Engineering Papers⌕ Search

Engineering topics

Serkowski, Jason E.

Publications and source records attributed to Serkowski, Jason E..

Recovery of Oxpure 612C-50 Coconut Carbon Particles Using Bump Arrays

Cyanide is used to leach gold from crushed ore (solid matrix) into a gold cyanide solution. The gold is extracted from the cyanide solution by adsorption onto activated carbon. The gold extraction process occurs when the activated coconut carbon is placed into tanks that contain the gold cyanide solution either in a batch process or into a continuous flow circuit. The coconut carbon is then removed from the solution for gold recovery. The use of the mesofluidic separation system (a deterministic lateral displacement system) can significantly reduce costs and waste generated from the process of removing the coconut carbon from the solution. In the coconut carbon recovery process used at many gold mines in Nevada, the gold is attached to carbon particles that are still in the cyanide liquor. The mesofluidic system can rapidly remove the gold bearing carbon particles from the cyanide liquor quickly and with no operating costs. The benefits include: • Reduce operational costs related to filtration and hydro-cyclones • Reduced acid usage for the elution gold stripping phase as only 25% of the fluids will follow the carbon particles to the final express lane when two mesofluidic systems are used in series This alternative particle removal techniques would be advantageous. A promising technique for removing larger particles from slurries is mesofluidic separation, similar to deterministic lateral displacement arrays or “bump” arrays [1] but operates at much larger flow rates. As described by Pease, et al. [2], “Bump arrays in deterministic lateral displacement devices separate large particles from small particles using arrays of staggered posts. Large particles, defined as those with radii larger than the distance between the edge of a post and the stagnation streamline from the next downstream post, must bump toward one side of the device, whereas particles smaller than this distance slalom from entrance to exit without net lateral displacement.” Unlike filters or sieves, the posts in the arrays that cause separation do not block or occlude particle flow but work because particles go around the posts. Unlike hydrocyclones separation, separation is not driven by particle density, because gravitational forces are unimportant to mesofluidic separation. Burns, et al., and Pease, et al., have shown that particles may be separated from complex suspensions, under turbulent flow conditions, and at industrially important flow rates [3-5]. They have also recently shown that mesofluidic devices may be arranged in series to increase separation performance [6]. In this paper, we evaluate the mesofluidic system for the separation of commercial OxPure GR 612 Charred Coconut shell particles as a proof of principle test for the rapid separation using the 1500 micron cut mesofluidic separator. We first describe the experimental system and conditions. We then present the experimental results. [1] Huang, L.R., E.C. Cox, R.H. Austin, J.C. Sturm. 2004. Continuous particle separation through deterministic lateral displacement. Science, 304, 987–990. https://doi.org/10.1126/science.1094567. [2] Pease L.F., J.A. Bamberger, C.A. Burns, and M.J. Minette. 2021. Large Particle Separation from Non-Newtonian Slurries using Bump Arrays. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-65904, V003T08A023. New York, New York: ASME. doi:10.1115/FEDSM2021-65904 [3] Burns C.A., T.G. Veldman, J. Serkowski, R.C. Daniel, X.-Y. Yu, M.J. Minette, L.F. Pease. 2021. Mesofluidic separation versus dead-end filtration. Separation and Purification Technology, 254, 117256. https://doi.org/10.1016/j.seppur.2020.117256. [4] Pease L.F., J.E. Serkowski, T.G. Veldman, J. Williams, X.-Y. Yu, M.J. Minette, J.A. Bamberger, C.A. Burns. 2021. Can Bump Arrays Separate Particles from Turbulent Flows?. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-67696, V003T08A024. New York, New York: ASME. doi:10.11

mesofluidic separation, slurry, bump array↗

Targeted Particle Fractionation Technologies: Proof of Concept

Most methods of particle-size analysis involve particle fractionation which, is often done by filtration or the use of screens. This paper provides proof of concept testing for new in-pipe particle fractionation technologies that can be used at laboratory to industrial scales. These technologies are extensions of recent advancements in bump arrays as well as testing of new inline angled-to-the-flow slats, and advanced boycott-based Avalanche separation technologies. Experiments were conducted for three targeted particle fractionation technologies to evaluate the in-pipe removal of oversized sands in Newtonian slurries prior to the introduction of bump arrays. The mesofluidic system uses an array of staggered posts as configured in a bump array for Newtonian slurry conditions. The methods and results of these experiments are described in this paper. This information could be applied in most industrial and laboratory systems to rapidly remove oversized particles from a flowing slurry.

