Engineering Papers⌕ Search

Engineering topics

Sharma, S.

Publications and source records attributed to Sharma, S..

65 records · Page 4

A magnetically shielded room with ultra low residual field and gradient

A versatile and portable magnetically shielded room with a field of (700 ± 200) pT within a central volume of 1 m × 1 m × 1 m and a field gradient less than 300 pT/m, achieved without any external field stabilization or compensation, is described. This performance represents more than a hundredfold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus. This has implications for developments of magnetometry beyond the femto-Tesla scale in, for example, biomagnetism, geosciences, and security applications and in general low-field nuclear magnetic resonance (NMR) measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The R&D of NSLS-II Girder Profiling

A precise state-of-the-art vibrating wire technique will be adopted to achieve the challenging ±30 μm magnet-magnet positioning requirement in NSLS-II storage ring. However, girder profile variation after relocation will merge all the efforts of precise magnet alignment. Girder profiling, a 2-steps process including baseline establishment and restoration in tunnel which never been applied before in accelerator field, will be implemented to keep the girder profile between magnetic measurement room and tunnel as close as possible. Laser tracker is chosen as the main instrument. Tests in environmentally controlled room indicate that a repeatability accuracy of ±10 μm can be achieved by laser tracker in several days period and it has the resolution of better than ±5 μm if serving as an indicator. Simulations and tests prove that an accuracy of better than ±10 μm can be achieved for both steps; therefore, the final magnet-magnet alignment accuracy can be better than ±20 μm. Most of the R&D activities will be presented.

36 MATERIALS SCIENCE↗

Magnetic and Mechanical Center Deviations of NSLS-II Magnets

Ideally Mechanical center coincides with magnetic center for a perfectly manufactured magnet. However, this is not the case in a real world. This requires magnet should be magnetically fiducialized and aligned to reduce the error that caused by this kind of discrepancy. A high-precision and costly vibrating wire system is used in NSLS-II project to align all the magnets in one common girder magnetically with a precision better than ±10 micron. It can be deemed as a ruler to gauge the magnetic and mechanical center deviation for NSLS-II magnets. This information will be useful for future accelerator regarding alignment technique selection.

36 MATERIALS SCIENCE↗

Simulation study of wave phenomena from the sheath region in single frequency capacitively coupled plasma discharges; field reversals and ion reflection

Capacitively coupled radio-frequency (RF) discharges have great significance for industrial applications. Collisionless electron heating in such discharges is important, and sometimes is the dominant mechanism. This heating is usually understood to originate in a stochastic interaction between electrons and the electric fields. However, other mechanisms may also be important. There is evidence of wave emission with a frequency near the electron plasma frequency, i.e., ω{sub pe}, from the sheath region in collisionless capacitive RF discharges. This is the result of a progressive breakdown of quasi-neutrality close to the electron sheath edge. These waves are damped in a few centimeters during their propagation from the sheath towards the bulk plasma. The damping occurs because of the Landau damping or some related mechanism. This research work reports that the emission of waves is associated with a field reversal during the expanding phase of the sheath. Trapping of electrons near to this field reversal region is observed. The amplitude of the wave increases with increasing RF current density amplitude J(tilde sign){sub 0} until some maximum is reached, beyond which the wave diminishes and a new regime appears. In this new regime, the density of the bulk plasma suddenly increases because of ion reflection, which occurs due to the presence of strong field reversal near sheath region. Our calculation shows that these waves are electron plasma waves. These phenomena occur under extreme conditions (i.e., higher J(tilde sign){sub 0} than in typical experiments) for sinusoidal current waveforms, but similar effects may occur with non-sinusoidal pulsed waveforms for conditions of experimental interest, because the rate of change of current is a relevant parameter. The effect of electron elastic collisions on plasma waves is also investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft Computing Methods in Design of Superalloys

Soft computing techniques of neural networks and genetic algorithms are used in the design of superalloys. The cyclic oxidation attack parameter K(sub a), generated from tests at NASA Lewis Research Center, is modelled as a function of the superalloy chemistry and test temperature using a neural network. This model is then used in conjunction with a genetic algorithm to obtain an optimized superalloy composition resulting in low K(sub a) values.

Cios, K. J.↗

Soft computing methods in design of superalloys

Soft computing techniques of neural networks and genetic algorithms are used in the design of superalloys. The cyclic oxidation attack parameter K(sub a), generated from tests at NASA Lewis Research Center, is modeled as a function of the superalloy chemistry and test temperature using a neural network. This model is then used in conjunction with a genetic algorithm to obtain an optimized superalloy composition resulting in low K(sub a) values.

Cios, K. J.↗

Measurement-based performance evaluation technique for high-performance computers

A measurement-based performance evaluation technique has been used to characterize the OS performance of Cedar, a hierarchical shared-memory multiprocessor system. Thirteen OS performance meters were used to capture the operating system activities for compute-bound workloads. Three representative applications from the Perfect Benchmark Suite were used to measure the OS performance in a dedicated system and in multiprogrammed workloads. It was found that 13-23 percent of the total execution time on a dedicated system was spent in executing OS-related activities. Under multiprogramming, 12-14 percent of the total execution time was used by the OS. The impact of multiprogramming on the operating system performance meters was also measured.

Sharma, S.↗

Tests Of A Differential Global Positioning System

Paper describes validation tests of global positioning system (GPS) for low-flying helicopters. Configured as differential GPS, in which components in both aircraft and ground station compute position errors relative to known location using satellite navigational data. Corrections computed from differences between computed and measured ranges to four satellites being tracked by receiver in both aircraft and ground systems. Tests conducted to determine whether equipment and computer programs of system operated correctly and consistently.

Edwards, F. G.↗

Validating the airborne and ground based components of a differential GPS system

A differential GPS mechanization of an external data link concept under development at NASA Ames Research Center is discussed. The system is intended to evaluate the use of differential GPS to support helicopter approach operation. Analytical techniques for static testing and evaluation of the system hardware and software performance in real time are described. Several techniques that have been used to detect and rectify a specific problem encountered during the tests are dicussed. An example of flight test results using the validated system is provided.

Edwards, F. G.↗