Engineering Papers⌕ Search

Engineering topics

Silver, E.

Publications and source records attributed to Silver, E..

Microcalorimeters with Germanium Thermistors for High Resolution Soft and Hard X-ray Astronomy

This is a progress report for the first year of a three year Space Research and Technology (SR&T) grant to continue the advancement of neutron transmutation doped (NTD-based) microcalorimeters. We have re-prioritized certain aspects of the statement of work and chose to emphasize issues of array development in the first year rather than wait until year two. Consequently, some of the projects scheduled for the first year were delayed to the second year. Here we report on our progress to: a) Build and test a 1 x 4 element array and to investigate electrical and thermal cross-talk; b) Build a multiplexed 4 channel analog pulse processor; c) Build a digital pulse processor that can accommodate 4 channels with independent triggers; d) Develop a proportional thermal baseline restoration system compatible with the constant voltage mode of microcalorimeter operation.

Silver, E.↗

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.↗

X-Ray and Gamma-Ray Astronomy with NTD Germanium-based Microcalorimeters

We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.

Silver, E.↗

B-MINE: The Balloon-Borne Microcalorimeter Nuclear Line Explorer

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the 44Ti emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3 sigma sensitivity in 10 (exp 6) s of 3.3 x 10(exp -7) ph cm(exp -2) s(exp -1) at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroid and width in CAS A.

Silver, E.↗

The Constellation-X Focal Plane Microcalorimeter Array: An NTD-Germanium Solution

The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral 'flying' leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element instruments. Details of construction are presented.

Beeman, J.↗

Laboratory Astrophysics and Microanalysis with NTD-Germanium-Based X-Ray Microcalorimeter

With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high resolution x-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or x-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and x-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.

Silver, E.↗

Feasibility of KTa(1-x)Nb(x)O3 as a dielectric or pyroelectric microcalorimeter

We are developing a dielectric microcalorimeter for X-ray spectroscopy. We will present the results of our measurement of the dielectric permittivity, the spontaneous polarization, and the pyroelectric coefficient of the mixed-crystal quantum ferroelectric KTa(1-x)Nb(x)O3 with a doping of x = 0.012, as a function of temperature and bias voltage across the device. The effects of surface layers on the permittivity and the pyroelectric coefficient are discussed. We also show the signal results from infrared LED and alpha-particle radiation.

Pfafman, T. E.↗

Predicted performance of the lithium scattering and graphite crystal polarimeter for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is greatly enhanced if these polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the three components of the Stellar X-Ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The experiment will reside at the focus of one of the SODART X-ray telescopes. The expected on-axis performance of these two components of the Stellar X-Ray Polarimeter experiment based on detailed Monte-Carlo simulation is described. Various systematic effects, both external and internal to the experiment, that must be considered in order to properly design and utilize the experiment are also discussed.

Weisskopf, M. C.↗

Bragg crystal polarimeter for the Spectrum-X-Gamma mission

A Bragg crystal polarimeter for the focal plane of the SODART telescope on the Spectrum-X-Gamma mission is being designed. A mosaic graphite crystal will be oriented at 45 deg to the optic axis of the telescope, thereby preferentially reflecting those X-rays which satisfy the Bragg condition and have electric vectors that are perpendicular to the plane defined by the incident and reflected photons. The reflected X-rays will be detected by an imaging proportional counter with the image providing direct X-ray aspect information. The crystal will be about 50 microns thick to allow X-rays with energies of 4 keV or greater to be transmitted to a lithium block mounted below the graphite. The lithium is used to measure the polarization of these high energy X-rays by exploiting the polarization dependence of Thomson scattering. The development of thin mosaic graphite crystals is discussed and recent reflectivity, transmission, and uniformity measurements are presented.

Holley, J.↗

Bragg crystal polarimeters

A Bragg crystal oriented at 45 deg to an incoming beam of X-rays acts as a polarization analyzer. This crystal geometry preferentially reflects those X-rays that satisfy the Bragg condition and whose electric vectors are perpendicular to the plane defined by the incident and reflected photons. X-rays with electric vectors parallel to this plane of incidence are photoelectrically absorbed. The energy bandwidth of nearly perfect crystals is extremely small, which makes them very inefficient X-ray polarimeters. This limitation is particularly acute for observations of the relatively weak X-ray continuum of stellar sources. The bandwidth can be greatly increased by employing mosaic or ideally imperfect crystals. Mosaic crystals possess a high integrated reflectivity, which results in a large increase in the reflection of continuum radiation. A review of the theory and performance characteristics of crystal polarimeters designed for observations of cosmic X-ray sources is presented.

Silver, E.↗

Off-axis effects on the performance of a scattering polarimeter at the focus of an X-ray telescope

Scattering from bound electrons in a suitable material placed at the focus of an X-ray telescope can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. Among the factors that affect the performance of such an instrument is a spurious polarization signal from unpolarized sources that lie within the field of view but are offset from the telescope pointing direction. This paper presents the results of analytical and Monte Carlo studies of this effect and provides means of evaluating its impact on realistic polarimeters for X-ray astronomy.

Elsner, R. F.↗

The Stellar X-ray Polarimeter - A focal plane polarimeter for the Spectrum X-Gamma mission

This paper describes an X-ray polarimeter that will be flown on the Spectrum X-Gamma mission. The instrument exploits three distinct physical processes to measure polarization: Bragg reflection from a graphite crystal, Thomson scattering from a metallic lithium target, and photoemission from a cesium iodide photocathode. These three methods allow polarization measurements over an energy band from 0.3 to 12 keV. The polarimeter will make possible sensitive measurements of several hundred known X-ray sources. X-ray polarization measurements will make it possible to constrain the geometry of gas flow in X-ray binaries, identify nonthermal emission in supernova remnants, test current models for X-ray emission in radio pulsars, determine the radiation mechanisms in active galactic nuclei, and search for inertial frame dragging (Lense-Thirring effect) around the putative black hole in Cygnus X-1.

Kaaret, P.↗

On the performance of the scattering and crystal polarimeters for the Spectrum-X-Gamma mission

X-ray scattering from a lithium disk and Bragg reflection from a mosaic graphite crystal can be exploited to measure the linear polarization of radiation emitted from cosmic X-ray sources. The sensitivity is enhanced if the polarimeters are placed at the focus of an X-ray telescope. Such devices form two of the components of the Stellar X-ray Polarimeter experiment scheduled to fly on the Spectrum-X-Gamma mission. The expected on-axis performance of the two components is described based on detailed Monte Carlo simulations. The polarimetry experiment is expected to provide sensitive measurements of linear polarization for many cosmic X-ray sources. The nature and utility of such observations is described for pulsing X-ray sources such as the Crab pulsar and Her X-1.

Elsner, R. F.↗

Test results of a prototype dielectric microcalorimeter

The initial development work on a dielectric microcalorimeter is presented. It focuses on the dielectric properties of the ferroelectric material KTa(1-x)Nb(x)O3 (KTN). Measurements of the temperature dependent dielectric constant are given together with the first alpha particle detection results from a prototype composite microcalorimeter operating at 1.3 K. A nonthermal mechanism for detecting 6 MeV alpha particles in a monolithic KTN sample is also reported.

Pfafman, T. E.↗