Engineering Papers⌕ Search

Engineering topics

Sidik, S. M.

Publications and source records attributed to Sidik, S. M..

At least 37 records · Page 2

Preliminary analysis of an extensive one year survey of trace elements and compounds in the suspended particulate matter in Cleveland, Ohio

Preliminary review of a study of trace elements and compound concentrations in the ambient suspended particulate matter in Cleveland, Ohio, measured from August 1971 through June 1973, as a function of source, monitoring location, and meteorological conditions. The study is aimed at the development of techniques for identifying specific pollution sources which could be integrated into a practical system readily usable by an enforcement agency.

King, R. B.↗

Two-dimensional Gaussian processes applied to the determination of contact between lubricated rolling surfaces

Theoretical investigation of how effectively a lubricant film prevents metallic contact between two rolling surfaces (such as in ball bearings) as a function of surface roughness parameters. The parameters considered are the spectral moments of the two-dimensional surface obtained by superposition of the two rolling surfaces. We consider the peak height distribution, estimation of one-dimensional profile spectral moments, and the estimation of two-dimensional surface moments from several profile measurements are taken into account. Also given is an asymptotic relation between the mean film thickness and contact occurrences.

Sidik, S. M.↗

On evaluating compliance with air pollution levels 'not to be exceeded more than once per year'

The point of view taken is that the Environmental Protection Agency (EPA) Air Quality Standards (AQS) represent conditions which must be made to exist in the ambient environment. The statistical techniques developed should serve as tools for measuring the closeness to achieving the desired quality of air. It is shown that the sampling frequency recommended by EPA is inadequate to meet these objectives when the standard is expressed as a level not to be exceeded more than once per year and sampling frequency is once every three days or less frequent.

Neustadter, H. E.↗

On evaluating compliance with air pollution levels 'not to be exceeded more than once a year'

Under a sampling program operated in conformity with EPA guidelines, calculational procedures are described for estimating the corresponding ambient pollution level. The statistical independence of the data, the commutativity of expectation and exponential operations, and the statistical variability of the calculated results are quantitatively evaluated. It is shown that the recommended sampling frequencies of every third to every sixth day are inadequate in determining conformity when the standards are expressed as levels not to be exceeded more than once a year.

Neustadter, H. E.↗

Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

Neustadter, H. E.↗

On evaluating compliance with air pollution levels not to be exceeded more than once per year

The adequacy is considered of currently practiced monitoring and data reduction techniques for assessing compliance with 24-hour Air Quality Standards (AQS) not to be exceeded more than once per year. The present situation for suspended particulates is discussed. The following conclusions are reached: (1) For typical less than daily sampling (i.e., 60 to 120 24-hour samples per year) the deviation from independence of the data set should not be substantial. (2) The interchange of exponentiation and expectation operations in the EPA data reduction model, underestimates the second highest level by about 4 to 8 percent for typical sigma values. (3) Estimates of the second highest pollution level have associated with them a large statistical variability arising from the finite size of the sample. The 0.95 confidence interval ranges from + or - 40 percent for 120 samples per year to + or - 84 percent for 30 samples per year. (4) The design value suggested by EPA for abatement and/or control planning purposes typically gives a margin of safety of 60 to 120 percent.

Neustadter, H. E.↗

Preliminary analysis of an extensive one year survey of trace elements and compounds in the suspended particulate matter in Cleveland, Ohio

Beginning in 1971 a cooperative program has been carried on by the City of Cleveland Division of Air Pollution Control and NASA Lewis Research Center to study the trace element and compound concentrations in the ambient suspended particulate matter in Cleveland Ohio as a function of source, monitoring location and meteorological conditions. The major objectives were to determine the ambient concentration levels at representative urban sites and to develop a technique using trace element and compound data in conjunction with meteorological conditions to identify specific pollution sources which could be developed into a practical system that could be readily utilized by an enforcement agency.

King, R. B.↗

Two-dimensional Gaussian processes applied to the determination of contact between lubricated rolling surfaces

The effectiveness of a lubricant film preventing metallic contact between two rolling surfaces (such as in ball bearings) as a function of surface roughness parameters was investigated. The parameters considered are the spectral moments of the two-dimensional surface obtained by superposition of the two rolling surfaces. The peak height distribution, estimation of one-dimensional profile spectral moments, and the estimation of two-dimensional surface moments from several profile measurements were considered. Also given is an asymptotic relation between the mean film thickness and contact occurrences.

