of its isolated and secure facilities. A major tool for SCE diagnosis installed in the 05 drift laboratory is a high energy x-ray source used for time resolved imaging. This tool consists of two identical sources (Cygnus 1 and Cygnus 2) and is called the Cygnus Dual Beam Radiographic Facility (Figs. 2-6). Each Cygnus machine has 5 major elements: Marx Generator, Pulse Forming Line (PFL), Coaxial Transmission Line (CTL), 3-cell Inductive Voltage Adder (IVA), and Rod Pinch Diode. Each machine is independently triggered and may be fired in separate tests (staggered mode), or in a single test where there is submicrosecond separation between the pulses (dual mode). Cygnus must operate as a single shot machine since on each pulse the diode electrodes are destroyed. The diode is vented to atmosphere, cleaned, and new electrodes are inserted for each shot. There is normally two shots per day on each machine. Since its installation in 2003, Cygnus has participated in: 4 Subcritical Experiments (Armando, Bacchus, Barolo A, and Barolo B), a 12 shot plutonium physics series (Thermos), and 2 plutonium step wedge calibration series (2005, 2011), resulting in well over 1000 shots. Currently the Facility is in preparation for 2 SCEs scheduled for this calendar year - Castor and Pollux. Cygnus has performed well during 8 years of operations at NNSS. Many improvements in operations and performance have been implemented during this time. Throughout its service at U1a, major maintenance and replacement of many hardware items were delayed due to programmatic requirements. It is anticipated that Cygnus will be in service at U1a for another 5 years. With this assumption, it was realized that significant resources and effort should be allotted to bring the hardware back to its original condition, or even to improve elements when appropriate. The Cygnus Refurbishment and Enhancement Project started in April, 2011 with the intent to encompass a major overhaul of Cygnus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods and apparatus for constructing and implementing a universal extension module for processing objects in a database

Methods and apparatus for providing a multi-tier object-relational database architecture are disclosed. In one illustrative embodiment of the present invention, a multi-tier database architecture comprises an object-relational database engine as a top tier, one or more domain-specific extension modules as a bottom tier, and one or more universal extension modules as a middle tier. The individual extension modules of the bottom tier operationally connect with the one or more universal extension modules which, themselves, operationally connect with the database engine. The domain-specific extension modules preferably provide such functions as search, index, and retrieval services of images, video, audio, time series, web pages, text, XML, spatial data, etc. The domain-specific extension modules may include one or more IBM DB2 extenders, Oracle data cartridges and/or Informix datablades, although other domain-specific extension modules may be used.

Li, Chung-Sheng↗

Method for calculating alloy energetics

A semiempirical method for the computation of alloy energies is introduced. It is based on the equivalent-crystal theory of defect-formation energies in elemental solids. The method is both simple and accurate. Heats of formation as a function of composition are computed for some binary alloys of Cu, Ni, Al, Ag, Pd, Pt, and Au using the heats of solution in the dilute limit as experimental input. The separation of heats into strain and chemical components helps in understanding the energetics. In addition, lattice-parameter contractions seen in solid solutions of Ag and Au are accurately predicted. Good agreement with experiment is obtained in all cases.

Bozzolo, Guillermo↗

Heats of formation of bcc binary alloys

The method of Bozzolo, Ferrante and Smith is applied for the calculation of alloy energies for bcc elements. The heat of formation of several alloys is computed with the help of the Connolly-Williams method within the tetrahedron approximation. The dependence of the results on the choice of different sets of ordered structures is discussed.

Bozzolo, Guillermo↗

Universal behavior in ideal slip

The slip energies and stresses are computed for defect-free crystals of Ni, Cu, Ag, and Al using the many-atom approach. A simple analytical expression for the slip energies is obtained, leading to a universal form for slip, with the energy scaled by the surface energy and displacement scaled by the lattice constant. Maximum stresses are found to be somewhat larger than but comparable with experimentally determined maximum whisker strengths.

Bozzolo, Guillermo↗

Global Expression for Representing Diatomic Potential-Energy Curves

A three-parameter expression that gives an accurate fit to diatomic potential curves over the entire range of separation for charge transfers between 0 and 1. It is based on a generalization of the universal binding-energy relation of Smith et al. (1989) with a modification that describes the crossover from a partially ionic state to the neutral state at large separations. The expression is tested by comparison with first-principles calculations of the potential curves ranging from covalently bonded to ionically bonded. The expression is also used to calculate spectroscopic constants form a curve fit to the first-principles curves. A comparison is made with experimental values of the spectroscopic constants.

Ferrante, John↗

Adhesion at metal interfaces

A basic adhesion process is defined, the theory of the properties influencing metallic adhesion is outlined, and theoretical approaches to the interface problem are presented, with emphasis on first-principle calculations as well as jellium-model calculations. The computation of the energies of adhesion as a function of the interfacial separation is performed; fully three-dimensional calculations are presented, and universality in the shapes of the binding energy curves is considered. An embedded-atom method and equivalent-crystal theory are covered in the framework of issues involved in practical adhesion.

Banerjea, Amitava↗