Engineering Papers⌕ Search

Engineering topics

Shen, Bo

Publications and source records attributed to Shen, Bo.

At least 73 records · Page 4

Optimization of Residential Air Source Heat Pump using Low–Global Warming Potential Refrigerants

We report low–global warming potential refrigerants can significantly reduce the direct emissions of CO 2 originating from HVAC systems. However, high-efficiency systems are needed to reduce indirect CO 2 emissions. In this study, an R410A residential 5-Ton heat pump was optimized using R32, R454A, R454B, R454C, and R455A. Among these options, R455A and R454C have the lowest global warming potential but have lower volumetric capacity and high glide. Optimization results using 5 mm tube heat exchangers showed 12.4% to 19.1% efficiency improvements and 13% to 33% reduction in CO 2 emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset of ultralow temperature refrigeration for COVID 19 vaccine distribution solution

Abstract Most COVID-19 vaccines require temperature control for transportation and storage. Two types of vaccine have been developed by manufacturers (Pfizer and Moderna). Both vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (−80 °C to −60 °C), while the Moderna vaccine requires −30 °C storage. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine at the required temperature. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages, including safety concerns due to human exposure to large amounts of CO 2 from dry-ice sublimation, issues due to the pressure increase caused by dry-ice sublimation, and the potential issue caused by non-uniform cryogenic temperatures. As such, there is a need for test dataset to assist the development of a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics.

60 APPLIED LIFE SCIENCES↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Tungsten disulfide nanotubes enhance flow-induced crystallization and radio-opacity of polylactide without adversely affecting in vitro toxicity

Treatment of vascular disease, from peripheral ischemia to coronary heart disease (CHD), is poised for transformation with the introduction of transient implants designed to “scaffold” regeneration of blood vessels and ultimately leave nothing behind. Improved materials could expand the use of these devices. Here, we examine one of the leading polymers for bioresorbable scaffolds (BRS), polylactide (PLA), as the matrix of nanocomposites with tungsten disulfide (WS 2 ) nanotubes (WSNT), which may provide mechanical reinforcement and enhance radio-opacity. We evaluate in vitro cytotoxicity using vascular cells, flow-induced crystallization and radio-opacity of PLA-WSNT nanocomposites at low WSNT concentration. A small amount of WSNT (0.1 wt%) can effectively promote oriented crystallization of PLA without compromising molecular weight. And radio-opacity improves significantly: as little as 0.5 to 1 wt% WSNT doubles the radio-opacity of PLA-WSNT relative to PLA at 17 keV. The results suggest that a single component, WSNT, has the potential to increase the strength of BRS to enable thinner devices and increase radio-opacity to improve intraoperative visualization. Here, the in vitro toxicity results indicate that PLA-WSNT nanocomposites are worthy of investigation in vivo. Although substantial further preclinical studies are needed, PLA-WSNT nanocomposites may provide a complement of material properties that may improve BRS and expand the range of lesions that can be treated using transient implants.

36 MATERIALS SCIENCE↗

A study on computational fluid dynamics modeling of a refrigerated container for COVID-19 vaccine distribution with experimental validation

A key issue with the distribution of vaccines to prevent COVID-19 is the temperature level required during transport, storage, and distribution. Typical refrigerated transport containers can provide a temperature-controlled environment down to -30 °C. However, the Pfizer vaccine must be carefully transported and stored under a lower temperature between -80 °C and -60 °C. One way to provide the required temperature is to pack the vaccine vials into small packages containing dry ice. Dry ice sublimates from a solid to a gas, which limits the allowable transport duration. This can be mitigated by transporting in a -30 °C refrigerated container. Moreover, because the dry ice will sublimate and thereby release CO 2 gas into the transport container, monitoring the CO 2 concentration within the refrigerated container is also essential. In the present work, a 3D computational fluid dynamics model was developed based on a commercially available refrigerated container and validated with experimental data. The airflow, temperature distribution, and CO 2 concentration within the container were obtained from the simulations. The modeling results can provide guidance on preparing experimental setups, thus saving time and lowering cost, and also provide insight into safety precautions needed to avoid hazardous conditions associated with the release of CO 2 during vaccine distribution.

59 BASIC BIOLOGICAL SCIENCES↗

COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. Furthermore, the approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

60 APPLIED LIFE SCIENCES↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulations of Grid-Responsive HVAC Cooling Measures via Ice/PCM storage

This study uses EnergyPlus building energy simulations to assess grid-responsive HVAC cooling measures during peak hours having high electricity price, including: lock the high capacity of a two-speed cooling coil during grid-response hours; and use ice/PCM energy storage to drive a chilled water coil and meet the cooling load, when shut off the main electric cooling coil. Here, the impacts on peak power reductions, energy and utility cost savings, and comfort levels in residential buildings of two U.S. cities were revealed.

Shen, Bo↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crystal structure engineering in multimetallic high-index facet nanocatalysts

Significance Crystal structure engineering in nanoparticles represents an important strategy in catalyst design, as catalytic performance is highly dependent on atomic arrangement. However, realizing crystal structure engineering in high-index facet nanocatalysts has been a synthetic challenge for decades. Here, we first employed density functional theory calculations to determine whether surface modifications can stabilize high-index facets during crystal structure transformations and then synthesized a library of multimetallic high-index facet tetrahexahedral (THH) nanoparticles with controllable crystal structures. Importantly, the crystal structural transition between the intermetallic and chemically disordered states is reversable, and the THH morphology of nanocatalysts is maintained during this transformation. This approach broadens the synthetic scope of nanocatalysts available for use in diverse chemical processes.

Shen, Bo↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