Engineering Papers⌕ Search

Engineering topics

Senesac, Larry R

Publications and source records attributed to Senesac, Larry R.

Infrared microcalorimetric spectroscopy using quantum cascade lasers

We have investigated an infrared (IR) microcalorimetric spectroscopy technique that can be used to detect the presence of trace amounts of target molecules. The chemical detection is accomplished by obtaining the IR photothermal spectra of molecules absorbed on the surface of uncooled thermal micromechanical detectors. IR microcalorimetric spectroscopy requires no chemical specific coatings and the chemical specificity of the presented method is a consequence of the wavelength-specific absorption of IR photons from tunable quantum cascade lasers due to vibrational spectral bands of the analyte. We have obtained IR photothermal spectra for trace concentrations of RDX and a monolayer of 2-mercaptoethanol, over the wavelength region from 6 to 10 m. We found that in this wavelength region both chemicals exhibit a number of photothermal absorption features that are in good agreement with their respective IR spectra.

IR specttoscopy↗

Standoff imaging of chemicals using IR spectroscopy

Here we report on a standoff spectroscopic technique for identifying chemical residues on surfaces. A hand-held infrared camera was used in conjunction with a wavelength tunable mid-IR quantum cascade laser (QCL) to create hyperspectral image arrays of a target with an explosive residue on its surface. Spectral signatures of the explosive residue (RDX) were extracted from the hyperspectral image arrays and compared with a reference spectrum. Identification of RDX was achieved for residue concentrations of 20 g per cm2 at a distance of 1.5 m, and for 5 g per cm2 at a distance of 15 cm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Piezoresistive cantilever array sensor for consolidated bioprocess monitoring

Cellulolytic microbes occur in diverse natural niches and are being screened for industrial modification and utility. A microbe for Consolidated bioprocessing (CBP) development can rapidly degrade pure cellulose and then ferment the resulting sugars into fuels. To identify and screen for novel microbes for CBP, we have developed a piezoresistive cantilever array sensor which is capable of simultaneous monitoring of glucose and ethanol concentration changes in a phosphate buffer solution. 4-mercaptophenylboronic acid (4-MPBA) and polyethyleneglycol (PEG)-thiol are employed to functionalize each piezoresistive cantilever for glucose and ethanol sensing, respectively. Successful concentration measurements of glucose and ethanol with minimal interferences are obtained with our cantilever array sensor.

47 OTHER INSTRUMENTATION↗

Stripping Voltammetry of Pb and Cu using a Microcantilever Electrode

Microfabricated silicon microcantilevers coated with gold on one side have been used as working electrode in a three-electrode electrochemical arrangement. In addition to electrochemical current, cantilever bending has been used as a signal for monitoring electrode reactions on the cantilever surface. The microcantilever bending was measured by an optical beam deflection method as the surface potential was scanned and electrochemical reactions occurred on the surface. The microcantilever bending due to differential surface stress was used to sense Pb and Cu using cyclic voltammetry (CV) and linear sweep stripping voltammetry (LSSV).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Standoff Spectroscopy of Surface Adsorbed Chemicals

Despite its immediate applications, selective detection of trace quantities of surface adsorbed chemicals, such as explosives, without physically collecting the sample molecules is a challenging task. Standoff spectroscopic techniques offer an ideal method of detecting chemicals without using a sample collection step. Though standoff spectroscopic techniques are capable of providing high selectivity, their demonstrated sensitivities are poor. Here we describe standoff detection of trace quantities of surface adsorbed chemicals using two quantum cascade lasers operated simultaneously, with tunable wavelength windows that match with absorption peaks of the analytes. This standoff method is a variation of photoacoustic spectroscopy, where scattered light from the sample surface is used for exciting acoustic resonance of the detector. We demonstrate a sensitivity of 100 ng/cm{sup 2} and a standoff detection distance of 20 m for surface adsorbed analytes such as explosives and tributyl phosphate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro differential thermal analysis detection of adsorbed explosive molecules using microfabricated bridges

Although micromechanical sensors enable chemical vapor sensing with unprecedented sensitivity using variations in mass and stress, obtaining chemical selectivity using the micromechanical response still remains as a crucial challenge. Chemoselectivity in vapor detection using immobilized selective layers that rely on weak chemical interactions provides only partial selectivity. Here we show that the very low thermal mass of micromechanical sensors can be used to produce unique responses that can be used for achieving chemical selectivity without losing sensitivity or reversibility. We demonstrate that this method is capable of differentiating explosive vapors from nonexplosives and is additionally capable of differentiating individual explosive vapors such as trinitrotoluene, pentaerythritol tetranitrate, and cyclotrimethylenetrinitromine. This method, based on a microfabricated bridge with a programmable heating rate, produces unique and reproducible thermal response patterns within 50 ms that are characteristic to classes of adsorbed explosive molecules. We demonstrate that this micro-differential thermal analysis technique can selectively detect explosives, providing a method for fast direct detection with a limit of detection of 600 x 10{sup -12} g.

