Engineering Papers⌕ Search

Engineering topics

Simpson, M.

Publications and source records attributed to Simpson, M..

Fungal community and functional responses to soil warming are greater than for soil nitrogen enrichment

Soil fungi are key regulators of forest carbon cycling and their responses to global change have effects that ripple throughout ecosystems. Global changes are expected to push many fungi beyond their environmental niches, but there are relatively few studies involving multiple, simultaneous global change factors. Here, we studied soil fungal diversity, community composition, co-occurrence patterns, and decomposition gene responses to 10 years of soil warming and nitrogen addition, alone and in combination. We specifically examined whether there were fungal community characteristics that could explain changes in soil carbon storage and organic matter chemistry in chronically warmed and fertilized soil. We found that fungal communities in warmed soils are less diverse and shift in composition. Warming also favored hyperdominance by a few mycorrhizal fungal species and lowered manganese peroxidase but increased hydrolytic enzyme encoding gene potentials. Nitrogen addition did not significantly affect fungal community composition but, like warming, did reduce fungal diversity and favored overdominance by a unique set of mycorrhizal taxa. Warming alone and in combination with nitrogen addition also reduced negative but increased positive fungal co-occurrence probabilities, promoting species coexistence. Negative fungal co-occurrence was positively correlated to soil carbon content, while the proportion of fungal hydrolytic enzyme encoding genes was negatively correlated with soil carbon content. This may reflect fungal life history trade-offs between competition (e.g., reduced negative co-occurrence) and resource acquisition (e.g., higher abundance of hydrolytic enzyme encoding genes) with implications for carbon storage.

54 ENVIRONMENTAL SCIENCES↗

Thin-Layer Electrodeposition of Uranium Metal from Molten LiCl-KCl

A uranium metal electrodeposition extension to the previously proposed analytical technique for determining actinides in molten salts is presented. The technique combines information from electrodeposition with the output of an alpha particle detector. This technique requires a thin actinide layer to be deposited on a metal substrate. Electrodeposition of a thorium layer has been reported previously. Electrodeposition of a thin uranium layer from molten LiCl-KCl onto nickel plates is reported in this paper using repeating chronoamperometry. Alloy formation was encountered which caused unusual deposit morphology. Furthermore, the effect of uranium concentration on time to deposit a fixed amount was determined. Re-usability of the detectors was shown via demonstrating the anodic stripping of the deposit verified by surface analysis (SEM-EDS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deployment of Behind-The-Meter Energy Storage for Demand Charge Reduction

This study investigates how economically motivated customers will use energy storage for demand charge reduction, as well as how this changes in the presence of on-site photovoltaic power generation, to investigate the possible effects of incentivizing increased quantities of behind-the-meter storage. It finds that small, short-duration batteries are most cost effective regardless of solar power levels, serving to reduce short load spikes on the order of 2.5% of peak demand. While profitable to the customer, such action is unlikely to adequately benefit the utility as may be desired, thus highlighting the need for modified utility rate structures or properly structured incentives.

25 ENERGY STORAGE↗

Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)

The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distribution feeder simulation.

25 ENERGY STORAGE↗

SPIDERS Bi-Directional Charging Station Interconnection Testing

The Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) program is a multi-year Department of Defense-Department of Energy (DOE) collaborative effort that will demonstrate integration of renewables into island-able microgrids using on-site generation control, demand response, and energy storage with robust security features at multiple installations. Fort Carson, Colorado, will be the initial development and demonstration site for use of plug-in electric vehicles as energy storage (also known as vehicle-to-grid or V2G).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Sizing of Energy Storage and Photovoltaic Power Systems for Demand Charge Mitigation (Poster)

