Engineering Papers⌕ Search

Engineering topics

Smith, J. M.

Publications and source records attributed to Smith, J. M..

At least 55 records · Page 3

Results of duct area ratio changes in the NASA Lewis H2-O2 combustion MHD experiment

MHD power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, generator loading B field strength, and electrode breakdown voltage were investigated. The effect of area ratio, multiple loading of the duct, and duct location within the magnetic field are considered.

Smith, J. M.↗

Design and preliminary results of a semitranspiration cooled /Lamilloy/ liner for a high-pressure high-temperature combustor

A Lamilloy combustor liner has been designed, fabricated and tested in a combustor at pressures up to 8 atmospheres. The liner was fabricated of a three layer Lamilloy structure and designed to replace a conventional step-louver liner. The liner will be used in a combustor that provides hot gases to a turbine cooling test facility at pressures up to 40 atmospheres. The Lamilloy liner was tested extensively at lower pressures and demonstrated lower metal temperatures than the conventional liner, while at the same time requiring about 40 percent less cooling air flow. Tests conducted at combustor exit temperatures in excess of 2200 K have not indicated any cooling or durability problems with the Lamilloy liner.

Wear, J. D.↗

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

The two diffusers employed in the investigation had the same overall area ratio but different prediffuser area ratios and suction slot geometries. Velocity profile and diffuser pressure recovery performance data were obtained at ambient pressure and temperature, with inlet Mach numbers ranging from 0.18 to 0.41 and suction rate varying from zero to 18% of total inlet mass flow rate. On the basis of the reported investigation it is concluded that suction stabilized vortex flow diffusers show promise for application in combustors because of relatively high static pressure recovery and low total pressure loss obtained in a short length. Performance obtained using a narrow angle (7 degree) prediffuser was superior to that obtained with a prediffuser having a 14 degree included angle.

Juhasz, A. J.↗

Performance of a short annular dump diffuser using suction-stabilized vortices at inlet Mach numbers to 0.41

A short, annular dump diffuser was designed to use suction to establish stabilized vortices on both walls for improved flow expansion in the region of an abrupt area change. The diffuser was tested at near ambient inlet pressure and temperature. The overall diffuser area ratio was 4.0. The inlet height was 2.54 cm and the exit pitot-static rakes were located at a distance from the vortex fence equal to two or six times the inlet height. Performance data were taken at near ambient temperature and pressure for nominal inlet Mach numbers of 0.18 to 0.41 with suction rates of 0 to 18 percent of the total inlet airflow. The exit velocity profile could be shifted toward either wall by adjusting the inner- or outer-wall suction rate. Symmetrical exit velocity profiles were unstable, with a tendency to shift back to hub- or tip-weighted profile. Diffuser effectiveness was increased from about 47 percent without suction to over 85 percent at a total suction rate of about 14 percent. The diffuser total pressure losses at inlet Mach numbers of 0.18 and 0.41 decreased from 1.1 and 5.6 percent without suction to 0.48 and 5.2 percent at total suction rates of 14.4 and 5.6 percent, respectively.

Smith, J. M.↗

Temperature distributions of a cesium-seeded hydrogen-oxygen supersonic free jet

The hydrogen-oxygen plasma was generated at combustion chamber pressures ranging from 0.5 to 2.0 megapascals and for various seed ratios (1 to 10 percent). The plasma was observed as the atmospheric exhaust from a Mach 2 rocket test facility. Transverse profiles of the absolute integrated intensity were measured with the optically thin CsI lines (0.5664 and 0.5636 microns) at a range of axial positions downstream of the 5-cm-diameter combustor nozzle exit. Radial profiles of the emission coefficient were obtained from the measured transverse profiles of intensity by Abel inversion. Temperatures were then determined from the emission coefficients for conditions of local thermodynamic equilibrium using particle densities generated by a two-dimensional free jet computer program. Temperature results show the inherent effects of compression and expansion pressure waves characteristic of a free jet exiting from a supersonic nozzle.

