Engineering topics
Smith, I. D.
Publications and source records attributed to Smith, I. D..
Fuel neutralization by ozone oxidation
The viability of a hazardous waste disposal system based on ozone oxidation of hydrazine fuels at low aqueous concentrations in the presence of ultraviolet light (UV at 2.537 x 10(exp -7) m or 8.324 x 10(exp -7) ft) excitation was investigated. Important parameters investigated include temperature, solution pH, and ultraviolet light power. Statistically relevant experimentation was done to estimate main factor effects on performance. The best available chemical analysis technology was used to evaluate the performance of the system.
The Determination of the Helium Saturation Level of Monomethylhydrazine and MON-3 Nitrogen Tetroxide
No abstract available
Site Alteration Effects from Rocket Exhaust Impingement During a Simulated Viking Mars Landing. Part 2: Chemical and Biological Site Alteration
Chemical and biological alteration of a Mars landing site was investigated experimentally and analytically. The experimental testing was conducted using a specially designed multiple nozzle configuration consisting of 18 small bell nozzles. The chemical test results indicate that an engine using standard hydrazine fuel will contaminate the landing site with ammonia (50-500ppm), nitrogen (5-50ppm), aniline (0.01-0.5ppm), hydrogen cyanide (0.01-0.5ppm), and water. A purified fuel, with impurities (mostly aniline) reduced by a factor of 50-100, limits the amount of hydrogen cyanide and aniline to below detectable limits for the Viking science investigations and leaves the amounts of ammonia, nitrogen, and water in the soil unchanged. The large amounts of ammonia trapped in the soil will make interpretation of the organic analysis investigation results more difficult. The biological tests indicate that the combined effects of plume gases, surface heating, surface erosion, and gas composition resulting from the retrorockets will not interfere with the Viking biology investigation.
Cleaning large tanks and gas bottles
Distillation technique using vapor solvent trichloromonofluoromethane is economical, effective, and eliminates need to enter tank, thus reducing risk of further contamination. Solvent can be purified for reuse.
Design certification tests: High Pressure Oxygen Filter (HPOF) program. Summary report
Design and acceptance certification test procedures and results are presented for a high pressure oxygen filter developed to protect the sealing surfaces in emergency oxygen systems. Equipment specifications are included.
Design certification tests: High Pressure Oxygen Filter (HPOF) program. Summary report (tables I through XLVI)
For abstract, see N77-16339.
Design certification tests High Pressure Oxygen Filter (HPOF) program, summary report (appendices A, B, and C)
For abstract, see N77-16339.
Pneumatic impact tests. Evaluation of the behavior of nonmetallic materials in hydrogen
Explore the source record for details and available documents.
Reaction propagation test. Evaluation of the behavior of nonmetallic materials in hydrogen
Results of tests conducted to evaluate the behavior of nonmetallic materials in hydrogen are described. The reaction propagation test simulates the conditions resulting from the interaction of an electrical wire in an overload condition in contract with a material in the test medium. The test is designed to evaluate the behavior of a material subjected to an energy input (usually heat) sufficient to cause a reaction which propagates to consume larger quantities of the material. Ten nonmetallic materials were evaluated to establish baseline data on the behavior of nonmetallic materials in hydrogen and to characterize, on an initial basis, one mode of material failure considered to be a factor pertinent to the safe use of a material in hydrogen.
The determination of the helium saturation level of AeroZINE-50 and nitrogen tetroxide
Bubble-point method and gas content-method for determining helium saturation level of AeroZINE-50 and nitrogen tetroxide
WSTF filter test program Interim report
Interface propellant filters tested for contamination holding capacity using water with particles between 0 to 100 microns
Nitrogen tetroxide disposal unit combustion products
Infrared spectroscopic analysis of combustion products released by nitrogen tetroxide disposal unit
Preliminary Performance Data Obtained in a Full-Scale Free-Jet Investigation of a Side-Inlet Supersonic Diffuser
Explore the source record for details and available documents.