Engineering Papers⌕ Search

Engineering topics

Shah, A. P.

Publications and source records attributed to Shah, A. P..

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Magnification Faraday Rotation Imaging and Analysis of X-pinch Implosion Dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 μm), a short axial extent (<1 mm), and a short duration (.1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x-rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. To study the current distribution in the coronal plasma throughout the implosion process, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the 1-MA, 100-ns MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10&times;), this diagnostic achieves a spatial resolution of approximately 35 μm, which is useful for resolving the ~100-μm-scale coronal plasma region immediately surrounding the dense core. Combined with the corresponding interferogram, which provides the radial density distribution in the low-density coronal plasma, the measured rotation can be used to diagnose the delivery of the driver current, and thus the magnetic drive pressure, to the micro-pinch plasma as it approaches minimal radius. Using this technique on MAIZE, we have measured

Dowhan, G. V.↗

Optimization of switch diagnostics on the MAIZE linear transformer driver

The MAIZE Linear Transformer Driver is made of 40 capacitor-switch-capacitor `bricks' connected in parallel. When these 40 bricks are charged to 100-kV and then discharged synchronously, the MAIZE facility generates a 1-MA current pulse with a 100-ns rise time into a matched load impedance. Discharging each of the capacitors in a brick is carried out by the breakdown of a spark-gap switch, a process which results in the emission of light. Monitoring this output light with a fiber optic coupled to a photomultiplier tube (PMT) and an oscilloscope channel provides information on switch performance and timing jitter– whether a switch red early, late, or in phase with the other switches. However, monitoring each switch with a dedicated detector- oscilloscope channel can be problematic for facilities where the number of switches to be monitored (e.g., 40 on MAIZE) greatly exceeds the number of detector-oscilloscope channels available. The technique of using fibers to monitor light emission from switches can be optimized by treating a PMT as a binary digit or bit and using a combinatorial encoding scheme, where each switch is monitored by a unique combination of fiber- PMT-oscilloscope channels simultaneously. By observing the unique combination of ber-PMT-oscilloscope channels that are turned on, the pre-firing or late-firing of a single switch on MAIZE can be identified by as few as six PMT-oscilloscope channels. The number of PMT-oscilloscope channels, N , required to monitor X switches can be calculated by 2 N = X + 1, where the number '2' is selected because the PMT-oscilloscope acts as a bit. Here, we demonstrate the use of this diagnostic technique on MAIZE. In conclusion, we also present an analysis of how this technique could be scaled to monitor the tens of thousands of switches proposed for various next generation pulsed power facilities.

47 OTHER INSTRUMENTATION↗