Wang, S. Y.↗

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

Test results are described for two abrupt area change annular diffusers with provisions for maintaining suction stabilized toroidal vortices at the area discontinuity. Both diffusers had an overall area ratio of 4.0 with the prediffuser area ratio being 1.18 for diffuser A and 1.4 for diffuser B. Performance was evaluated at near atmospheric pressure and temperature for a range of inlet Mach numbers from 0.18 to 0.41 and suction rates from 0 to 18%. Static pressure recovery improved significantly as the suction rate was increased to approximately 11%. Results obtained with diffuser A were superior to that obtained with diffuser B. Flat radial profiles of exit velocity were not obtained since the flow showed preferential hub or tip attachment at moderate suction rates. At high suction rates the diffuser exit flow became circumferentially nonuniform and unstable.

Juhasz, A. J.↗

Design and preliminary results of a semitranspiration cooled (Lamilloy) liner for a high-pressure high-temperature combustor

A Lamilloy combustor liner was designed, fabricated and tested in a combustor at pressures up to 8 atmospheres. The liner was fabricated of a three layer Lamilloy structure and designed to replace a conventional step louver liner. The liner is to be used in a combustor that provides hot gases to a turbine cooling test facility at pressures up to 40 atmospheres. The Lamilloy liner was tested extensively at lower pressures and demonstrated lower metal temperatures than the conventional liner, while at the same time requiring about 40 percent less cooling air flow. Tests conducted at combustor exit temperatures in excess of 2200 K have not indicated any cooling or durability problems with the Lamilloy linear.

Wear, J. D.↗

Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control

A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.

Juhasz, A. J.↗

Estimates of Optimal Operating Conditions for Hydrogen-Oxygen Cesium-Seeded Magnetohydrodynamic Power Generator

The value of percent seed, oxygen to fuel ratio, combustion pressure, Mach number, and magnetic field strength which maximize either the electrical conductivity or power density at the entrance of an MHD power generator was obtained. The working fluid is the combustion product of H2 and O2 seeded with CsOH. The ideal theoretical segmented Faraday generator along with an empirical form found from correlating the data of many experimenters working with generators of different sizes, electrode configurations, and working fluids, are investigated. The conductivity and power densities optimize at a seed fraction of 3.5 mole percent and an oxygen to hydrogen weight ratio of 7.5. The optimum values of combustion pressure and Mach number depend on the operating magnetic field strength.

Smith, J. M.↗

Velocity and temperature distributions of coal-slag layers on magnetohydrodynamic generators walls

Approximate analytical expressions are derived for the velocity and temperature distributions in steady state coal slag deposits flowing over MHD generator walls. Effects of slag condensation and Joule heating are included in the analysis. The transport conditions and the slag temperature at the slag-gas interface are taken to be known parameters in the formulation. They are assumed to have been predetermined either experimentally or from the slag properties and the gas dynamic calculations of the free stream flow. The analysis assumes a power law velocity profile for the slag and accounts for the coupling between the energy and momentum conservation equations. Comparisons are made with the more exact numerical solutions to verify the accuracy of the results.

Pian, C. C. P.↗

NASA policy on pricing shuttle launch services

The paper explains the rationale behind key elements of the pricing policy for STS, the major features of the non-government user policy, and some of the stimulating features of the policy which will open space to a wide range of new users. Attention is given to such major policy features as payment schedule, cost and standard services, the two phase pricing structure, optional services, shared flights, cancellation and postponement, and earnest money.

Smith, J. M.↗

Spectroscopic determination of electrical conductivity in an MHD duct from absolute intensity measurements

Measurements of the electrical conductivity in the NASA Lewis cesium seeded, H2-O2 MHD duct made by applying a voltage across the channel from one end electrode to the other, measuring the current, and using the inner electrodes as probes to monitor the voltage distribution along the channel were found to be in good agreement with theory except at low combustion pressures and/or high ratios of seed/oxygen mass flows. To corroborate these measurements and to analyze the possibility of nonuniform seed injection as a cause of the above deviations, a spectroscopic investigation of the plasma conductivity was undertaken. Radial profiles of emission coefficient were obtained from measured transverse profiles of the absolute integrated intensity by Abel inversion. Radial profiles of electrical conductivity were then obtained under two different assumptions. In the first the Cs seed fraction is assumed uniform and equal to the measured flow rate at the time when the temperature and conductivity were obtained. In the second method the local temperature and pressure are taken to be those given by a one-dimensional channel calculation including heat transfer and friction. The results of the two methods are compared to the previously measured conductivity.