Senesac, Larry R↗

Speciation of Energetic Materials on a Microcantilever Using Surface Reduction

Although microcantilevers have been used to detect explosives with extremely high sensitivity using variations in adsorption-induced bending and resonance frequency, obtaining selectivity remains a challenge. Reversible chemoselectivity at ambient temperatures based on receptor-based detection provides only limited selectivity due to the generality of chemical interactions. The oxygen imbalance in secondary explosives presents a means to achieve receptor-free speciation of explosives using surface reduction of adsorbed molecules. We demonstrate highly selective and real-time detection of Trinitrotoluene (TNT) using a copper oxide-coated cantilever with a surface reduction approach. Not only can this technique exclusively differentiate explosives from nonexplosives, but also it has the potential to specify individual explosives such as TNT, pentaerythritol tetranitrate (PETN), and RDX. This technique together with receptor-based detection techniques provides a multimodal approach for achieving very high selectivity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Trace Explosive Detection Using Nanosensors

Selective and sensitive detection of explosives is very important in countering terrorist threats. Detecting trace explosives has become a very complex and expensive endeavor because of a number of factors, such as the wide variety of materials that can be used as explosives, the lack of easily detectable signatures, the vast number of avenues by which these weapons can be deployed, and the lack of inexpensive sensors with high sensitivity and selectivity. High sensitivity and selectivity, combined with the ability to lower the deployment cost of sensors using mass production, is essential in winning the war on explosives-based terrorism. Nanosensors have the potential to satisfy all the requirements for an effective platform for the trace detection of explosives.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Standoff Detection of Explosive Residues Using Photothermal Microcantilevers

Standoff detection of trace explosives is gaining attention due to its immediate relevance in countering terrorist threats based on explosive devices. However, most currently available standoff techniques rely on expensive, complex, and bulky equipment. We have demonstrated highly selective and sensitive standoff detection of explosive residues on surfaces by using photothermal spectroscopy carried out with bimaterial microcantilever sensors. The demonstrated sensitivity of the technique, 100 ng/cm{sup 2}, is sufficient to detect the explosive contamination generally found on explosive devices. The sensitivity of the technique can be further improved by optimizing the bimaterial cantilever and by using higher intensity infrared sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace Explosive Detection using Photothermal Deflection Spectroscopy

Satisfying the conditions of high sensitivity and high selectivity using portable sensors that are also reversible is a challenge. Miniature sensors such as microcantilevers offer high sensitivity but suffer from poor selectivity due to the lack of sufficiently selective receptors. Although many of the mass deployable spectroscopic techniques provide high selectivity, they do not have high sensitivity. Here, we show that this challenge can be overcome by combining photothermal spectroscopy on a bimaterial microcantilever with the mass induced change in the cantilever's resonance frequency. Detection using adsorption-induced resonant frequency shift together with photothermal deflection spectroscopy shows extremely high selectivity with a subnanogram limit of detection for vapor phase adsorbed explosives, such as pentaerythritol tetranitrate (PETN), cyclotrimethylene trinitramine (RDX), and trinitrotoluene (TNT).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Standoff photo acoustic spectroscopy

Here, we demonstrate a variation of photoacoustic spectroscopy that can be used for obtaining spectroscopic information of surface adsorbed chemicals in a standoff fashion. Pulsed light scattered from a target excites an acoustic resonator and the variation of the resonance amplitude as a function of illumination wavelength yields a representation of the absorption spectrum of the target. We report sensitive and selective detection of surface adsorbed compounds such as tributyl phosphate and residues of explosives such as trinitrotoluene at standoff distances ranging from 0.5-20 m, with a detection limit on the order of 100 ng/cm{sup 2}.

Van Neste, Charles W↗