Commercial facility utility bills are often a strong function of demand charges -- a fee proportional to peak power demand rather than total energy consumed. In some instances, demand charges can constitute more than 50% of a commercial customer's monthly electricity cost. While installation of behind-the-meter solar power generation decreases energy costs, its variability makes it likely to leave the peak load -- and thereby demand charges -- unaffected. This then makes demand charges an even larger fraction of remaining electricity costs. Adding controllable behind-the-meter energy storage can more predictably affect building peak demand, thus reducing electricity costs. Due to the high cost of energy storage technology, the size and operation of an energy storage system providing demand charge management (DCM) service must be optimized to yield a positive return on investment (ROI). The peak demand reduction achievable with an energy storage system depends heavily on a facility's load profile, so the optimal configuration will be specific to both the customer and the amount of installed solar power capacity. We explore the sensitivity of DCM value to the power and energy levels of installed solar power and energy storage systems. An optimal peak load reduction control algorithm for energy storage systems will be introduced and applied to historic solar power data and meter load data from multiple facilities for a broad range of energy storage system configurations. For each scenario, the peak load reduction and electricity cost savings will be computed. From this, we will identify a favorable energy storage system configuration that maximizes ROI.

14 SOLAR ENERGY↗

Plug-In Electric Vehicle Fast Charge Station Operational Analysis with Integrated Renewables: Preprint

The growing, though still nascent, plug-in electric vehicle (PEV) market currently operates primarily via level 1 and level 2 charging in the United States. Fast chargers are still a rarity, but offer a confidence boost to oppose 'range anxiety' in consumers making the transition from conventional vehicles to PEVs. Because relatively no real-world usage of fast chargers at scale exists yet, theNational Renewable Energy Laboratory developed a simulation to help assess fast charging needs based on real-world travel data. This study documents the data, methods, and results of the simulation run for multiple scenarios, varying fleet sizes, and the number of charger ports. The grid impact of this usage is further quantified to assess the opportunity for integration of renewables;specifically, a high frequency of fast charging is found to be in demand during the late afternoons and evenings coinciding with grid peak periods. Proper integration of a solar array and stationary battery thus helps ease the load and reduces the need for new generator construction to meet the demand of a future PEV market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Targeting Net Zero Energy at Fort Carson: Assessment and Recommendations

The U.S. Army's Fort Carson installation was selected to serve as a prototype for net zero energy assessment and planning. NREL performed the comprehensive assessment to appraise the potential of Fort Carson to achieve net zero energy status through energy efficiency, renewable energy, and electric vehicle integration. This report summarizes the results of the assessment and provides energyrecommendations. This study is part of a larger cross-laboratory effort that also includes an assessment of renewable opportunities at seven other DoD Front Range installations, a microgrid design for Fort Carson critical loads and an assessment of regulatory and market-based barriers to a regional secure smart grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Full load shop testing of 18,000-hp gas turbine driven centrifugal compressor for offshore platform service: Evaluation of rotor dynamics performance

The results for in-plant full load testing of a 13.4 MW (18000 HP) gas turbine driven centrifugal compressor are presented and compared to analytical predictions of compressor rotor stability. Unique problems from both oil seals and labyrinth gas seals were encountered during the testing. The successful resolution of these problems are summarized.

Kirk, R. G.↗

Influence of dendrite network defects on channel segregate growth

The solidifying ingot interdendritic flow analysis in which channel segregates are assumed to be produced by interdendritic fluid flow dissolving channels in the primary dendrite network is presently refined by examining the flow through a dendrite network possessing a small defect. Attention is given to the section of the mushy zone in a solidifying casting. Since defects such as that presently treated are unavoidable in a real casting, a more reliable indication may be furnished of the occurrence of channel segregates.

Simpson, M.↗

Effects of gravity on interdendritic flow - An analytic approach

The present investigation attempts to provide an aid to the understanding of the essence of the gravitational influence on interdendritic flow. An analytic solution of the equations governing interdendritic fluid flow is presented for a simple case, involving a semiinfinite mushy zone whose isotherms are flat, parallel, and inclined at an angle to the force of gravity. It is found that gravity in ingots with narrow mushy zones mainly produces interdendritic flow parallel to the liquidus confined to the vicinity of the liquidus. This flow can be large in comparison to the usual shrinkage-induced flows. Its existence is caused by the rapid increase of permeability with fraction liquid near the liquidus. For this reason, it cannot appear in numerical calculations which ignore the rapid variation of permeability.

Simpson, M.↗