Engineering Papers⌕ Search

Engineering topics

Smalley, Duane

Publications and source records attributed to Smalley, Duane.

At least 19 records

Compositional screening of Ce-doped (Gd,Lu,Y) 3 (Al,Ga) 5 O 12 ceramics prepared by quenching from melt and their luminescence properties

Quenching from the melt using an Optical Floating Zone furnace was investigated as a possible high-throughput preparation method in order to screen novel scintillating materials. To validate this method, polycrystalline rare-earth aluminum garnets and yttrium gallium aluminum garnets were synthesized and characterized by X-ray diffraction, photoluminescence and radioluminescence emission spectra as well as radioluminescence imaging and compared to the previously reported properties of those materials. In order to achieve rapid, but quantitative comparison of the materials, pellets fabricated from the synthesized powders were sintered; two different sintering conditions were investigated and compared. Therefore, a simplistic energy deposition and light absorption model for brightness of opaque samples under X-ray irradiation was developed to estimate the relative scintillation efficiency of the materials. Based on the results, Y 3 Al 5 O 12 , LuY 2 Al 5 O 12 and GdY 2 Al 5 O 12 seem to have the highest scintillation efficiency among the prepared samples.

36 MATERIALS SCIENCE↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is intended to be a fast-response, time-dependent beam diagnostic for measuring the spot size emitted from radiographic x-ray sources. It will measure spot sizes from submillimeters up to several millimeters for photon energies in the range of 150 keV to 20 MeV with doses as low as 0.03 rad up to 500 rad. The D-TRSD performs fast data acquisition as radiographic x-ray sources typically produce pulses in the tens of nanosecond ranges. The system will be optimized to capture multiple individual pulses in time within the same data record. The data collected will be used to support beam tuning and source optimization with on-the-fly evaluation of radiographic source performance. The diagnostic is based on penumbral imaging techniques. A scintillating fiber array of parallel aligned fibers is positioned in the beam path with a high-Z rolled edge inserted between the source and the array, thereby creating the penumbral x-ray signal that is captured by the D-TRSD system. The light from the scintillation conversion is recorded by individual avalanche photodiode detectors integrated into custom digitizer electronics. The penumbra is used to calculate the spot of the beam on the axis orthogonal to the fiber array based on the magnification from the rolled edge, the resolution of the spaced fibers, and the rotation of the array normal to the beam path. Many arrays can be used to capture additional spot widths about different rotations. The D-TRSD system is modular, software-driven, and easier to use than legacy TRSD systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is a fast-response, time-dependent beam diagnostic for measuring the emitted spot size and beam target interactions from radiographic x-ray sources. Legacy streaked TRSD analysis requires image processing and data extraction, which give noisy results. Processed data are used to extract edge spread and corresponding line spread functions. Digital TRSD simplifies this process, eliminating the complexity of streak camera–based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Disentangling Radiographic Contributions

Presentation describes research program and goal to understand all large radiographic contributions for a given image and assess if quantitative predictions can be made once contributions are understood, with current focus understanding scintillator response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash Radiography Studies with Microcolumnar CsI

There is growing interest in using low-energy flash x-ray sources in radiographic applications to provide high-contrast images of low-density objects. Due to the low-energy nature of the detected photons, thin bright scintillators are desired. In order to pursue an optimum radiographic system, experimental studies have been performed of the static imaging properties of thin microcolumnar CsI using a Platts x-ray source. The Platts source is a nominally 300 keV endpoint rod pinch diode x-ray source with a ~35 ns pulse time. The source was used to measure the imaging properties of microcolumnar CsI with various thicknesses and backings. The experimental setup was modeled in GEANT4, and the images were simulated to estimate system performance. Taking into account the source photon production, radiation transport, and system optical performance, an accurate assessment of the detection system can be deduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