Radiant coolers - Theory, flight histories, design comparisons and future applications

Radiant coolers have been developed for application to the cooling of infrared detectors aboard NASA earth observation systems and as part of the Defense Meteorological Satellite Program. The prime design constraints for these coolers are the location of the cooler aboard the satellite and the satellite orbit. Flight data from several coolers indicates that, in general, design temperatures are achieved. However, potential problems relative to the contamination of cold surfaces are also revealed by the data. A comparison among the various cooler designs and flight performances indicates design improvements that can minimize the contamination problem in the future.

Donohoe, M. J.

Cryogenic and low temperature heat pipe/cooler studies for spacecraft application

The prime purpose of the present work is to examine cryogenic heat pipe/cooler feasibility in the 80 to 100 K temperature range and in the regimes of operation required for NASA spacecraft. Present requirements within these regimes are (1) cooling load of less than 1 to 2 watt per cooler, (2) small detector/heat pipe interface area, and (3) high system reliability and long lifetime operations. The cooling capacity of practical radiant coolers is very low in this temperature range, and very temperature sensitive. Detector performance is also strongly dependent on temperatures in this regime. It is, therefore important to understand the interplay of the heat pipe and its effects on overall system performance.

Sherman, A.

Selected Vuilleumier refrigerator performance characteristics

Study of the performance characteristics of the Vuilleumier refrigerator for spacecraft applications. The effect on refrigerator performance of several important components and design parameters is examined. The components and design parameters selected for investigation include the cold-end heat conductance, cold regenerator, refrigerator rpm, and refrigerator sump temperature.

Sherman, A.

Multiple slot laminar film cooling.

An analytical investigation is presented showing the effect of film cooling using single and double slots. The analysis considers the tangential injection of a gas of the same molecular weight as the main flow into a laminar boundary layer. Results in terms of heat transfer to the wall are presented for different slot heights, and injection velocities for both single and double slot configurations. The results indicate that the double slot is a more effective means of film cooling than the single slot.

Sherman, A.

Mathematical analysis of a Vuilleumier refrigerator.

A comprehensive analysis of the Vuilleumier refrigerator was conducted. This analysis includes the effects of nonisothermal gas heat addition and rejection, hot and cold regenerator inefficiencies, conduction losses, and gas leakage losses. A computer program was written which solves the equations resulting from the analysis. The program calculates internal pressures, temperatures, and gas flow rates as functions of refrigerator crank angle, as well as overall refrigerator cooling load and power input. Comparisons between the program results and available data show good agreement, with a marked improvement over the predictions of the ideal model.

Sherman, A.

Arterial and grooved cryogenic heat pipes.

Tests were conducted on two cryogenic heat pipes using nitrogen as the working fluid. Both pipes are 1.27 cm in diameter. The first pipe is 141 cm long and uses longitudinal grooves in the aluminum wall as the wick structure. The second pipe is 91 cm long and has an arterial wick adjacent to the wall. In addition, circumferential screw threads are machined along the entire length of the inside pipe wall. Both heat pipes primed with no difficulty in the horizontal position. Start-up after burn-out was obtained repeatedly. However, more testing is required to determine whether the artery pipe is as reliable as the grooved pipe with respect to priming. Once primed, the artery heat pipe is much less sensitive to elevation than the grooved design and, consequently, offers a significant advantage with respect to ground testing. Heat-transfer characteristics of the two pipes were comparable, with both pipes achieving the initial goal of 1000 watt-cm of heat-transport capability.

Brennan, P.

Fluid properties handbook

Single source compilation handbook, has been made of the most accurate available physical property data pertaining to helium, hydrogen, oxygen, and nitrogen.

Gershman, R.