Sidik, S. M.↗

An algorithm for generating all possible 2(p-q) fractional factorial designs and its use in scientific experimentation

An algorithm and computer program are presented for generating all the distinct 2(p-q) fractional factorial designs. Some applications of this algorithm to the construction of tables of designs and of designs for nonstandard situations and its use in Bayesian design are discussed. An appendix includes a discussion of an actual experiment whose design was facilitated by the algorithm.

Sidik, S. M.↗

Analysis of electrical contact occurrences between rolling surface with application to elastohydrodynamic lubrication

A mathematical model enabling the relation of electrical contact occurrences between rolling surfaces to the mean thickness of an elastohydrodynamic lubricant film is discussed. A previous development by other authors is shown to contain an error invalidating their results. Some potentially useful approximations are developed for the case when the lubricant film is large with respect to the surface roughness. Complete solutions that are valid for all film thicknesses are not yet available.

Sidik, S. M.↗

Statistical summary and trend evaluation of air quality data for Cleveland, Ohio in 1967 to 1971: Total suspended particulate, nitrogen dioxide, and sulfur dioxide

Air quality data for Cleveland, Ohio, for the period of 1967 to 1971 were collated and subjected to statistical analysis. The total suspended particulate component is lognormally distributed; while sulfur dioxide and nitrogen dioxide are reasonably approximated by lognormal distributions. Only sulfur dioxide, in some residential neighborhoods, meets Ohio air quality standards. Air quality has definitely improved in the industrial valley, while in the rest of the city, only sulfur dioxide has shown consistent improvement. A pollution index is introduced which displays directly the degree to which the environmental air conforms to mandated standards.

Neustadter, H. E.↗

Kullback-Leibler information function and the sequential selection of experiments to discriminate among several linear models

The error variance of the process prior multivariate normal distributions of the parameters of the models are assumed to be specified, prior probabilities of the models being correct. A rule for termination of sampling is proposed. Upon termination, the model with the largest posterior probability is chosen as correct. If sampling is not terminated, posterior probabilities of the models and posterior distributions of the parameters are computed. An experiment was chosen to maximize the expected Kullback-Leibler information function. Monte Carlo simulation experiments were performed to investigate large and small sample behavior of the sequential adaptive procedure.

Sidik, S. M.↗

Kullback-Leibler information function and the sequential selection of experiments to discriminate among several linear models

A sequential adaptive experimental design procedure for a related problem is studied. It is assumed that a finite set of potential linear models relating certain controlled variables to an observed variable is postulated, and that exactly one of these models is correct. The problem is to sequentially design most informative experiments so that the correct model equation can be determined with as little experimentation as possible. Discussion includes: structure of the linear models; prerequisite distribution theory; entropy functions and the Kullback-Leibler information function; the sequential decision procedure; and computer simulation results. An example of application is given.

Sidik, S. M.↗

An improved multiple linear regression and data analysis computer program package

NEWRAP, an improved version of a previous multiple linear regression program called RAPIER, CREDUC, and CRSPLT, allows for a complete regression analysis including cross plots of the independent and dependent variables, correlation coefficients, regression coefficients, analysis of variance tables, t-statistics and their probability levels, rejection of independent variables, plots of residuals against the independent and dependent variables, and a canonical reduction of quadratic response functions useful in optimum seeking experimentation. A major improvement over RAPIER is that all regression calculations are done in double precision arithmetic.

Sidik, S. M.↗

NAMER: A FORTRAN 4 program for use in optimizing designs of two-level factorial experiments given partial prior information

Under certain specified conditions, the Bayes procedure for designing two-level fractional factorial experiments is that which maximizes the expected utility over all possible choices of parameter-estimator matchings, physical-design variable matchings, defining parameter groups, and sequences of telescoping groups. NAMER computes the utility of all possible matchings of physical variables to design variables and parameters to estimators for a specified choice of defining parameter group or groups. The matching yielding the maximum expected utility is indicated, and detailed information is provided about the optimal matchings and utilities. Complete documentation is given; and an example illustrates input, output, and usage.

Sidik, S. M.↗