Wang, S. Y.↗

A summary of the ECAS performance and cost results for MHD system

The interagency-funded, NASA-coordinated Energy Conversion Alternatives Study (ECAS) has studied the potential of various advanced power plant concepts using coal and coal-derived fuel. Principle studies were conducted through prime contracts with the General Electric Company and the Westinghouse Electric Corporation. The results indicate that open-cycle coal-fired direct-preheat MHD systems have potentially one of the highest coal-pile-to-bus-bar efficiencies and also one of the lowest costs of electricity (COE) of the systems studied. Closed-cycle MHD systems may have the potential to approach the efficiency and COE of open-cycle MHD. The 1200-1500 F liquid-metal MHD systems studied do not appear to have the potential of exceeding the efficiency or competing with the COE of advanced steam plants.

Seikel, G. R.↗

Results and progress on the NASA Lewis H2-O2 MHD program

A rocket test facility at the NASA Lewis Research Center has been used to develop interelectrode insulating materials, measure heat losses, and determine the fluid dynamic and electrical properties of MHD ducts and the cesium-seeded H2-O2 working fluid. Test results show that flame sprayed ceramic coatings on combustion chamber and nozzle walls permit operation with hot walls, eliminating problems associated with seed condensation; however, the net heat transfer was unexpectedly increased over that of cold copper walls. Pressure disturbances associated with oblique pressure waves were measured in a rocket nozzle designed to achieve low weight rather than perfectly parallel flow at the exit. Electrical conductivity measurements were in good agreement with theory except at low combustion pressures and/or high seed/oxygen mass flow ratios. The discrepancy is thought to result from poor atomization of the seed, producing droplets which do not completely vaporize during their residence time.

Smith, J. M.↗

Results and progress on the NASA Lewis H2-O2 MHD program

It was found that flame sprayed ceramic coatings on combustion chamber and nozzle walls permit operation with hot walls, thereby eliminating possible problems associated with seed condensation. However, under the conditions of experiment the net heat transfer was unexpectedly increased over that of cold copper walls. Pressure disturbances associated with oblique pressure waves were measured in a MHD channel. These disturbances are due to a rocket-type nozzle which was designed to achieve low weight rather than perfectly parallel flow at the exit. A new nozzle with parallel flow at the exit was designed. Electrical conductivity measurements agreed well with theory except at low combustion pressures and/or high ratios of seed/oxygen mass flows (seed was injected into oxygen flow line). The discrepancy is believed to be the result of poor atomization of the seed at high ratios of seed/oxygen mass flows which results in droplet sizes which do not completely vaporize the combustor.

Smith, J. M.↗

A summary of the ECAS performance and cost results for MHD systems

The potential is examined of various advanced power plant concepts using coal and coal-derived fuel. The results indicate that open cycle coal fired direct preheat MHD systems have potentially one of the highest coal-pile-to-bus-bar efficiencies and also one of the lowest costs of electricity (COE) of the systems studied. Closed cycle MHD systems may have the potential to approach the efficiency and COE of open cycle MHD. The 1200-1500 F liquid metal MHD systems studied do not appear to have the potential of exceeding the efficiency or competing with the COE of advanced steam plants.

Seikel, G. R.↗

Light bulb heat exchanger for magnetohydrodynamic generator applications - Preliminary evaluation

The light-bulb heat-exchanger concept is investigated as a possible means of using a combustion heat source to supply energy to an inert gas MHD power generator system. In this concept, combustion gases flow through a central passage which consists of a duct with transparent walls through which heat is transferred by radiation to a radiation receiver which in turn heats the inert gas by convection. The effects of combustion-gas emissivity, transparent-wall-transmissivity, radiation-receiver emissivity, and the use of fins in the inert gas coolant passage are studied. The results indicate that inert gas outlet temperatures of 2500 K are possible for combustion temperatures of 3200 K and that sufficient energy can be transferred from the combustion gas to reduce its temperature to approximately 2000 K. At this temperature more conventional heat exchangers can be used.

Smith, J. M.↗