slurry, solids removal, particle fractionation, bu↗

Comparing Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Full and Tapered Bump Arrays

To separate particles from carrier fluids arrays of staggered posts inserted into the flow stream can be employed. The smaller particles follow the flow stream while the larger particles move laterally to one side. During flow, the concentration of particulate increases in one direction and decreases in the other crosswise direction. This technique separates the particles from the carrier fluid. Experiments using a slurry with non-Newtonian rheology were conducted to evaluate large particle separation from the non-Newtonian carrier fluid using bump arrays. The bentonite kaolin clay slurry with non-Newtonian rheology was spiked with large diameter inert glass particles. Experiments with flow through lateral displacement arrays evaluated the performance of particle separation using two array configurations: a full array with all posts and a tapered array with posts removed in a triangular portion of the array past the rows of anticipated particle of separation. The posts are staggered posts to promote particle segregation to one side of the flow channel. Using this type of array for removing particles from non-Newtonian yield stress slurries is novel and we present unique results. In this paper, the performance of full and tapered arrays are compared. These results have many industrial applications including removing particles from slurries of nuclear waste. Large particle removal is an important step in waste processing.

slurry, solids removal, deterministic lateral disp↗

Experimental Results for Large Particle Separation from Non-Newtonian Slurries Using Tapered Bump Arrays

Lateral displacement arrays are useful for separating particles such as blood cells and sand from carrier fluids. These arrays consist of staggered posts, which allow smaller particles to follow streamlines and larger particles to flow around the posts and migrate to one side. This migration increases the particle concentration in one direction and depletes the particle concentration in the other direction allowing particle separation to occur. Experiments were conducted to separate large particles in non-Newtonian yield stress slurries using tapered bump arrays. The non-Newtonian slurry used was composed of a bentonite kaolin blend with the inclusion of larger diameter particles. These experiments were conducted to evaluate the performance of particle separation using a tapered array of staggered posts as configured in a bump array for non-Newtonian yield stress slurries, an application that has not been explored experimentally. A theory for large particle separation was developed for slurries that exhibit Bingham or Cross rheology. The results of these experiments are described. This information could be applied in industrial settings such as separation of particles from nuclear waste slurries including those to be processed at the Hanford site, where removing large particles from waste streams is important to processing.

slurry, solids removal, deterministic lateral disp↗

Industrial scale mesofluidic particle separation

Here we explore the potential of a mesofluidic separator that fits within industrial piping and is designed to remove large aspherical particles out of an abrasive slurry at fast flow rates. Mesofluidic separators have recently demonstrated separation of spherical particles at flow rates of ~1 gallon/min (gpm) (6.3.10 -5 m 3 /s). Yet, the performance of these separators at flow rates achievable within industrial piping have not been explored. Here we evaluate the permeate flowrate fraction, large particle mass fraction, and pressure drop from approximately 35-100 gpm (2.2.10-3-6.3.10-3 m 3 /s) in a three inch tube using an abrasive and modestly non-spherical slurry. Faster flow rates may be achieved with larger pumps and larger diameters. We find the permeate fraction and pressure drop both increase with flow rate, though the pressure drop remains modest. Only two feet of inserts removed 97.6±2.1% of large particles for conditions tested. Separation was demonstrated in both vertical and horizontal orientations with the horizontal orientation benefiting marginally from gravitational settling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can Bump Arrays Separate Particles from Turbulent Flows?

In this paper, we evaluate the hypothesis that bump arrays can be used to separate particles from turbulent flows entering the array. Microfluidic bump arrays are known for separating particles by size from laminar inlet flows. However, turbulent inlet flows have not been explored but become important as microfluidic bump arrays are scaled up to mesofluidic bump arrays. We find experimentally that particle separation is indeed effective at higher Reynolds numbers. These experimental findings portend industrial scale particle separation due to the higher flow rates they facilitate.

Pease, Leonard F.↗