Engineering Papers⌕ Search

Engineering topics

Siegmund, Oswald H. W.

Publications and source records attributed to Siegmund, Oswald H. W..

The Cosmic Origins Spectrograph

The Cosmic Origins Spectrograph (COS) is a moderate-resolution spectrograph with unprecedented sensitivity that was installed into the Hubble Space Telescope (HST) in May 2009, during HST Servicing Mission 4 (STS-125). We present the design philosophy and summarize the key characteristics of the instrument that will be of interest to potential observers. For faint targets, with flux F(sub lambda) approximates 1.0 X 10(exp -14) ergs/s/cm2/Angstrom, COS can achieve comparable signal to noise (when compared to STIS echelle modes) in 1-2% of the observing time. This has led to a significant increase in the total data volume and data quality available to the community. For example, in the first 20 months of science operation (September 2009 - June 2011) the cumulative redshift pathlength of extragalactic sight lines sampled by COS is 9 times that sampled at moderate resolution in 19 previous years of Hubble observations. COS programs have observed 214 distinct lines of sight suitable for study of the intergalactic medium as of June 2011. COS has measured, for the first time with high reliability, broad Lya absorbers and Ne VIII in the intergalactic medium, and observed the HeII reionization epoch along multiple sightlines. COS has detected the first CO emission and absorption in the UV spectra of low-mass circumstellar disks at the epoch of giant planet formation, and detected multiple ionization states of metals in extra-solar planetary atmospheres. In the coming years, COS will continue its census of intergalactic gas, probe galactic and cosmic structure, and explore physics in our solar system and Galaxy.

Green, James C.↗

An Observational Test of Transition Region Lines as a Pressure Gauge

The objective of this research project was to use high resolution spectroscopic observations from the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) instrument on SOHO (Solar and Heliospheric Observatory) to study the structure of the solar transition region. Our main focus in this grant was to study the variation in density and emission across the quiet Sun transition region.

Siegmund, Oswald H. W.↗

A coronal mass ejection model for the 1992 July 15 flare on AU Microscopii observed by the extreme ultraviolet explorer

The dM1e flare star AU Microscopii (AU Mic) was observed by the EUVE Deep Survey Instrument on 1992 July 14-18. A large flare was detected in the Deep Survey Lexan/Boron (DS Lex/B)(65-190 A) band and the SW (70-190 A) and MW (140-380 A) spectrometers. The flare consisted of a sharp impulsive peak lasting approximately 2 hours followed by a decaying tail lasting about a day. We present a simple, single temperature, dynamic model for the flare decay which is consistent with the DS Lex/B light curve and reproduces the strongest, high-temperature spectral lines in the released EUVE spectra. In this model, we assume the long decay time is due to an ejected, magnetically confined, low beta plasmoid expanding self similarly in the ambient medium in a manner reminiscent of solar coronal mass ejections. We demonstrate that the long tail of the DS Lex/B light curve can be explained by rapid expansion, causing the plasma to become tenuous sufficiently quickly that it avoids catastrophic radiative cooling. From this model, we estimate the mass of the plasmoid to be approximately = 10(exp 20) g and the total energy of the event to be approximately = 10(exp 36) ergs. These values are approximately 10(exp 4) times as large as those seen during the largest solar coronal mass ejection (CME) events. We argue that the results of our model are consistent with other measurements of stellar flare parameters. We also estimate a mass-loss rate of a few times 10(exp -13) Solar mass/yr and discuss the role of mass loss from dMe stars in the mass balance of the interstellar medium. We estimate the rotational braking timescale from these events to be less than 500 million years and suggest that CME's may be an important source of angular momentum loss from late-type stars.

Cully, Scott L.↗

Extreme Ultraviolet Explorer deep survey observations of a large flare on AU Microscopii

We have made the first extended observation of a stellar flare in the EUV with 100 s time resolution. The flare was detected on AU Mic by the Extreme Ultraviolet Explorer satellite at 12:38 UT on 1992 July 15 during a 4 d observation from 1992 July 14 to 18. This was a large flare detected in the Lexan/boron (65-190 A) band with an observed peak count rate of 7.0 +/- 0.5 counts/s, corresponding to a peak luminosity of 10 exp 30 erg/s in the Lexan/boron bandpass. This is significantly above the measured quiescent level of 0.4 +/- 0.2 counts/s. The flare consisted of a sharp peak lasting about 2 hr, followed by a decaying tail that lasted more than a day. The total EUV energy of the event is estimated to be 3 x 10 exp 34 ergs. A second, smaller flare was also observed and is described. We conclude that the large emission measures on order of 6 x 10 exp 53/cu cm are due to large volumes with characteristic length scales of order the stellar radius. We compare these EUV observations with stellar flare observations in other bandpasses and estimate the likelihood of seeing similar flares in future observations.

