Engineering PapersSearch

Engineering topics

Smith, A. C.

Publications and source records attributed to Smith, A. C..

Assessing the integrity of structural adhesive bonds by the measurement of acoustic properties

Results are reported of an experimental study tracing the influence of externally applied shear stresses on the acoustic properties in the bondline region. The changes in the acoustic properties with a change in the temperature of the test samples are measured. The results of these tests are employed to evaluate the quality of the adhesive bonds. The dependence of time-of-flight on the temperature of plain steel and of steel adhesively bonded to rubber is illustrated in graphic form.

Jagasivamani, V.

Ultrasonic study of adhesive bond quality at a steel-to-rubber interface by using quadrature phase detection techniques

The quadrature phase detection technique was used to simultaneously monitor the phase and amplitude of a toneburst signal normally reflected from an adhesively bonded steel-to-rubber interface. The measured phase was found to show a positive shift for all bonded samples with respect to the disbonded state - the phase shift being larger for samples with weaker bonds, as manifested by smaller values of applied tensile loads at failure. A model calculation, which incorporates the concept of interfacial strength into the usual problem of wave propagation in multilayered media, was used to deduce a bond-quality parameter from an experimentally measured phase shift. This bond-quality parameter was found to be correlated with the tensile strength of the adhesive bonds at failure loads.

Smith, A. C.

Measurement of the speed of sound in ice

The data presented demonstrate the gathering of sound speed measurements in refrigerated ice, using both compressional and shear waves, on the basis of ice thickness and sound wave time-of-travel parameters. Clear and sharp echo reflections were obtained for both compressional and shear waves at the aluminum/ice and ice/aluminum interfaces for ice at -26 C; ice formed at various conditions can have different sound speeds, depending on the density and elastic constants.

Smith, A. C.

A review of contamination issues associated with an orbiting Space Station external environment

Techniques for measuring, modeling, and limiting the effluent contamination of external spacecraft and instrument surfaces are reviewed, with an emphasis on their application to the Space Station. The major factors addressed by contamination studies are outlined; typical contamination sources are characterized; the critical measurement parameters are defined (molecular column density, background spectral intensity from UV to IR, particle size and velocity distribution, molecular deposition on ambient and cryogenic surfaces, molecular return flux for gaseous species, particulate deposition on surfaces, and optical-surface degradation); and measurement instrumentation is described. Contamination limits for quiescent operation periods of the Space Station are proposed, including column density 10 to the 11th/sq cm for H2O + CO2, 10 to the 13th/sq cm for O2 + N2, and 10 to the 10th/sq cm for other species; particle release no greater than 15-micron particle/orbit/0.00001 sr FOV for a 1-m telescope, and surface deposition 4 pg/sq cm sec for 298-K surfaces and 10 pg/sq cm sec for 4-K surfaces.

Smith, A. C.

Applications of mass spectrometry techniques to autoclave curing of materials

Mass spectrometer analysis of gases evolved from polymer materials during a cure cycle can provide a wealth of information useful for studying cure properties and procedures. In this paper data is presented for two materials to support the feasibility of using mass spectrometer gas analysis techniques to enhance the knowledge of autoclave curing of composite materials and provide additional information for process control evaluation. It is expected that this technique will also be useful in working out the details involved in determining the proper cure cycle for new or experimental materials.

Smith, A. C.

Application of mass spectrometry to process control for polymer material in autoclave curing

Mass spectrometer analysis of gas samples collected during a cure cycle of polymer materials can be used as a process control technique. This technique is particularly helpful in studying the various types of solvents and resin systems used in the preparation of polymer materials and characterizing the chemical composition of different resin systems and their mechanism of polymerization.

Smith, A. C.

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

Smith, A. C.

Ion-induced nucleation in a binary mixture

Recent ion-induced nucleation studies in a binary mixture of H2O and H2SO4 vapors indicate that conventional classical nucleation theories cannot account for the experimentally observed ion-H2O-H2SO4 microcluster spectra. An empirical-analytical, semi-molecular theory of nucleation of a binary mixture of vapors on ions has been developed. This theory includes molecular approach to ion-induced changes in dielectric properties in the immediate neighborhood of an ion core as well as the size dependence of the surface tension of the microcluster. In addition to gaseous sulfuric acid and water molecules, the effect of ion-hydrates and sulfuric acid hydrates has also been considered. This theory is further simplified by using an empirical correction factor for the electrostatic term. This correction factor has been obtained by comparing the simplified model with the molecular dynamics calculations for selected ion hydrate formation. These two theoretical models are then compared with the classical theory for a variety of experimental conditions.

Smith, A. C.

Experimental studies of the ion-induced binary nucleation

The aerosol nucleation phenomenon is studied in a binary mixture of H2O and H2SO4 vapors in a carrier stream of N2 gas in the presence of ions produced by a low energy beta source. Cluster spectra of the form (H2SO4)n.(H2O)m.H(+) are identified from the measurements of the cluster masses using a quadrupole mass spectrometer. Results show that the number of H2SO4 molecules in the clusters ranged from 0 to 6 whereas the number of H2O molecules ranged from 1 to 20 depending on the concentration of H2SO4 and H2O vapors in the reaction chamber. Among other conclusions, it is noted that a large number of clusters of the type investigated are formed in the presence of an ionization source even when the partial pressures of H2SO4 and H2O are very low. The cluster composition is found to be strongly dependent on the r.h. and r.a. values in the reaction cell. The cluster spectrum (n, m, l) contains a large number of low n- and low m-value clusters when the reaction cell pressure is high.

Singh, J. J.

Detection of trace quantities of dimethylacetamide during the curing process of a polyimide film

An experimental study of positive ion clustering of dimethylacetamide (DMAC) with water molecules using high pressure mass spectrometry techniques is reported. The possibilities of using these techniques to determine the concentration levels of DMAC evolved from a polyimide film during the curing process, are examined. The test sample of gas contained DMAC of the order of a few micrograms, water, nitrogen, oxygen, and other compounds that might evolve during the curing cycle of a polyimide film. It is found that PPM concentrations such as DMAC lost from polyimide during curing stages can be detected with this technique. Improvement of the detection of lower concentrations (50 picograms) can be made by using electron multipliers with a gain in the 10 to the 8th power range and pulse counting techniques.

Smith, A. C.

Experimental study of cluster formation in binary mixture of H2O and H2SO4 vapors in the presence of an ionizing radiation source

Molecular clusters formed in pure nitrogen containing H2O and H2SO4 vapors and exposed to a 3 mCi Ni63 beta source were studied in the mass range 50 to 780 amu using a quadrupole mass spectrometer. Measurements were made under several combinations of relative humidity and relative acidity ranging from 0.7 to 7.5 percent and 0.00047 to 0.06333 percent, respectively. The number of H2SO4 molecules in the clusters observed ranged from 1 to 7 whereas the number of H2O molecules ranged from 1 to 16. The experimental cluster spectra differ considerably from those calculated using the classical nucleation theory. First order calculations using modified surface tension values and including the effects of multipole moments of the nucleating molecules indicate that these effects may be enough to explain the difference between the measured and the calculated spectra.

Singh, J. J.

CdTe-HgTe heterostructures.

CdTe-HgTe heterostructures preparation with minimum energy gaps, showing photovoltaic effect caused by undesirable p-n junction due to Cd vacancy formation

Almasi, G. S.