Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of K-Shell Al and Mg and L-Shell Mo Radiation from Compact Cylindrical Wire Array Plasmas Produced on the 1 MA UNR Zebra Generator

K-shell radiation of Al and Mg and L-shell radiation of Mo from implosions of compact cylindrical wire arrays (CCWA) on the 1 MA UNR Zebra generator was studied. Specifically, radiation from implosions of 3 and 6 mm CCWA with (16-24) Al-5052 (95% Al and 5% Mg) and Al-5052 (97.5% Al and 2.5% Mg) and Mo wires was analyzed using the full set of diagnostics: PCD and current signals, and X-ray pinhole images and spectra. Previously developed non-LTE models were applied to model spatially resolved time integrated as well as time-gated spatially integrated spectra from Al, Mg, and Mo plasmas. Derived electron temperature and density spatial gradients as well as percentage of radiating mass were studied and compared. In addition, the novel Wire Dynamics Model (WDM) was used to analyze the implosion dynamics of compact wire array loads.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray diagnostics of imploding plasmas from planar wire arrays composed of Cu and few tracer Al wires on the 1MA pulsed power generator at UNR

Tracer aluminum alloyed wires (Al5056) are used to provide additional information for x-ray diagnostics of implosions of Cu planar wire arrays (PWAs). Specifically, the analysis of combined PWA experiments using the extensive set of x-ray diagnostics is presented. In these experiments, which were conducted at the 1MA pulsed power generator at University of Nevada, Reno, the Z-pinch load consisted of several (eight) Cu alloyed (main material) and one to two Al alloyed (tracer) wires mounted in a single plane row or double parallel plane rows, single planar wire array (SPWA) or double planar wire array (DPWA), respectively. The analysis of x-ray spatially resolved spectra from the main material indicates the increase in the electron temperature T{sub e} near the cathode. In general, the axial gradients in T{sub e} are more pronounced for SPWA than for DPWA due to the more 'columnlike' plasma formation for SPWA compared to 'hot-spot-like' plasma formation for DPWA. In addition, x-ray spectra from tracer wires are studied, and estimated plasma parameters are compared with those from the main material. It is observed that the x-ray K-shell Al spectra manifest more opacity features for the case of SPWA with about 18% of Al mass (to the total load mass) compared to the case of DPWA with about 11% of Al mass. The analysis of time-gated spectra shows that the relative intensity of the most intense K-shell Al line, small before the x-ray burst, increases with time and peaks close to the maximum of the sub-keV signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic of charge balance in high-temperature tungsten plasmas using LLNL EBIT

Diagnostic of high-temperature M-shell W plasmas is challenging because of contribution of numerous ionization stages in a relatively narrow x-ray spectral region. A method using LLNL EBIT data generated at different electron beam energies has been established for the identification of prominent spectral features and for the determination of charge balance in x-ray M-shell W spectra between 3.5 and 8.5 A . It extends previous work [A. S. Safronova et al., Can. J. Phys. 86, 267 (2008)] which used only Ni-like lines to include the neighboring ionization stages. This diagnostic procedure was tested with results from Z-pinch plasmas produced on the 1 MA pulse power generator Zebra at UNR. These results are of particular importance for fusion research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy and implosion dynamics of low wire number nested arrays on the 1 MA COBRA generator

Low wire number nested array Z-pinch experiments have been carried out with wires made of aluminum, stainless steel (uniform), and combinations of these two materials (mixed) on the 1 MA COBRA generator at Cornell University [J. D. Douglass, J. B. Greenly, D. A. Hammer et al., in Proceedings of the 15th IEEE International Pulsed Power Conference (IEEE, Piscataway, NJ, 2005)]. The outer array consisted of eight wires, whereas the inner array had four or eight wires. The 10 {mu}m Al wires were alloy 5056 and the 6.25 {mu}m stainless steel wires were alloy SS304. The diagnostic suite included fast-x-ray and extreme ultraviolet (EUV) detectors, a time-gated x-ray pinhole camera, x-ray spectrometers, and laser shadow imaging. The main focus was made on the spectroscopic study of plasma evolution after the main x-ray burst though the data from photoconducting detector (PCD) and EUV signals over the whole period of current, and in addition laser shadowgraphy images before the main x-ray burst were analyzed. Modeling of the time-gated spectra recorded after the main x-ray burst indicates that the electron temperature Te either follows the PCD signals and peaks at times of the second (and the third if present) x-ray burst or has the higher value at the first frame (closest to the main x-ray burst), then slightly changes and increases at the last frame, which coincides with the second maximum of the current. It was also found that the values of Te never drop below 150 eV, and the EUV signal remains intense even when the PCD signal is almost zero.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double planar wire array as a compact plasma radiation source

Magnetically compressed plasmas initiated by a double planar wire array (DPWA) are efficient radiation sources. The two rows in a DPWA implode independently and then merge together at stagnation producing soft x-ray yields and powers of up to 11.5 kJ/cm and more than 0.4 TW/cm, higher than other planar arrays or low wire-number cylindrical arrays on the 1 MA Zebra generator. DPWA, where precursors form in two stages, produce a shaped radiation pulse and radiate more energy in the main burst than estimates of implosion kinetic energy. High radiation efficiency, compact size (as small as 3-5 mm wide), and pulse shaping show that the DPWA is a potential candidate for ICF and radiation physics research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Temperature, Density, and Particle Transport with Localized Dopants in Wire-Array Z Pinches

Axially localized NaF dopants are coated onto Al cylindrical wire arrays in order to act as spectroscopic tracers in the stagnated z-pinch plasma. Non-local-thermodynamic-equilibrium kinetic models fit to Na K-shell lines provide an independent measurement of the density and temperature that is consistent with spectroscopic analysis of K-shell emissions from Al and an alloyed Mg dopant. Axial transport of the Na dopant is observed, enabling quantitative study of instabilities in dense z-pinch plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of conical wire array Z-pinch implosions

A modification of the wire array Z pinch, the conical wire array, has applications to the understanding of wire array implosions and potentially to pulse shaping relevant to inertial confinement fusion. Results are presented from imploding conical wire array experiments performed on university scale 1 MA generators--the MAGPIE generator (1 MA, 240 ns) at Imperial College London [I. H. Mitchell et al., Rev. Sci Instrum. 67, 1533 (1996)] and the Nevada Terawatt Facility's Zebra generator (1 MA, 100 ns) at the University of Nevada, Reno [B. Bauer et al., in Dense Z-Pinches, edited by N. Pereira, J. Davis, and P. Pulsifer (AIP, New York, 1997), Vol. 409, p. 153]. This paper will discuss the implosion dynamics of conical wire arrays. Data indicate that mass ablation from the wires in this complex system can be reproduced with a rocket model with fixed ablation velocity. Modulations in the ablated plasma are present, the wavelength of which is invariant to a threefold variation in magnetic field strength. The axial variation in the array leads to a zippered precursor column formation. An initial implosion of a magnetic bubble near the cathode is followed by the implosion zippering upwards. Spectroscopic data demonstrating a variation of plasma parameters (e.g., electron temperature) along the Z-pinch axis is discussed, and experimental data are compared to magnetohydrodynamic simulations.