Cully, Scott L.↗

Extreme Ultraviolet Explorer observations of the magnetic cataclysmic variable RE 1938-461

The magnetic cataclysmic variable RE 1938-461 was observed by the Extreme Ultraviolet Explorer (EUVE) Deep Survey instrument on 1992 July 8-9 during in-orbit calibration. It was detected in the Lexan/ boron (65-190 A) band, with a quiescent count rate of 0.0062 +/- 0.0017/s, and was not detected in the aluminum/carbon (160-360 A) band. The Lexan/boron count rate is lower than the corresponding ROSAT wide-field camera Lexan/boron count rate. This is consistent with the fact that the source was in a low state during an optical observation performed just after the EUVE observation, whereas it was in an optical high state during the ROSAT observation. The quiescent count rates are consistent with a virtual cessation of accretion. Two transient events lasting about 1 hr occurred during the Lexan/boron pointing, the second at a count rate of 0.050 +/- 0.006/s. This appears to be the first detection of an EUV transient during the low state of a magnetic cataclysmic variable. We propose two possible explanations for the transient events.

Warren, John K.↗

Characteristics of square pore and low noise microchannel plate stacks

An evaluation is conducted of several square-pore microchannel plates (MCPs) with either 25- or 85-micron diameter pores and 80:1 or 50:1 channel length/diameter ratio. Flat field measurements show that the 25-micron-pored MCPs, unlike those with 85-micron pores, exhibit periodic modulation; this may be due to the MCP stacking configurations. Attention is given to the relative quantum detection efficiency advantages of the two MCPs.

Siegmund, Oswald H. W.↗

Extreme ultraviolet quantum detection efficiency of rubidium bromide opaque photocathodes

Measurements are presented of the quantum detection efficiency (QDE) of three samples of RbBr photocathode layers over the 44-150-A wavelength range. The QDE of RbBr-coated microchannel plate (MCP) was measured using a back-to-back Z-stack MCP configuration in a detector with a wedge and strip position-sensitive anode, of the type described by Siegmund et al. (1984). To assess the stability of RbBr layer, the RbBr photocathode was exposed to air at about 30 percent humidity for 20 hr. It was found that the QDE values for the aged cathode were within the QDE measurement errors of the original values. A simple QDE model was developed, and it was found that its predictions are in accord with the QDE measurements.

Siegmund, Oswald H. W.↗

Photoelectron energy spectra of opaque photocathodes in the extreme and far ultraviolet

Measurements of the EUV quantum detection efficiency (QDE) of opaque RbBr, CsBr, and KBr photocathodes are described and investigations of their photoemission characteristics over the 44-1560 A wavelength range are reported. The results show that high QDEs can be obtained in the EUV. Narrow QDE peaks at soft X-ray wavelengths occur at slightly different wavelengths for each of the materials studied. The long-wavelength thresholds vary according to the material band gap. Data on the photoemission from the photocathode layer on the microchannel plate interchannel web area are used to determine the number and energy distribution of the emitted photoelelectrons as a function of wavelength.

Siegmund, Oswald H. W.↗

Soft X-ray and extreme utraviolet quantum detection efficiency of potassium chloride photocathode layers on microchannel plates

The quantum detection efficiency (QDE) of KCl photocathodes in the 44-1460 A range was investigated. An opaque layer of KCl, about 15,000-A-thick, was evaporated and applied the surface of a microchannel plate (MCP), and the contribution of the photocathode material in the channels (and on the interchannel web) to the QDE was measured using a Z stack MCP detector. It is shown that KCl is a relatively stable photocathode material, with the QDE equal to 30-40 percent in the EUV. At wavelengths above 200 A, the QDE is slightly better than the QDE of CsI, as reported by Siegmund et al. (1986). While the shape of the QDE curve as a function of wavelength is similar to those reported for CsI and KBr, KCl was found to lack the high QDE peak found in the curves of CsI and KBr at about 100 A. A simple QDE model is described, the predictions of which were found to agree with the measurements on the KCl photocathode.

Siegmund, Oswald H. W.↗

Ultraviolet quantum detection efficiency of potassium bromide as an opaque photocathode applied to microchannel plates

The quantum detection efficiency (QDE) of potassium bromide as a photocathode applied directly to the surface of a microchannel plate over the 250-1600 A wavelength range has been measured. The contributions of the photocathode material in the channels and on the interchannel web to the QDE have been determined. Two broad peaks in the QDE centered at about 450 and about 1050 A are apparent, the former with about 50 percent peak QDE and the latter with about 40 percent peak QDE. The photoelectric threshold is observed at about 1600 A, and there is a narrow QDE minimum at about 750 A which correlates with 2X the band gap energy for KBr. The angular variation of the QDE from 0 to 40 deg to the channnel axis has also been examined. The stability of Kbr with time is shown to be good with no significant degradation of QDE at wavelengths below 1216 A over a 15-day period in air.

Siegmund, Oswald H. W.↗